We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.

For more information visit our privacy policy.

Common use of Description of Service Clause in Contracts

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 3 contracts

Samples: Telecommunications, Telecommunications, Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> SouthEast loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> SouthEast ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU SouthEast with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by SouthEast for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by SouthEast and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> SouthEast as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing SouthEast to determine whether, in SouthEast’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECSouthEast wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> SouthEast may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, SouthEast shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided SouthEast bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. SouthEast bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with SouthEast's equipment for accomplishing SouthEast's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> SouthEast is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 3 contracts

Samples: Clec Agreement, Clec Agreement, Clec Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> Southern Telecom LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Southern Telecom can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Southern Telecom intends to install and the services <<customer_short_name>> Southern Telecom wishes to provide. This section addresses LMU is as a preordering transaction, distinct from <<customer_short_name>> Southern Telecom ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Southern Telecom LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Southern Telecom as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA Letter of Authorization (LOA) from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Southern Telecom may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> Southern Telecom and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>Southern Telecom’s ability to provide advanced data services over the ordered Loop type. FurthermoreFurther, if Southern Telecom orders Loops that do not require a specific facility medium (i.e. copper only) or Loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible Loops) and that are not inventoried as advanced services Loops, the LMU information for such Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Southern Telecom is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 3 contracts

Samples: Interconnection Agreement, Interconnection Agreement, Clec Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> BTI loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> BTI ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU BTI with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by BTI for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by BTI and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> BTI as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing BTI to determine whether, in BTI’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECBTI wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> BTI may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, BTI shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided BTI bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. BTI bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with BTI's equipment for accomplishing BTI's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end- user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> BTI is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> DSL Telecom loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> DSL Telecom ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU DSL Telecom with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by DSL Telecom for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by DSL Telecom and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> DSL Telecom as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing DSL Telecom to determine whether, in DSL Telecom’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECDSL Telecom wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> DSL Telecom may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, DSL Telecom shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided DSL Telecom bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. DSL Telecom bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with DSL Telecom's equipment for accomplishing DSL Telecom's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> DSL Telecom is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> LMU Comm South (LMU) information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Comm South can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Comm South intends to install and the services <<customer_short_name>> Comm South wishes to provide. This section addresses LMU is as a preordering transaction, distinct from <<customer_short_name>> Comm South ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Comm South LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Comm South as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for on facilities is contingent upon either BellSouth or the requesting CLEC controlling owning the Loop(sloop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled owned by another CLEC unless BellSouth receives a LOA Letter of Authorization (LOA) from the voice CLEC (owner) or its authorized agent on the LMUSI (Loop Makeup Service Inquiry) submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Comm South may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth networkLoop. The determination shall be made solely by <<customer_short_name>> Comm South and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>Comm South’s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, if Comm South orders loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible loops) and that are not inventoried as advanced services loops, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, such loops is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Comm South is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Clec Agreement, Clec Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Xspedius loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Xspedius ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Xspedius with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Xspedius for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Xspedius and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Xspedius as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Xspedius to determine whether, in Xspedius’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECXspedius wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Xspedius may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Xspedius shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Xspedius bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Xspedius bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Xspedius's equipment for accomplishing Xspedius's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Xspedius is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement Amendment

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> CLEC-1 loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> CLEC-1 ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU CLEC-1 with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by CLEC-1 for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by CLEC-1 and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> CLEC-1 as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing CLEC-1 to determine whether, in CLEC-1’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECCLEC-1 wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> CLEC-1 may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, CLEC-1 shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided CLEC-1 bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. CLEC-1 bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with CLEC-1's equipment for accomplishing CLEC-1's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> CLEC-1 is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Clec Agreement, Clec Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> NOW loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> NOW ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU NOW with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by NOW for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by NOW and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> NOW as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing NOW to determine whether, in NOW’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECNOW wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> NOW may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, NOW shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided NOW bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. NOW bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with NOW's equipment for accomplishing NOW's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> NOW is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Bellsouth® / Clec Agreement, Telecommunications

