Additional Physical Design Specifications. Licensee’s Facilities placed in AT&T’s Conduit System must meet all of the following physical design specifications: 3.4.1 Cables bound or wrapped with cloth or having any kind of fibrous coverings or impregnated with an adhesive material shall not be placed in AT&T’s Conduit or Ducts. 3.4.2 The integrity of AT&T’s Conduit System and overall safety of AT&T’s personnel and other personnel working in AT&T’s Conduit System requires that “dielectric cable” be required when Licensee’s cable Facility utilizes an alternative Duct or route that is shared in the same trench by any current carrying Facility of a power utility. 3.4.3 New construction splices in Licensee’s fiber optic and twisted pair cables shall be located in Manholes, pull boxes or Handholes.
Appears in 2 contracts
Samples: License Agreement, Rights of Way (Row), Conduits, and Pole Attachments Agreement
Additional Physical Design Specifications. Licensee’s Facilities placed in AT&T’s Conduit System must meet all of the following physical design specifications:
3.4.1 Cables bound or wrapped with cloth or having any kind of fibrous coverings or impregnated with an adhesive material shall not be placed in AT&T’s Conduit or Ducts.
3.4.2 The integrity of AT&T’s Conduit System and Systemand overall safety of AT&T’s personnel and other personnel working in AT&T’s Conduit System requires that “dielectric cable” be required when Licensee’s cable Facility utilizes an alternative Duct or route that is shared in the same trench by any current carrying Facility of a power utility.
3.4.3 New construction splices in Licensee’s fiber optic and twisted pair cables shall be located in Manholes, pull boxes or Handholes.
Appears in 1 contract
Samples: Interconnection Agreement
Additional Physical Design Specifications. Licensee’s 's Facilities placed in AT&T’s 's Conduit System must meet all of the following physical design specifications:
3.4.1 Cables bound or wrapped with cloth or having any kind of fibrous coverings or impregnated with an adhesive material shall not be placed in AT&T’s 's Conduit or Ducts.
3.4.2 The integrity of AT&T’s 's Conduit System and overall safety of AT&T’s 's personnel and other personnel working in AT&T’s 's Conduit System requires that “"dielectric cable” " be required when Licensee’s 's cable Facility utilizes an alternative Duct or route that is shared in the same trench by any current carrying Facility of a power utility.
3.4.3 New construction splices in Licensee’s 's fiber optic and twisted pair cables shall be located in Manholes, pull boxes or Handholes.