Unutilized Capacity Closing Statement Sample Clauses

Unutilized Capacity Closing Statement. At the Closing Date, the Company will deliver to Buyer an officers’ certificate, setting forth in detail the Unutilized Capacity under the Satellite Agreement, (i) as of the Closing Date, and (ii) as compared to the Unutilized Capacity, as of the date of the Agreement, as set forth in Section 3.27(4) of the Disclosure Schedule (the “Unutilized Capacity Closing Statement”). The Unutilized Capacity Closing Statement shall be in the form attached as Exhibit D, signed by the Chief Executive Office and the Chief Financial Officer, and accompanied by reasonable supporting documentation.
AutoNDA by SimpleDocs

Related to Unutilized Capacity Closing Statement

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.1.3.1 Definition 4.1.3.2 Notwithstanding BellSouth’s general duty to unbundle local circuit switching, BellSouth shall not be required to unbundle local circuit switching for <<customer_name>> when <<customer_name>> serves end-users with four (4) or more voice-grade (DS-0) equivalents or lines in locations served by BellSouth’s local circuit switches, which are in the following MSAs: Atlanta, GA; Miami, FL; Orlando, FL; Ft. Lauderdale, FL; Charlotte-Gastonia-Rock Hill, NC; Greensboro-Winston Salem-High Point, NC; Nashville, TN; and New Orleans, LA, and BellSouth has provided non-discriminatory cost based access to the Enhanced Extended Link (EEL) throughout Density Zone 1 as determined by NECA Tariff No. 4 as in effect on January 1, 1999. 4.1.3.3 In the event that <<customer_name>> orders local circuit switching for a single end user account name at a single physical end user location with four (4) or more 2-wire voice-grade loops from a BellSouth central office in an MSA listed above, BellSouth shall charge <<customer_name>> the market based rate in Exhibit C for use of the local circuit switching functionality for the affected facilities. 4.1.3.4 A featureless port is one that has a line port, switching facilities, and an interoffice port. A featured port is a port that includes all features then capable or a number of then capable features specifically requested by <<customer_name>>. Any features that are not currently then capable but are technically feasible through the switch can be requested through the NBR/BFR process. 4.1.3.5 BellSouth will provide to <<customer_name>> customized routing of calls: (i) to a requested directory assistance services platform; (ii) to an operator services platform pursuant to Section 10 of Attachment 2; (iii) for <<customer_name>>’s PIC’ed toll traffic in a two (2) PIC environment to an alternative OS/DA platform designated by <<customer_name>>. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers. 4.1.3.6 Remote Switching Module functionality is included in Switching Capability. The switching capabilities used will be based on the line side features they support. 4.1.3.7 Switching Capability will also be capable of routing local, intraLATA, interLATA, and calls to international customer’s preferred carrier; call features (e.g. call forwarding) and Centrex capabilities. 4.1.3.8 Where required to do so in order to comply with an effective Commission order, BellSouth will provide to <<customer_name>> purchasing local BellSouth switching and reselling BellSouth local exchange service under Attachment 1, selective routing of calls to a requested directory assistance services platform or operator services platform. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers, but obtain a <<customer_name>> branded service.

  • Under-Frequency and Over Frequency Conditions The New York State Transmission System is designed to automatically activate a load- shed program as required by the NPCC in the event of an under-frequency system disturbance. Developer shall implement under-frequency and over-frequency relay set points for the Large Generating Facility as required by the NPCC to ensure “ride through” capability of the New York State Transmission System. Large Generating Facility response to frequency deviations of predetermined magnitudes, both under-frequency and over-frequency deviations, shall be studied and coordinated with the NYISO and Connecting Transmission Owner in accordance with Good Utility Practice. The term “ride through” as used herein shall mean the ability of a Generating Facility to stay connected to and synchronized with the New York State Transmission System during system disturbances within a range of under-frequency and over-frequency conditions, in accordance with Good Utility Practice and with NPCC Regional Reliability Reference Directory # 12, or its successor.