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> Xxxx LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Xxxx can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Xxxx intends to install and the services <<customer_short_name>> Xxxx wishes to provide. This section addresses LMU is as a preordering transaction, distinct from <<customer_short_name>> Xxxx ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Xxxx LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-pair- gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Xxxx as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA Letter of Authorization (LOA) from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Xxxx may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> Xxxx and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>’s Xxxx’x ability to provide advanced data services over the ordered Loop type. FurthermoreFurther, if Xxxx orders Loops that do not require a specific facility medium (i.e. copper only) or Loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible Loops) and that are not inventoried as advanced services Loops, the LMU information for such Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Xxxx is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_namecustomer_name>> LMU (LMU) information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_namecustomer_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_namecustomer_name>> intends to install and the services <<customer_short_namecustomer_name>> wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_namecustomer_name>> LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_namecustomer_name>> as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_namecustomer_name>> may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth networkLoop. The determination shall be made solely by <<customer_short_namecustomer_name>> and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved loop requested taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_namecustomer_name>>’s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, if <<customer_name>> orders loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible loops) and that are not inventoried as advanced services loops, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, such loops is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_namecustomer_name>> is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> CBX One-Stop LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> CBX One-Stop can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> CBX One-Stop intends to install and the services <<customer_short_name>> CBX One-Stop wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> CBX One-Stop ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> CBX One-Stop LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> CBX One-Stop as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> CBX One-Stop may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> CBX One-Stop and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>CBX One-Stop’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-UCL- ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> CBX One-Stop or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> CBX One-Stop is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>CBX One-Stop, according to the applicable network disclosure requirements. It will be <<customer_short_name>>CBX One- Stop’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> CBX One-Stop fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Choctaw loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Choctaw ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Choctaw with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Choctaw for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Choctaw and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Choctaw as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Choctaw to determine whether, in Choctaw’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECChoctaw wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Choctaw may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Choctaw shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Choctaw bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Choctaw bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Choctaw's equipment for accomplishing Choctaw's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Choctaw is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> LMU AirCover Network Solutions, Inc. (LMU) information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> AirCover Network Solutions, Inc. can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> AirCover Network Solutions, Inc. intends to install and the services <<customer_short_name>> AirCover Network Solutions, Inc. wishes to provide. This section addresses LMU is as a preordering transaction, distinct from <<customer_short_name>> AirCover Network Solutions, Inc. ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> AirCover Network Solutions, Inc. LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> AirCover Network Solutions, Inc. as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> AirCover Network Solutions, Inc. may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth networkLoop. The determination shall be made solely by <<customer_short_name>> AirCover Network Solutions, Inc. and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>AirCover Network Solutions, Inc.’s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, if AirCover Network Solutions, Inc. orders loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible loops) and that are not inventoried as advanced services loops, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, such loops is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6AirCover Network Solutions, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Inc. is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.4.1.1 BellSouth shall make available to <<customer_short_name>> KMC Telecom loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> KMC Telecom ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.4.1.2 BellSouth will provide <<customer_short_name>> LMU KMC Telecom with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by KMC Telecom for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by KMC Telecom and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.4.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> KMC Telecom as it i t exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.4.1.4 BellSouth offers LMU information for the sole purpose of allowing KMC Telecom to determine whether, in KMC Telecom’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECKMC Telecom wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> KMC Telecom may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, KMC Telecom shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided KMC Telecom bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. KMC Telecom bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with KMC Telecom's equipment for accomplishing KMC Telecom's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> KMC Telecom is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> E-Z Access loop makeup (LMU) data for BellSouth’s network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> E-Z Access ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU E-Z Access with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by E-Z Access for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by E-Z Access and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> E-Z Access as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing E-Z Access to determine whether, in E-Z Access’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECE-Z Access wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> E-Z Access may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, E-Z Access shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided E-Z Access bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. E-Z Access bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with E-Z Access's equipment for accomplishing E-Z Access's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copperE-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Z Access is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> NAS loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> NAS ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU NAS with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by NAS for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by NAS and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> NAS as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing NAS to determine whether, in NAS’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECNAS wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> NAS may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, NAS shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided NAS bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. NAS bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with NAS's equipment for accomplishing NAS's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> NAS is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> API loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> API ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU API with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by API for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by API and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> API as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing API to determine whether, in API’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECAPI wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> API may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, API shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided API bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. API bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with API's equipment for accomplishing API's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end- user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> API is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> FeroNetworks LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> FeroNetworks can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> FeroNetworks intends to install and the services <<customer_short_name>> FeroNetworks wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> FeroNetworks ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> FeroNetworks LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> FeroNetworks as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> FeroNetworks may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> FeroNetworks and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>FeroNetworks’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-UCL- ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> FeroNetworks or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> FeroNetworks is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>FeroNetworks, according to the applicable network disclosure requirements. It will be <<customer_short_name>>FeroNetworks’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> FeroNetworks fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> New Access loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> New Access ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU New Access with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by New Access for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by New Access and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> New Access as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing New Access to determine whether, in New Access’ judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECNew Access wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> New Access may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, New Access shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided New Access bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. New Access bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with New Access’ equipment for accomplishing New Access’ end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> New Access is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> Xxxxxxx Telephone LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Xxxxxxx Telephone can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Xxxxxxx Telephone intends to install and the services <<customer_short_name>> Xxxxxxx Telephone wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> Xxxxxxx Telephone ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Xxxxxxx Telephone LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Xxxxxxx Telephone as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Xxxxxxx Telephone may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> Xxxxxxx Telephone and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>Xxxxxxx Telephone’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-UCL- ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> Xxxxxxx Telephone or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Xxxxxxx Telephone is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>Xxxxxxx Telephone, according to the applicable network disclosure requirements. It will be <<customer_short_name>>Xxxxxxx Telephone’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> Xxxxxxx Telephone fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> ALLTEL loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> ALLTEL ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU ALLTEL with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by ALLTEL for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by ALLTEL and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> ALLTEL as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing ALLTEL to determine whether, in ALLTEL’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECALLTEL wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> ALLTEL may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, ALLTEL shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided ALLTEL bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. ALLTEL bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with ALLTEL's equipment for accomplishing ALLTEL's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> ALLTEL is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Edge Connections loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Edge Connections ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Edge Connections with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Edge Connections for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Edge Connections and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Edge Connections as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Edge Connections to determine whether, in Edge Connections’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECEdge Connections wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Edge Connections may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Edge Connections shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Edge Connections bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Edge Connections bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Edge Connections's equipment for accomplishing Edge Connections's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Edge Connections is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Broadslate loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Broadslate ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Broadslate with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Broadslate for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Broadslate and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Broadslate as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Broadslate to determine whether, in Broadslate’s judgment, XxxxXxxxx's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECBroadslate wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Broadslate may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Broadslate shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Broadslate bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Broadslate bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Broadslate's equipment for accomplishing Broadslate's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Broadslate is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> LCT loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> LCT ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU LCT with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by LCT for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by LCT and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> LCT as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing LCT to determine whether, in LCT’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECLCT wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> LCT may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, LCT shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided LCT bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. LCT bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with LCT's equipment for accomplishing LCT's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> LCT is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Rhythms loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Rhythms ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Rhythms with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Rhythms for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Rhythms and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Rhythms as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Rhythms to determine whether, in Rhythms’ judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECRhythms wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Rhythms may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Rhythms shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Rhythms bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Rhythms bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Rhythms’ equipment for accomplishing Rhythms’ end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Rhythms is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> Columbus Local LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Columbus Local can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Columbus Local intends to install and the services <<customer_short_name>> Columbus Local wishes to provide. This section addresses LMU is as a preordering transaction, distinct from <<customer_short_name>> Columbus Local ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Columbus Local LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Columbus Local as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Columbus Local may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth networkLoop. The determination shall be made solely by <<customer_short_name>> Columbus Local and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>Columbus Local’s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, if Columbus Local orders loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible loops) and that are not inventoried as advanced services loops, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, such loops is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Columbus Local is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> MRC loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> MRC ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU MRC with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by MRC for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by MRC and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> MRC as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing MRC to determine whether, in MRC’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECMRC wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> MRC may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, MRC shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided MRC bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. MRC bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with MRC's equipment for accomplishing MRC's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> MRC is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Global Crossing loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Global Crossing ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Global Crossing with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Global Crossing for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Global Crossing and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Global Crossing as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Global Crossing to determine whether, in Global Crossing’s judgment, XxxxXxxxx's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECGlobal Crossing wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Global Crossing may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Global Crossing shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Global Crossing bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Global Crossing bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Global Crossing's equipment for accomplishing Global Crossing's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Global Crossing is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> EPB Telecommunications loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> EPB Telecommunications ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU EPB Telecommunications with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by EPB Telecommunications for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by EPB Telecommunications and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> EPB Telecommunications as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing EPB Telecommunications to determine whether, in EPB Telecommunications' judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECEPB Telecommunications wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> EPB Telecommunications may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, EPB Telecommunications shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided EPB Telecommunications bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. EPB Telecommunications bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with EPB Telecommunications' equipment for accomplishing EPB Telecommunications' end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> EPB Telecommunications is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Wakul loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Wakul ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Wakul with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Wakul for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Xxxxx and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Wakul as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Wakul to determine whether, in Xxxxx’s judgment, XxxxXxxxx's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECWakul wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Wakul may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Wakul shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Wakul bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Wakul bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Xxxxx's equipment for accomplishing Wakul's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Wakul is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> Rent-A-Line LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Rent-A- Line can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Rent-A-Line intends to install and the services <<customer_short_name>> Rent-A-Line wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> Rent-A-Line ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Rent-A-Line LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Rent-A-Line as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Rent-A-Line may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> Rent-A-Line and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>Rent-A-Line’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-UCL- ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> Rent-A-Line or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Rent-A-Line is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>Rent-A-Line, according to the applicable network disclosure requirements. It will be <<customer_short_name>>Rent-A- Line’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> Rent-A-Line fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.10.1.1 BellSouth shall make available to <<customer_short_name>> CTES loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> CTES ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.10.1.2 BellSouth will provide <<customer_short_name>> LMU CTES with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by CTES for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by CTES and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.10.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> CTES as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.10.1.4 BellSouth offers LMU information for the sole purpose of allowing CTES to determine whether, in CTES’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECCTES wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> CTES may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, CTES shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided CTES bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. CTES bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with CTES's equipment for accomplishing CTES's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> CTES is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> aXessa loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> aXessa ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU aXessa with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by aXessa for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by aXessa and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> aXessa as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing aXessa to determine whether, in aXessa’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECaXessa wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> aXessa may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, aXessa shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided aXessa bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. aXessa bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with aXessa's equipment for accomplishing aXessa's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> aXessa is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Navigator loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Navigator ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Navigator with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Navigator for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Navigator and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information