Swing moorings Sample Clauses

Swing moorings. It is the responsibility of the vessel owner to ensure their vessel is correctly secured to our swing moorings ie no chaffing points on mooring lines from vessel. Vessels are moored at theowner’s risk.
AutoNDA by SimpleDocs

Related to Swing moorings

  • Rippable Rock Rippable rock is defined as any material that can be ripped with a single-tooth hydraulic ripper drawn by a crawler tractor having a minimum draw bar pull rated at not less than 56,000 pounds (Caterpillar D-8K or equivalent) and occupies an original volume of at least one cubic yard.

  • Copper Subloops Sprint will make available access to copper subloops on an unbundled basis. A copper subloop is a portion of a Copper Loop, or Hybrid Loop, and is comprised entirely of copper wire or copper cable that acts as a transmission facility between any accessible terminal in Sprint’s outside plant, including inside wire owned or controlled by Sprint, and the end-user customer premises. A copper subloop can also include intermediate devices, such as repeaters, used to establish the transmission path. Copper subloops can be used by CLEC to provide voice-grade services as well as digital subscriber line services. Access to copper subloops is subject to the collocation provisions of this Agreement. Copper subloop consists of the distribution portion of the copper loop. Sprint is not obligated to offer feeder loop plant as a stand-alone UNE.

  • FLOORING All Bed Rooms, Dinning-cum-Living, and would be finished with Ivory Vitrified tiles (24'' X 24'') flooring and 4'' skirting. Bath-room, Kitchen & Balcony would be finished with Ivory Ceramic tiles (12'' X 12'') flooring. The walls of the Toilets/Bathrooms would finish with white glazed tiles in 60'' height. Roof would be finished with roof tiles.

  • Local Switch Usage 109.11.7.1 QPP™ Residential and Business (Per MOU) $0.00

  • Ceiling Company and its subcontractors will not affix, attach, or suspend any lighting fixtures, signs, or other fixtures or devices of any kind or nature from the ceiling above any of the Premises without the prior written approval of Authority.

  • DS3 Loop DS3 Loop is a two-point digital transmission path which provides for simultaneous two-way transmission of serial, bipolar, return-to-zero isochronous digital electrical signals at a transmission rate of 44.736 megabits per second (Mbps) that is dedicated to the use of the ordering CLEC in its provisioning of local exchange and associated exchange access services. It may provide transport for twenty-eight (28) DS1 channels, each of which provides the digital equivalent of twenty-four (24) analog voice grade channels. The interface to unbundled dedicated DS3 transport is a metallic-based electrical interface.

  • Bachelor’s Degree A four-year baccalaureate degree is recommended; however, applicants who complete a minimum of 90 semester or 135 quarter units of undergraduate study will qualify for admission. To be eligible to apply, the applicant must be on track to complete the required units through the summer term that precedes fall matriculation. Advanced Placement (AP) courses for the prerequisites will be accepted as long as the appropriate number of credit hours was received. These courses must appear on your official college transcript or in a letter from the registrar stating that the appropriate number of credit hours was verified by the program. SCCO Requirement Courses Credit Requirements Calculus MAT 351 3 semester units or 4 quarter units General Biology/Zoology (no lab required) BIO 181, 182 2 semesters (minimum of 6 semester units) or 3 quarters (minimum of 9 quarter units) General Microbiology/Bacteriology (lab required) BIO 205/205L 3 semester units or 4 quarter units General Physics (labs required) PHY 111/111L, 112/112L 2 semesters (minimum of 8 semester units) or 3 quarters (minimum of 12 quarter units) General Chemistry (labs required) CHM 113/113L, 115/115L 2 semesters (minimum of 8 semester units) or 3 quarters (minimum of 12 quarter units) Organic Chemistry (no lab required) CHM 231 3 semester units or 4 quarter units Psychology PSY 102 3 semester units or 4 quarter units English Composition or Literature ENG 105, 106 6 semester units or 8 quarter units Statistics MAT 274 3 semester units or 4 quarter units Human Anatomy* (no lab required) BIO 201 & 202 3 semester units or 4 quarter units Human Physiology* (no lab required) BIO 201 & 202 3 semester units or 4 quarter units Bio Chemistry (no lab required) CHM 360 3 semester units or 4 quarter units * Human Anatomy and Physiology lecture series may be completed one of two ways: • Combined Human A&P (6 semester units or 8 quarter units) • Separate Human Anatomy and Human Physiology (3 semester units or 4 quarter units each)

  • Addressing Objections Raised During Public Comment Period The Parties agree that the procedure contemplated for public review of this Stipulated Order and the Regional Water Board’s or its delegate’s adoption of this Stipulated Order is lawful and adequate. The Parties understand that the Regional Water Board or its delegate has the authority to require a public hearing on this Stipulated Order. If procedural objections are raised or the Regional Water Board requires a public hearing prior to the Stipulated Order becoming effective, the Parties agree to meet and confer concerning any such objections, and may agree to revise or adjust the procedure and/or this Stipulated Order as necessary or advisable under the circumstances.

  • Trench Rock Trench rock is defined as any material that must be removed from a trench that cannot be excavated with a hydraulic excavator having a bucket curling force rated at not less than 18,300 pounds (Caterpillar Model 215 or equivalent) and occupies an original volume of at least one-half cubic yard.

  • Excessive Load Company hereby agrees that it will use all paved and floor areas as constructed and in accordance with the permitted use of such areas, and Company will prohibit its Company Parties from placing excessive loads on paved or floor areas on the Premises or Common Use Areas. Company will be responsible for the repair of any paved or floor area damaged by non-conforming usage or excessive loading.

Time is Money Join Law Insider Premium to draft better contracts faster.