Xxxxxxxx Substation. As depicted in Figure A-1, the Network Upgrade Facilities at Connecting Transmission Owner’s Xxxxxxxx Substation include the following major electrical and physical equipment: • Replacement of the conductor from the overhead incoming line to disconnect switch 123 (DS123) with 1192 ACSR 45/7 Xxxxxxx conductor (or two (2) 795 MCM cables for ease of installation); • Replacement of the incoming line connections to disconnect switches 13 and 23 (DS13 and DS23) with 1192 ACSR 45/7 Xxxxxxx conductor (or two (2) 795 MCM cables for ease of installation); • Upgrade of the wave traps on Line 2 and Line 12 from 1200A to 1600A, and replacement of the associated coupling capacitors; The system protection modifications at the Xxxxxxxx Substation include: Special Protection Scheme (“SPS”) • Installation of: o An Alstom DIP 5000 relay for the SPS; o Two (2) SEL 351-6 relays (one on breaker R10 and one on breaker R20) to provide the primary SPS input to the DIP 5000; and o Two (2) ERLPhase F-Pro-4000 relays (one on breaker R10 and one on breaker R20) to provide the secondary SPS input to the DIP 5000. SERVICE AGREEMENT NO. 2472 o Modification of the SPS logic at Xxxxxxxx Substation to treat separately the opening of R10 and R20 and the opening of R120 or Alcoa’s Substation’s circuit breaker R8105. Line Reconductoring • Update Line 12 step-distance relay settings.

Appears in 3 contracts

Samples: Joint Amended and Restated Transmission Project Interconnection Agreement, Joint Amended and Restated Transmission Project Interconnection Agreement, Joint Amended and Restated Transmission Project Interconnection Agreement

AutoNDA by SimpleDocs

Xxxxxxxx Substation. As depicted in Figure A-1, the Network Upgrade Facilities at Connecting Transmission Owner’s Xxxxxxxx Substation include the following major electrical and physical equipment: • Replacement of the conductor from the overhead incoming line to disconnect switch 123 (DS123) with 1192 ACSR 45/7 Xxxxxxx conductor (or two (2) 795 MCM cables for ease of installation); • Replacement of the incoming line connections to disconnect switches 13 and 23 (DS13 and DS23) with 1192 ACSR 45/7 Xxxxxxx conductor (or two (2) 795 MCM cables for ease of installation); • Upgrade of the wave traps on Line 2 and Line 12 from 1200A to 1600A, and replacement of the associated coupling capacitors; The system protection modifications at the Xxxxxxxx Substation include: Special Protection Scheme (“SPS”) • Installation of: o An Alstom DIP 5000 relay for the SPS; o Two (2) SEL 351-6 relays (one on breaker R10 and one on breaker R20) to provide the primary SPS input to the DIP 5000; and o Two (2) ERLPhase FXXXXxxxx X-Pro-4000 Xxx-0000 relays (one on breaker R10 and one on breaker R20) to provide the secondary SPS input to the DIP 5000. SERVICE AGREEMENT NO. 2472 o Modification of the SPS logic at Xxxxxxxx Substation to treat separately the opening of R10 and R20 and the opening of R120 or Alcoa’s Substation’s circuit breaker R8105. Line Reconductoring • Update Line 12 step-distance relay settings.

Appears in 1 contract

Samples: Transmission Project Interconnection Agreement

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!