informa tion is provided to <<customer_short_name>> Navigator as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Navigator to determine whether, in Navigator’s judgment, XxxxXxxxx's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECNavigator wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Navigator may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Navigator shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Navigator bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Navigator bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Navigator's equipment for accomplishing Navigator's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Navigator is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Arrow loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Arrow ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Arrow with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Arrow for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Arrow and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Arrow as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Arrow to determine whether, in Arrow’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECArrow wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Arrow may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Arrow shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Arrow bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Arrow bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Arrow's equipment for accomplishing Arrow's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Arrow is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.8.1.1 BellSouth shall make available to <<customer_short_name>> NewSouth loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> NewSouth ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.8.1.2 BellSouth will provide <<customer_short_name>> LMU NewSouth with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by NewSouth for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by NewSouth and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.8.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> NewSouth as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.8.1.4 BellSouth offers LMU information for the sole purpose of allowing NewSouth to determine whether, in NewSouth’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECNewSouth wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> NewSouth may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, NewSouth shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided NewSouth bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. NewSouth bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with NewSouth's equipment for accomplishing NewSouth's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> NewSouth is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> NTERA, INC. loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> NTERA, INC. ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU NTERA, INC. with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by NTERA, INC. for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by NTERA, INC. and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> NTERA, INC. as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing NTERA, INC. to determine whether, in NTERA, INC.’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECNTERA, INC. The requesting CLEC is not authorized wishes to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> provide over those loops. NTERA, INC. may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, NTERA, INC. shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided NTERA, INC. bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. NTERA, INC. bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with NTERA, INC.'s equipment for accomplishing NTERA, INC.'s end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). FurthermoreNTERA, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s networkINC. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> LS-One loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> LS-One ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU LS-One with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by LS-One for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by LS-One and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> LS-One as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing LS-One to determine whether, in LS-One’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECLS-One wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> LS-One may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, LS-One shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided LS-One bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. LS-One bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with LS-One's equipment for accomplishing LS-One's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copperLS-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> One is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Actel loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Actel ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Actel with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Actel for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Actel and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Actel as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Actel to determine whether, in Actel’s judgment, XxxxXxxxx's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECActel wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Actel may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Actel shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Actel bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Actel bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Actel's equipment for accomplishing Actel's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Actel is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> 1-800-RECONEX LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> 1-800-RECONEX can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> 1-800-RECONEX intends to install and the services <<customer_short_name>> 1-800-RECONEX wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> 1-800-RECONEX ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> 1-800-RECONEX LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> 1-800-RECONEX as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> 2.9.1. 5 1-800-RECONEX may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> 1-800-RECONEX and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>1-800-RECONEX’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-UCL- ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> 1-800-RECONEX or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> 1-800-RECONEX is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> LMU VarTec (LMU) information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> VarTec can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> VarTec intends to install and the services <<customer_short_name>> VarTec wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> VarTec LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-pair- gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> VarTec as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> VarTec may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth networkLoop. The determination shall be made solely by <<customer_short_namecustomer_name>> and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved loop requested taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>VarTec’s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, if VarTec orders loops that are not intended to support advanced services (such as UV-SL1, UV- SL2, or ISDN compatible loops) and that are not inventoried as advanced services loops, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, such loops is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> VarTec is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> ZNC loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> ZNC ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU ZNC with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by ZNC for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by ZNC and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> ZNC as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing ZNC to determine whether, in ZNC’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECZNC wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> ZNC may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, ZNC shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided ZNC bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. ZNC bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with ZNC's equipment for accomplishing ZNC's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end- user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> ZNC is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> LINEDRIVE loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> LINEDRIVE ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU LINEDRIVE with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by