We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.

For more information visit our privacy policy.

Common use of Description of Service Clause in Contracts

Description of Service. 2.21.1.1 AT&T shall make available to TWTC LMU information with respect to Loops that are required to be unbundled under this Agreement so that TWTC can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment TWTC intends to install and the services TWTC wishes to provide. LMU is a preordering transaction, distinct from TWTC ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.21.1.2 AT&T will provide TWTC LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair- gain devices; the Loop length; the wire gauge and electrical parameters. 2.21.1.3 AT&T’s LMU information is provided to TWTC as it exists either in AT&T’s databases or in its hard copy facility records. AT&T does not guarantee accuracy or reliability of the LMU information provided, but AT&T shall provide to TWTC the same information that it would provide to itself. 2.21.1.4 AT&T’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either AT&T or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless AT&T receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. Version: 4Q06 Standard ICA 11/30/06 2.21.1.5 TWTC may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular AT&T Loop as long as that equipment does not disrupt other services on the AT&T network. The determination shall be made solely by TWTC and AT&T shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee TWTC’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to AT&T’s network. Except as set forth in Section 2.21.1.6 below, copper-only Loops will not be subject to change due to modification and/or upgrades to AT&T’s network and will remain on copper facilities until the Loop is disconnected by TWTC or the customer, or until AT&T retires the copper facilities via the FCC’s and any applicable Commission’s requirements. TWTC is fully responsible for any of its service configurations that may differ from AT&T’s technical standard for the Loop type ordered.

Appears in 23 contracts

Samples: MFN Agreement, MFN Agreement, Interconnection Agreement

Description of Service. 2.21.1.1 2.16.1.1 AT&T shall make available to TWTC NuVox LMU information with respect to Loops that are required to be unbundled under this Agreement so that TWTC NuVox can make an independent judgment about whether the Loop loop is capable of supporting the advanced services equipment TWTC NuVox intends to install and the services TWTC NuVox wishes to provide. This Section addresses LMU is as a preordering transaction, distinct from TWTC NuVox ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.21.1.2 2.16.1.2 AT&T will provide TWTC NuVox LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair- gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.21.1.3 AT&T’s 2.16.1.3 AT&T‟s LMU information is provided to TWTC NuVox as it exists either in AT&T’s 's databases or in its hard copy facility records. AT&T does not guarantee accuracy or reliability of the LMU information provided, but AT&T shall provide to TWTC NuVox the same information that it would provide to itself. 2.21.1.4 AT&T’s 2.16.1.4 AT&T‟s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either AT&T or the requesting CLEC controlling the Loop(sloop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless AT&T receives the requesting CLEC has a LOA Letter of Authorization (LOA) from the voice CLEC using or controlling the loop (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. Version: 4Q06 Standard ICA 11/30/06 2.21.1.5 TWTC . 2.16.1.5 NuVox may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular AT&T Loop loop as long as that equipment does not disrupt other services on the AT&T network. The determination shall be made solely by TWTC NuVox and AT&T shall not be liable in any way for the performance of the advanced data services provisioned over said Looploop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee TWTC’s NuVox‟s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, the LMU information for Loops other than copper-only Loops if NuVox orders loops that do not require a specific facility medium or loops that are not intended to support advanced services (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to AT&T’s network. Except as set forth in Section 2.21.1.6 below, copper-only Loops will not be subject to change due to modification and/or upgrades to AT&T’s network and will remain on copper facilities until the Loop is disconnected by TWTC or the customer, or until AT&T retires the copper facilities via the FCC’s and any applicable Commission’s requirements. TWTC is fully responsible for any of its service configurations that may differ from AT&T’s technical standard for the Loop type ordered.such

Appears in 3 contracts

Samples: MFN Agreement, MFN Agreement, MFN Agreement

Description of Service. 2.21.1.1 2.9.1.1 AT&T shall make available to TWTC Covad LMU information with respect to Loops that are required to be unbundled under this Agreement so that TWTC Covad can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment TWTC Covad intends to install and the services TWTC Covad wishes to provide. LMU is a preordering transaction, distinct from TWTC Covad ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.21.1.2 2.9.1.2 AT&T will provide TWTC Covad non-discriminatory access to LMU information consisting as it exists in AT&T’s records which may consist of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop Loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair- pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.21.1.3 2.9.1.3 AT&T’s LMU information is provided to TWTC Covad as it exists either in AT&T’s 's databases or in its hard copy facility records. AT&T does not guarantee accuracy or reliability of the LMU information provided, but AT&T shall provide to TWTC the same information that it would provide to itself. 2.21.1.4 2.9.1.4 AT&T’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either AT&T or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless AT&T receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. Version: 4Q06 Standard ICA 11/30/06 2.21.1.5 TWTC . 2.9.1.5 Covad may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular AT&T Loop as long as that equipment does not disrupt other services on the AT&T network. The determination shall be made solely by TWTC Xxxxx and AT&T shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee TWTCCovad’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to AT&T’s network. Except as set forth in Section 2.21.1.6 2.9.1.6 below, copper-only Loops will not be subject to change due to modification and/or upgrades to AT&T’s network and will remain on copper facilities until the Loop is disconnected by TWTC Covad or the customer, or until AT&T retires the copper facilities via the FCC’s and any applicable Commission’s requirementsEnd User. TWTC Covad is fully responsible for any of its service configurations that may differ from AT&T’s technical standard for the Loop type ordered. 2.9.1.6 If AT&T retires its copper facilities in accordance with Section 251(c)(5) of the Act and 47 C.F.R § 51.325 through § 51.335 and any applicable state requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, AT&T will notify Covad, according to the applicable network disclosure requirements. It will be Covad’s responsibility to move any service it may provide over such facilities to alternative facilities. If Covad fails to move the service to alternative facilities by the date in the network disclosure notice, AT&T may terminate the service to complete the network change.

