Compression. Producer shall provide Gatherer with a minimum of thirty (30) Days’ notice before any new compression is to be installed. Any compression installed by Producer upstream of a Receipt Point shall: (1) not be within 400 feet of any measurement site of the Gathering System; (2) minimize pulsation at the Interconnect Facilities, at a square root error below zero point five percent (0.5%) (based on an industry-accepted square root indicator); (3) have low-pressure shutdown controls on the suction system that prevent drawing air into the system and, to the extent Producer desires to operate the suction system with less than a two (2) Psig minimum inlet pressure, an oxygen sensor shall be installed on the inlet of the suction line so as to automatically shut down Producer’s Compression Facilities when the oxygen is detected at levels above two thousand (2,000) parts per million (0.2%); and (4) be operated such that the discharge/outlet line pressure measured at the compressor cylinder shall not exceed the MAOP of the Gathering System downstream of the Interconnect Facilities (with Producer responsible for primary pressure cut).
Appears in 3 contracts
Samples: Gas Gathering Agreement, Gas Gathering Agreement (EQT Midstream Partners, LP), Gas Gathering Agreement (EQT Midstream Partners, LP)
Compression. Producer shall provide Gatherer with a minimum of thirty (30) Days’ notice before any new compression is to be installed. Any compression installed by Producer upstream of a Receipt Point shall: (1) not be within 400 feet of any measurement site of the Gathering System; (2) minimize pulsation at the Interconnect Facilities, at a square root error below zero point five percent (0.5%) (based on an industry-accepted square root indicator); (3) have low-pressure shutdown controls on the suction system that prevent drawing air into the system and, to the extent Producer desires to operate the suction system with less than a two (2) Psig psig minimum inlet pressure, an oxygen sensor shall be installed on the inlet of the suction line so as to automatically shut down Producer’s the Producer Compression Facilities when the oxygen is detected at levels above two thousand (2,000) parts per million (0.2%); and (4) be operated such that the discharge/outlet line pressure measured at the compressor cylinder shall not exceed the MAOP maximum allowable operating pressure of the Gathering System downstream of the Interconnect Facilities (with Producer responsible for primary pressure cut).
Appears in 1 contract
Samples: Gas Gathering Agreement (EQT Midstream Partners, LP)