LINEDRIVE for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by LINEDRIVE and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> LINEDRIVE as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing LINEDRIVE to determine whether, in LINEDRIVE’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECLINEDRIVE wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> LINEDRIVE may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, LINEDRIVE shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided LINEDRIVE bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. LINEDRIVE bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with LINEDRIVE's equipment for accomplishing LINEDRIVE's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> LINEDRIVE is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> Xxxx Communications loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> Xxxx Communications ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU Xxxx Communications with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by Xxxx Communications for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by Xxxx Communications and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Xxxx Communications as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing Xxxx Communications to determine whether, in Xxxx Communications’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECXxxx Communications wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Xxxx Communications may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, Xxxx Communications shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided Xxxx Communications bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. Xxxx Communications bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with Xxxx Communications's equipment for accomplishing Xxxx Communications's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end- user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Xxxx Communications is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 BellSouth shall make available to <<customer_short_name>> Clearwave Communications LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> Clearwave Communications can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> Clearwave Communications intends to install and the services <<customer_short_name>> Clearwave Communications wishes to provide. LMU is a preordering transaction, distinct from <<customer_short_name>> Clearwave Communications ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.9.1.2 BellSouth will provide <<customer_short_name>> Clearwave Communications LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.9.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> Clearwave Communications as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> Clearwave Communications may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does not disrupt other services on the BellSouth network. The determination shall be made solely by <<customer_short_name>> Clearwave Communications and BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee <<customer_short_name>>Clearwave Communications’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> Clearwave Communications or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Clearwave Communications is fully responsible for any of its service configurations that may differ from BellSouth’s technical standard for the Loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>Clearwave Communications, according to the applicable network disclosure requirements. It will be <<customer_short_name>>Clearwave Communications’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> Clearwave Communications fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> E-Tel loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> E-Tel ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU E-Tel with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by E-Tel for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by E-Tel and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> E-Tel as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing E-Tel to determine whether, in E-Tel’s judgment, BellSouth's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECE-Tel wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> E-Tel may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, E-Tel shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided E-Tel bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. E-Tel bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with E-Tel's equipment for accomplishing E-Tel's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copperE-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> Tel is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.9.1.1 2.14.1.1 BellSouth shall make available to <<customer_short_name>> API loop makeup (LMU) data for BellSouth's network facilities. This section addresses LMU information with respect to Loops that are required to be unbundled under this Agreement so that <<customer_short_name>> can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment <<customer_short_name>> intends to install and the services <<customer_short_name>> wishes to provide. LMU is as a preordering transaction, distinct from <<customer_short_name>> API ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.9.1.2 2.14.1.2 BellSouth will provide <<customer_short_name>> LMU API with loop makeup information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devicesdevises, feeder/distribution interfaces, bridged bridge taps, load coils, pair-gain devices; the Loop loop length; and the wire gauge gauge. The LMUSI may be utilized by API for the purpose of determining whether the loop requested is capable of supporting DSL service or other advanced data services. The determination shall be made solely by API and electrical parametersBellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said loop. 2.9.1.3 2.14.1.3 BellSouth’s LMU information is provided to <<customer_short_name>> API as it exists either in BellSouth's databases or in its hard copy facility records. BellSouth does not guarantee accuracy or reliability of the LMU information provided. 2.9.1.4 BellSouth’s provisioning of 2.14.1.4 BellSouth offers LMU information for the sole purpose of allowing API to determine whether, in API’s judgment, XxxxXxxxx's loops will support the requesting CLEC for facilities is contingent upon either BellSouth or the requesting CLEC controlling the Loop(s) specific services that serve the service location for which LMU information has been requested by the CLECAPI wishes to provide over those loops. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless BellSouth receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. 2.9.1.5 <<customer_short_name>> API may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular BellSouth Loop as long as that equipment does loop; however, such configurations may not disrupt other services on match BellSouth's or the BellSouth networkindustry’s standards and specifications for the intended type and level of service. The determination Accordingly, API shall be made solely by <<customer_short_name>> and BellSouth shall not be liable in any way responsible for insuring that the performance of the advanced data services provisioned over said Loop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match matches the LMU of the Loop reserved taking into consideration any requisite line conditioningfacility requested. The LMU data is provided API bears full responsibility for informational purposes only being knowledgeable of BellSouth's technical standards and does not guarantee <<customer_short_name>>’s ability the specifications of BellSouth's loops. API bears full responsibility for making the appropriate ordering decisions of matching BellSouth loops with API's equipment for accomplishing API's end goal for the intended service it wishes to provide advanced data services over the ordered Loop typeits end-user(s). Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to BellSouth’s network. Except as set forth in Section 2.9.1.6, copper-only Loops will not be subject to change due to modification and/or upgrades to BellSouth’s network and will remain on copper facilities until the Loop is disconnected by <<customer_short_name>> or the End User, or until BellSouth retires the copper facilities via the FCC’s and any applicable Commission’s requirements. <<customer_short_name>> API is fully responsible for any of its service configurations that may differ from BellSouth’s 's technical standard for the Loop loop type ordered. 2.9.1.6 If BellSouth retires its copper facilities using 47 C.F.R § 52.325(a) requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, BellSouth will notify <<customer_short_name>>, according to the applicable network disclosure requirements. It will be <<customer_short_name>>’s responsibility to move any service it may provide over such facilities to alternative facilities. If <<customer_short_name>> fails to move the service to alternative facilities by the date in the network disclosure notice, BellSouth may terminate the service to complete the network change.

Appears in 1 contract

Samples: Interconnection Agreement