  • Action in Shareholder Capacity Only The parties acknowledge that this Agreement is entered into by Shareholder solely in such Shareholder’s capacity as the Beneficial Owner of such Shareholder’s Owned Securities and nothing in this Agreement restricts or limits any action taken by such Shareholder in its capacity as a director or officer of the Company or any of its Affiliates and the taking of any actions (or failure to act) in its capacity as an officer or director of the Company, or any of its Affiliates, will not be deemed to constitute a breach of this Agreement, regardless of the circumstances thereto.

  • System Availability Although we will try to provide continuous access to the Service, we cannot and do not guarantee that the Service will be available 100% of the time and will not be liable in the event Service is unavailable. Actual service or network performance is dependent on a variety of factors outside of our control. If you notify us within twenty-four (24) hours and we confirm an outage consisting of a period of two (2) hours in any calendar month, and not due to any service, act, or omission of you, a third party, your applications, equipment or facilities, or reasons outside of our control, you shall be eligible for a service credit. A service credit shall be computed as a pro-rated charge for one day of the regular monthly fees for the Service in the next monthly statement. Intermittent service outages for periods of less than two (2) hours are not considered service outages. Outages caused by routine scheduled maintenance are also not considered an outage. You shall receive advance notice no less than forty-eight (48) hours in advance of our scheduled maintenance. Scheduled maintenance will be performed between 12:00 a.m. and 6:00 a.m. CST.

  • Testing Capabilities 7.2.2.10.2.1 LIS Acceptance Testing is provided where equipment is available, with the following test lines: seven-digit access to balance (100 type), milliwatt (102 type), nonsynchronous or synchronous, automatic transmission measuring (105 type), data transmission (107 type), loop-around, short circuit, open circuit, and non-inverting digital loop-back (108 type), and such other acceptance testing that may be needed to ensure that the service is operational and meets the applicable technical parameters. 7.2.2.10.2.2 In addition to LIS acceptance testing, other tests are available (e.g., additional cooperative acceptance testing, automatic scheduled testing, cooperative scheduled testing, manual scheduled testing, and non-scheduled testing). Charges for such testing are identified in Section 7.3.5.

  • SLEEPING CAPACITY/DISTURBANCES Tenant and all other occupants will be required to vacate the premises and forfeit the rental fee and security deposit for any of the following: Occupancy exceeding the sleeping capacity, using the premises for any illegal activity, causing damage to the premises rented or to any of the neighboring properties and any other acts which interfere with neighbors' right to quiet enjoyment of their premises. iTrip or the Owner, does not assume any liability for loss, damage or injury to persons or their personal property. Neither does the owner accept any liability for any inconveniences, damage, loss or injury arising from any temporary defects or stoppage in supply of water, gas, cable service, electricity or plumbing, as well as due to weather conditions, natural disasters, acts of God, or other reasons beyond its control. Tenant hereby acknowledges that the premises they have reserved may include a pool and the undersigned agrees and acknowledges that the pool and patio/deck can be dangerous areas, that the deck/patio can be slippery when wet, and that injury may occur to anyone who is not careful. With full knowledge of the above facts and warnings, the undersigned Tenant accepts and assumes all risks involved to Tenant and all of Tenant's guests in or related to the use of the community pool and patio areas.

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • DNS name server availability Refers to the ability of a public-­‐DNS registered “IP address” of a particular name server listed as authoritative for a domain name, to answer DNS queries from an Internet user. All the public DNS-­‐registered “IP address” of all name servers of the domain name being monitored shall be tested individually. If 51% or more of the DNS testing probes get undefined/unanswered results from “DNS tests” to a name server “IP address” during a given time, the name server “IP address” will be considered unavailable.

