Utilities and Public Access Each Individual Property has rights of access to public ways and is served by water, sewer, sanitary sewer and storm drain facilities adequate to service such Individual Property for its respective intended uses. All public utilities necessary or convenient to the full use and enjoyment of each Individual Property are located either in the public right-of-way abutting such Individual Property (which are connected so as to serve such Individual Property without passing over other property) or in recorded easements serving such Individual Property and such easements are set forth in and insured by the Title Insurance Policies. All roads necessary for the use of each Individual Property for their current respective purposes have been completed and dedicated to public use and accepted by all Governmental Authorities.
Utilities and Services Tenant shall pay all charges for water, gas, ---------------------- electricity, telephone, central station monitor, refuse pickup, janitorial services, and all other utilities and services supplied or furnished to the Premises during the term of this Lease, together with any taxes thereon. Said utilities may be supplied to Tenant in common with any other tenant(s) in the Building, or at Landlord's or Tenant's option, be separately metered at Tenant's expense. If separately metered, or if the Premises consist of the entire building Tenant shall pay all such charges directly to the charging authority when due. If not separately metered, Tenant shall pay its allocable portion based upon the ratio between the Premises Gross Leasable Area and the total gross leasable square feet of space served by the common utility. However, if Landlord determines that Tenant is using a disproportionate amount of any utility service not separately metered, then Landlord may either install a separate meter to measure the utility service, at Tenant's cost, or charge Tenant a sum equal to Landlord's reasonable estimate of the cost of Tenant's excess use of such utility service. Tenant shall reimburse Landlord on a monthly basis for landlord's cost in furnishing utilities and services to the Premises within ten (10) days after Tenant receives an invoice from Landlord and in no event shall Landlord be liable to Tenant for any such failure or interruption unless caused by the misconduct of Landlord. No failure or interruption of any such utilities or services shall entitle Tenant to terminate this Lease or to withhold rent or other sums due hereunder and unless otherwise specifically provided herein. Landlord shall not be responsible for providing security guards or other security protection for all or any portion of the Premises or the Property, and Tenant shall at its own expense provide or obtain such security services as Tenant shall desire to ensure the safety of the Premises and the Property.
Use of Facilities and Services Subject to the rules of the University and the terms of this Agreement, the UFF shall have the right to use University facilities for meetings and all other services on the same basis as they are generally available to other university-related organizations which are defined as follows: University-Related Groups and Organizations. These groups and organizations may or may not receive budgetary support. Examples of such groups include student organizations, honor societies, fraternities, sororities, alumni associations, faculty committees, University Support Personnel Systems council, direct support organizations, the United Faculty of Florida, etc.
Facilities and Services The Company shall furnish the Executive with office space, secretarial and support staff, and such other facilities and services as shall be reasonably necessary for the performance of his duties under this Agreement.
Access to Information Systems Access, if any, to DXC’s Information Systems is granted solely to perform the Services under this Order, and is limited to those specific DXC Information Systems, time periods and personnel as are separately agreed to by DXC and Supplier from time to time. DXC may require Supplier’s employees, subcontractors or agents to sign individual agreements prior to access to DXC’s Information Systems. Use of DXC Information Systems during other time periods or by individuals not authorized by DXC is expressly prohibited. Access is subject to DXC business control and information protection policies, standards and guidelines as may be modified from time to time. Use of any other DXC Information Systems is expressly prohibited. This prohibition applies even when an DXC Information System that Supplier is authorized to access, serves as a gateway to other Information Systems outside Supplier’s scope of authorization. Supplier agrees to access Information Systems only from specific locations approved for access by DXC. For access outside of DXC premises, DXC will designate the specific network connections to be used to access Information Systems.
UTILITIES AND SERVICE 7.1 It is the intent of the parties that Tenant shall assume all responsibility for the operation and maintenance of the Premises. Therefore, notwithstanding anything in the Lease to the contrary, during the term of this Lease, the following utilities and services will be provided on the premises: (a) Tenant will provide Electricity, water and sewer service, since the services are billed to the Landlord, the Tenant will pay a monthly sum ( ) subject to annual review based upon the average usage the previous year. (b) The Landlord shall provide heat to such extent and to such levels as, in the Landlord’s judgment, is reasonably required for the comfortable use and occupancy of the Premises. (c) Tenant will provide landscaping and grounds keeping to the common areas and Premises. 7.2 Tenant shall, at its own costs, provide custodial and janitorial service to the Premises. 7.3 Tenant shall arrange for and shall pay the entire cost and expense of all telephone stations, equipment and use charges, electric light bulbs and all other materials and services not expressly required to be provided and paid by Landlord pursuant to the provisions of this Section 7. 7.4 Tenant shall not, without the written consent of Landlord, use any apparatus or device on the Premises (including, but without limitation thereto, electronic data processing machines, punch card machines or machines using current in excess of 110 volts) which will in any way increase the amount of electricity or water usually supplied at the Premises. Tenant shall not connect with electrical current, except through existing electrical outlets in the Premises. If Tenant requires water or electric current in excess of that usually supplied at the Premises, Tenant shall first procure the written consent of Landlord for the use thereof. Landlord may cause a water meter or electric current meter to be installed in the Premises. The cost of such meters and of installation, maintenance, and repair thereof shall be paid by Tenant. Xxxxxx further agrees to pay Landlord promptly upon demand for all such water and electric current consumed at the rates charged for such services by the City of Xxxxxxx or the local public utility, plus any additional expense incurred by Landlord in keeping account of the water and electric current so consumed. 7.5 Landlord shall not be liable for and Tenant shall not be entitled to terminate this Lease or to effectuate any abatement or reduction of rent by reason of Landlord’s failure to provide or furnish any of the foregoing utilities or services unless such failure was due to the gross negligence or intentional misconduct of Landlord. Landlord shall not be liable for loss or injury to persons or property, however arising, occurring in connection with or attributable to any failure to furnish such utilities or services, unless and only to the extent due to the gross negligence or intentional misconduct of Landlord, and in no event shall Landlord be liable for Tenant’s consequential damages. 7.6 Landlord shall be responsible for repairs of the major mechanical system, such as the boiler, HVAC and electrical system, and “Building Envelope”, such as the roof, foundation, walls and other structural components of the Building. Tenant shall be responsible for routine operation, maintenance and repairs of the Premises. A major repair to a system is one which exceeds $10,000 in a twelve month period. In the event when a major mechanical or building system failure is too costly to be repaired, if so deemed by the Landlord, and if neither Landlord or Tenant is willing or able to remedy the situation, either party can cancel this Lease. 7.7 Landlord shall not be responsible for any loss caused to Tenant by Xxxxxxxx’s failure to make any major repairs. The District’s priority and scheduling may push these repairs out several years.
