Wall Systems. All interior walls, except restrooms, shall be painted or vinyl covered drywall or field applied vinyl covered 5/8” gypsum board. Vinyl fabric shall be medium weight, textured, wall covering with stain resistant surface coatings. 4” vinyl base shall be applied to all walls. Metal studs, floor and ceiling track shall be 20 gauge galvanized steel spaced at 16” O.C. (24” O.C. not acceptable). Gypsum board fasteners shall be drywall screws not less than 1 – ¼” long. Painted surfaces shall receive 1 coat of primer and 2 coats of finish. A complete room finish schedule shall be submitted for approval by the Lessee prior to construction. Colors shall be selected by the State. Gypsum board allowance: provide 1 linear foot of gypsum drywall board partition (finished on each side) for each 25 square feet of space rented referenced in Article I of the Lease. Exterior wall insulation is to be covered from floor to roof deck with 5/8” gypsum board as noted above. Gypsum board above the acoustic ceiling line may be unfinished. Walls in restrooms shall be finished with glazed wall tile extending from floor to 6’ – 0” AFF. Tile shall be standard grade meeting ANSI 137.1

Appears in 21 contracts

Samples: www.michigan.gov, 169.62.82.226, www.michigan.gov

AutoNDA by SimpleDocs

Wall Systems. All interior walls, except restrooms, shall be painted or vinyl covered drywall or field applied vinyl covered 5/8” gypsum board. Vinyl fabric shall be medium weight, textured, wall covering with stain resistant surface coatings. 4” vinyl base shall be applied to all walls. Metal studs, floor and ceiling track shall be 20 gauge galvanized steel spaced at 16” O.C. (24” O.C. not acceptable). Gypsum board fasteners shall be drywall screws not less than 1 – ¼” long. Painted surfaces shall receive 1 coat of primer and 2 coats of finish. A complete room finish schedule shall be submitted for approval by the Lessee prior to construction. Colors shall be selected by the State. Provide clear plastic guards up to 60” AFF on all outside corners to protect vinyl wall covering. Gypsum board allowance: provide 1 linear foot of gypsum drywall board partition (finished on each side) for each 25 square feet of space rented referenced in Article I of the Lease. Exterior wall insulation is to be covered from floor to roof deck with 5/8” gypsum board as noted above. Gypsum board above the acoustic ceiling line may be unfinished. Walls in restrooms shall be finished with glazed wall tile extending from floor to 6’ – 0” AFF. Tile shall be standard grade meeting ANSI 137.1

Appears in 1 contract

Samples: www.michigan.gov

AutoNDA by SimpleDocs
Time is Money Join Law Insider Premium to draft better contracts faster.