Appears in 2 contracts

Samples: MFN Agreement, MFN Agreement

Description of Service. 2.21.1.1 AT&T 3.11.1.1 BellSouth shall make available to TWTC LMU AT&T loop makeup (LMU) information with respect to Loops that are required to be unbundled under this Agreement so that TWTC AT&T can make an independent judgment about whether the Loop loop is capable of supporting the advanced services equipment TWTC AT&T intends to install and the services TWTC AT&T wishes to provide. This section addresses LMU is as a preordering transaction, distinct from TWTC AT&T ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU loop makeup are likewise unique from other preordering functions with associated SIs service inquiries (SI) as described in this Agreement. 2.21.1.2 AT&T 3.11.1.2 BellSouth will provide TWTC AT&T LMU information consisting of the composition of the Loop loop material (copper/fiber); the existence, location and type of equipment on the Looploop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair- pair-gain devices; the Loop loop length; the wire gauge and electrical parameters. 2.21.1.3 AT&T3.11.1.3 BellSouth’s LMU information is provided to TWTC AT&T as it exists either in AT&T’s BellSouth's databases or in its hard copy facility records. AT&T BellSouth does not guarantee accuracy or reliability of the LMU information provided, but AT&T shall provide to TWTC the same information that it would provide to itself. 2.21.1.4 AT&T’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either 3.11.1.4 AT&T or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless AT&T receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. Version: 4Q06 Standard ICA 11/30/06 2.21.1.5 TWTC may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular AT&T Loop as long as that equipment does not disrupt other services on the AT&T networkBellSouth loop. The determination shall be made solely by TWTC AT&T and AT&T BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Looploop. The specific Loop loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved loop requested taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee TWTCAT&T’s ability to provide advanced data services over the ordered Loop loop type. FurthermoreFurther, if AT&T orders loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible loops) and that are not inventoried as advanced services loops, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, such loops is subject to change at any time due to modifications and/or upgrades to AT&TBellSouth’s network. Except as set forth in Section 2.21.1.6 below, copper-only Loops will not be subject to change due to modification and/or upgrades to AT&T’s network and will remain on copper facilities until the Loop is disconnected by TWTC or the customer, or until AT&T retires the copper facilities via the FCC’s and any applicable Commission’s requirements. TWTC is fully responsible for any of its service configurations that may differ from AT&T’s BellSouth's technical standard for the Loop loop type ordered.

Appears in 1 contract

Samples: Telecommunications

Description of Service. 2.21.1.1 2.9.1.1 AT&T shall make available to TWTC Covad LMU information with respect to Loops that are required to be unbundled under this Agreement so that TWTC Covad can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment TWTC Covad intends to install and the services TWTC Covad wishes to provide. LMU is a preordering transaction, distinct from TWTC Covad ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.21.1.2 2.9.1.2 AT&T will provide TWTC Covad non-discriminatory access to LMU information consisting as it exists in AT&T’s records which may consist of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop Loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair- pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.21.1.3 2.9.1.3 AT&T’s LMU information is provided to TWTC Covad as it exists either in AT&T’s 's databases or in its hard copy facility records. AT&T does not guarantee accuracy or reliability of the LMU information provided, but AT&T shall provide to TWTC the same information that it would provide to itself. 2.21.1.4 2.9.1.4 AT&T’s provisioning of LMU information to the requesting CLEC for facilities is contingent upon either AT&T or the requesting CLEC controlling the Loop(s) that serve the service location for which LMU information has been requested by the CLEC. The requesting CLEC is not authorized to receive LMU information on a facility used or controlled by another CLEC unless AT&T receives a LOA from the voice CLEC (owner) or its authorized agent on the LMUSI submitted by the requesting CLEC. Version: 4Q06 Standard ICA 11/30/06 2.21.1.5 TWTC . 2.9.1.5 Covad may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular AT&T Loop as long as that equipment does not disrupt other services on the AT&T network. The determination shall be made solely by TWTC Covad and AT&T shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee TWTCCovad’s ability to provide advanced data services over the ordered Loop type. Furthermore, the LMU information for Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to AT&T’s network. Except as set forth in Section 2.21.1.6 2.9.1.6 below, copper-only Loops will not be subject to change due to modification and/or upgrades to AT&T’s network and will remain on copper facilities until the Loop is disconnected by TWTC Covad or the customer, or until AT&T retires the copper facilities via the FCC’s and any applicable Commission’s requirementsEnd User. TWTC Covad is fully responsible for any of its service configurations that may differ from AT&T’s technical standard for the Loop type ordered. 2.9.1.6 If AT&T retires its copper facilities in accordance with Section 251(c)(5) of the Act and 47 C.F.R § 51.325 through § 51.335 and any applicable state requirements; or is required by a governmental agency or regulatory body to move or replace copper facilities as a maintenance procedure, AT&T will notify Covad, according to the applicable network disclosure requirements. It will be Covad’s responsibility to move any service it may provide over such facilities to alternative facilities. If Covad fails to move the service to alternative facilities by the date in the network disclosure notice, AT&T may terminate the service to complete the network change.