Enterprise Information Management Standards Grantee shall conform to HHS standards for data management as described by the policies of the HHS Office of Data, Analytics, and Performance. These include, but are not limited to, standards for documentation and communication of data models, metadata, and other data definition methods that are required by HHS for ongoing data governance, strategic portfolio analysis, interoperability planning, and valuation of HHS System data assets.
Utilities and Appliances (1) The owner must provide all utilities needed to comply with the HQS. (2) The owner is not responsible for a breach of the HQS caused by the tenant’s failure to: (a) Pay for any utilities that are to be paid by the tenant. (b) Provide and maintain any appliances that are to be provided by the tenant.
Common Areas - Rules and Regulations Lessor or such other person(s) as Lessor may appoint shall have the exclusive control and management of the Common Areas and shall have the right, from time to time, to establish, modify, amend and enforce reasonable rules and regulations (“Rules and Regulations”) for the management, safety, care, and cleanliness of the grounds, the parking and unloading of vehicles and the preservation of good order, as well as for the convenience of other occupants or tenants of the Building and the Project and their invitees. Lessee agrees to abide by and conform to all such Rules and Regulations, and to cause its employees, suppliers, shippers, customers, contractors and invitees to so abide and conform. Lessor shall not be responsible to Lessee for the non-compliance with said Rules and Regulations by other tenants of the Project.
New Hampshire Specific Data Security Requirements The Provider agrees to the following privacy and security standards from “the Minimum Standards for Privacy and Security of Student and Employee Data” from the New Hampshire Department of Education. Specifically, the Provider agrees to: (1) Limit system access to the types of transactions and functions that authorized users, such as students, parents, and LEA are permitted to execute; (2) Limit unsuccessful logon attempts; (3) Employ cryptographic mechanisms to protect the confidentiality of remote access sessions; (4) Authorize wireless access prior to allowing such connections; (5) Create and retain system audit logs and records to the extent needed to enable the monitoring, analysis, investigation, and reporting of unlawful or unauthorized system activity; (6) Ensure that the actions of individual system users can be uniquely traced to those users so they can be held accountable for their actions; (7) Establish and maintain baseline configurations and inventories of organizational systems (including hardware, software, firmware, and documentation) throughout the respective system development life cycles; (8) Restrict, disable, or prevent the use of nonessential programs, functions, ports, protocols, and services; (9) Enforce a minimum password complexity and change of characters when new passwords are created; (10) Perform maintenance on organizational systems; (11) Provide controls on the tools, techniques, mechanisms, and personnel used to conduct system maintenance; (12) Ensure equipment removed for off-site maintenance is sanitized of any Student Data in accordance with NIST SP 800-88 Revision 1; (13) Protect (i.e., physically control and securely store) system media containing Student Data, both paper and digital; (14) Sanitize or destroy system media containing Student Data in accordance with NIST SP 800-88 Revision 1 before disposal or release for reuse; (15) Control access to media containing Student Data and maintain accountability for media during transport outside of controlled areas; (16) Periodically assess the security controls in organizational systems to determine if the controls are effective in their application and develop and implement plans of action designed to correct deficiencies and reduce or eliminate vulnerabilities in organizational systems; (17) Monitor, control, and protect communications (i.e., information transmitted or received by organizational systems) at the external boundaries and key internal boundaries of organizational systems; (18) Deny network communications traffic by default and allow network communications traffic by exception (i.e., deny all, permit by exception); (19) Protect the confidentiality of Student Data at rest; (20) Identify, report, and correct system flaws in a timely manner; (21) Provide protection from malicious code (i.e. Antivirus and Antimalware) at designated locations within organizational systems; (22) Monitor system security alerts and advisories and take action in response; and (23) Update malicious code protection mechanisms when new releases are available.