  • STRS PICK-UP The Board agrees, as a condition of employment, to tax shelter employee contributions to the State Teacher's Retirement System (STRS) in accordance with State Retirement System and Federal Internal Revenue Service guidelines and restrictions. This section in no way implies that the Board will contribute any portion of the employee's share of retirement contributions. For purposes of this paragraph, total annual salary and salary per pay period of each bargaining unit member shall be the salary otherwise payable under this Agreement, as amended. The total annual salary and salary per pay period of each member shall be payable by the Board in two parts: (1) deferred salary and (2) cash salary. A member's deferred salary shall be equal to that percentage of said member's total annual salary or salary per pay period which is required from time to time by the State Teachers Retirement System (STRS) to be paid as an employee contribution by said member as a pickup of the STRS employee contribution otherwise payable by said member. A member's cash salary shall be equal to said member's total annual salary or salary per period less the amount of the pickup for said member and shall be payable, subject to applicable payroll deductions, to said member. The Board's total combined expenditures for members' total annual salaries otherwise payable under this Agreement, as amended, (including pickup amounts) and its employer contributions to STRS shall not be greater than the amounts it would have paid for those items had this provision not been in effect. The Board shall compute and remit its employer contributions to STRS based upon total annual salary, including the "pickup". The Board shall report for Federal and Ohio income tax purposes as a member's gross income said member's total annual salary less the amount of the "pickup". The Board shall report for municipal income tax purposes as a member's gross income said member's total annual salary, including the amount of the pickup. The pickup shall be included in the member's total annual salary for the purpose of computing daily rate of pay, for determining paid salary adjustments to be made due to absence, or for any other similar purpose. The pickup shall apply to all payroll payments made after the effective date of this provision. Should the Board's payment of deferred salary cause an individual bargaining unit member's annuity contributions to exceed the IRS permissible level, any such individual shall have the right to adjust annuity deductions within thirty (30) days of the effective date of this provision.

  • Unbundled Loop Modifications (Line Conditioning 2.5.1 Line Conditioning is defined as routine network modification that BellSouth regularly undertakes to provide xDSL services to its own customers. This may include the removal of any device, from a copper Loop or copper Subloop that may diminish the capability of the Loop or Subloop to deliver high-speed switched wireline telecommunications capability, including xDSL service. Such devices include, load coils, excessive bridged taps, low pass filters, and range extenders. Excessive bridged taps are bridged taps that serves no network design purpose and that are beyond the limits set according to industry standards and/or the BellSouth’s TR 73600 Unbundled Local Loop Technical Specification. 2.5.2 BellSouth will remove load coils only on copper Loops and Subloops that are less than eighteen thousand (18,000) feet in length. 2.5.3 For any copper loop being ordered by NewPhone which has over six thousand (6,000) feet of combined bridged tap will be modified, upon request from NewPhone, so that the loop will have a maximum of six thousand (6,000) feet of bridged tap. This modification will be performed at no additional charge to NewPhone. Loop conditioning orders that require the removal of bridged tap that serves no network design purpose on a copper Loop that will result in a combined total of bridged tap between two thousand five hundred (2,500) and six thousand (6,000) feet will be performed at the rates set forth in Exhibit A. 2.5.4 NewPhone may request removal of any unnecessary and non-excessive bridged tap (bridged tap between zero (0) and two thousand five hundred (2,500) feet which serves no network design purpose), at rates pursuant to BellSouth’s SC Process as mutually agreed to by the Parties. 2.5.5 Rates for ULM are as set forth in Exhibit A. 2.5.6 BellSouth will not modify a Loop in such a way that it no longer meets the technical parameters of the original Loop type (e.g., voice grade, ADSL, etc.) being ordered. 2.5.7 If NewPhone requests ULM on a reserved facility for a new Loop order, BellSouth may perform a pair change and provision a different Loop facility in lieu of the reserved facility with ULM if feasible. The Loop provisioned will meet or exceed specifications of the requested Loop facility as modified. NewPhone will not be charged for ULM if a different Loop is provisioned. For Loops that require a DLR or its equivalent, BellSouth will provide LMU detail of the Loop provisioned. 2.5.8 NewPhone shall request Loop make up information pursuant to this Attachment prior to submitting a service inquiry and/or a LSR for the Loop type that NewPhone desires BellSouth to condition. 2.5.9 When requesting ULM for a Loop that BellSouth has previously provisioned for NewPhone, NewPhone will submit a SI to BellSouth. If a spare Loop facility that meets the Loop modification specifications requested by NewPhone is available at the location for which the ULM was requested, NewPhone will have the option to change the Loop facility to the qualifying spare facility rather than to provide ULM. In the event that BellSouth changes the Loop facility in lieu of providing ULM, NewPhone will not be charged for ULM but will only be charged the service order charges for submitting an order.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!