Appears in 1 contract

Samples: MFN Agreement

Description of Service. 2.21.1.1 AT&T 2.9.1.1 BellSouth shall make available to TWTC AT&T AND TC SYSTEMS LMU information with respect to Loops that are required to be unbundled under this Agreement so that TWTC AT&T AND TC SYSTEMS can make an independent judgment about whether the Loop is capable of supporting the advanced services equipment TWTC AT&T AND TC SYSTEMS intends to install and the services TWTC AT&T AND TC SYSTEMS wishes to provide. This section addresses LMU is as a preordering transaction, distinct from TWTC AT&T AND TC SYSTEMS ordering any other service(s). Loop Makeup Service Inquiries (LMUSI) and mechanized LMU queries for preordering LMU are likewise unique from other preordering functions with associated SIs as described in this Agreement. 2.21.1.2 AT&T 2.9.1.2 BellSouth will provide TWTC AT&T AND TC SYSTEMS LMU information consisting of the composition of the Loop material (copper/fiber); the existence, location and type of equipment on the Loop, including but not limited to digital loop carrier or other remote concentration devices, feeder/distribution interfaces, bridged taps, load coils, pair- pair-gain devices; the Loop length; the wire gauge and electrical parameters. 2.21.1.3 AT&T2.9.1.3 BellSouth’s LMU information is provided to TWTC AT&T AND TC SYSTEMS as it exists either in AT&T’s BellSouth's databases or in its hard copy facility records. AT&T BellSouth does not guarantee accuracy or reliability of the LMU information provided, but AT&T shall provide to TWTC the same information that it would provide to itself. 2.21.1.4 AT&T’s provisioning of 2.9.1.4 BST will provide LMU information to the requesting CLEC for facilities is contingent upon CLEC, if either AT&T BST or the requesting CLEC controlling controls the Loop(s) that serve the service location for which LMU information has been requested by requested. When a CLEC other than the CLEC. The requesting CLEC is that controls the loop requests LMU information, BST will not authorized to receive provide the LMU information on a facility used or controlled by another CLEC unless AT&T BellSouth receives a LOA Letter of Authorization (LOA) from the voice CLEC (owner) or its authorized agent on with the LMUSI submitted by the requesting CLEC. Version: 4Q06 Standard ICA 11/30/06 2.21.1.5 TWTC LMUSI. 2.9.1.5 AT&T AND TC SYSTEMS may choose to use equipment that it deems will enable it to provide a certain type and level of service over a particular AT&T BellSouth Loop as long as that equipment does not disrupt other services on the AT&T BellSouth network. The determination shall be made solely by TWTC AT&T AND TC SYSTEMS and AT&T BellSouth shall not be liable in any way for the performance of the advanced data services provisioned over said Loop. The specific Loop type (e.g., ADSL, HDSL, or otherwise) ordered on the LSR must match the LMU of the Loop reserved taking into consideration any requisite line conditioning. The LMU data is provided for informational purposes only and does not guarantee TWTCAT&T AND TC SYSTEMS’s ability to provide advanced data services over the ordered Loop type. FurthermoreFurther, if AT&T AND TC SYSTEMS orders Loops that do not require a specific facility medium (i.e. copper only) or Loops that are not intended to support advanced services (such as UV-SL1, UV-SL2, or ISDN compatible Loops) and that are not inventoried as advanced services Loops, the LMU information for such Loops other than copper-only Loops (e.g., ADSL, UCL-ND, etc.) that support xDSL services, is subject to change at any time due to modifications and/or upgrades to AT&TBellSouth’s network. Except as set forth in Section 2.21.1.6 below, copper-only Loops will not be subject to change due to modification and/or upgrades to AT&T’s network and will remain on copper facilities until the Loop is disconnected by TWTC or the customer, or until AT&T retires the copper facilities via the FCC’s and any applicable Commission’s requirements. TWTC AND TC SYSTEMS is fully responsible for any of its service configurations that may differ from AT&T’s BellSouth's technical standard for the Loop type ordered.

Appears in 1 contract

Samples: Interconnection Agreement