Droop Response Sample Clauses

Droop Response. (a) AES Hawaii shall perform droop response tests consistent with specifications provided by HECO. These tests will be coordinated around the next scheduled turbine outage (which is currently scheduled for 2018). (b) There is evidence that the DCIS system sees a MW mismatch from the LDC and counters the Facility’s droop response. AES Hawaii shall modify the control logic such that the MW mismatch does not exist during periods of frequency disturbance. AES Hawaii will not commit to replacing the DCIS. Due to the risk of Facility trip when downloading control logic, AES Hawaii will coordinate the timing of the upgrade with HECO to minimize risk. This upgrade will be completed during the next scheduled turbine outage (which is currently scheduled for 2018) while maintaining AES Hawaii safety and reliability standards. (c) AES Hawaii shall perform droop testing to verify the droop curve and verify that the DCIS changes are effective once made. (d) The Facility shall continue to use a droop setting of 5%, with zero deadband.
AutoNDA by SimpleDocs
Droop Response. (a) AES Hawaii will perform droop response tests consistent with specifications provided by Hawaiian Electric. These tests will be coordinated around the next scheduled turbine outage (which is currently scheduled for 2018). Hawaiian Electric to provide testing protocol. (b) There is evidence that the DCIS system sees a MW mismatch from the LDC and counters the Facility’s droop response. AES Hawaii to modify the control logic such that the MW mismatch does not exist during periods of frequency disturbance. AES Hawaii does not commit to replacing the DCIS. Due to the risk of Facility trip when downloading control logic, AES Hawaii will coordinate the timing of the upgrade with Hawaiian Electric to minimize risk. This upgrade will be completed during the next scheduled turbine outage (which is currently scheduled for 2018) while maintaining AES Hawaii’s safety and reliability standards. (c) AES Hawaii will perform droop testing to verify the droop curve and verify that the DCIS changes are effective once made. (d) The Facility will continue to use a droop setting of 5%, with zero deadband.

Related to Droop Response

  • Emergency Response Partners must develop, maintain, and carry out a response plan for public water system emergencies, including disease outbreaks, spills, operational failures, and water system contamination. Partners must notify DWS in a timely manner of emergencies that may affect drinking water supplies.

  • Company’s Response Upon receipt by the Company of a copy of a Conversion Notice, the Company shall as soon as practicable, but in no event later than one (1) Business Day after receipt of such Conversion Notice, send, via email, facsimile or overnight courier, a confirmation of receipt of such Conversion Notice to such Holder indicating that the Company will process such Conversion Notice in accordance with the terms herein. Within two (2) Business Days after the date of the Conversion Confirmation, the Company shall have issued and electronically transferred the shares to the Broker indicated in the Conversion Notice; should the Company be unable to transfer the shares electronically, it shall, within two (2) Business Days after the date of the Conversion Confirmation, have surrendered to FedEx for delivery the next day to the address as specified in the Conversion Notice, a certificate, registered in the name of the Holder, for the number of shares of Common Stock to which the Holder shall be entitled.

  • Agency Response a. OGS will consider all information relevant to the Formal Dispute, and may, in its discretion, suspend, modify, or cancel the disputed procurement/Contract action prior to issuance of a Formal Dispute decision. b. OGS reserves the right to require the filer to meet or participate in a conference call with OGS to discuss the Formal Dispute when, in its sole judgment, circumstances so warrant. c. OGS reserves the right to waive or extend the time requirements for decisions and final determinations on appeals herein prescribed when, in its sole judgment, circumstances so warrant. d. OGS reserves the right to consider or reject the merits of any Formal Dispute.

  • Incident Response Operator shall have a written incident response plan that reflects best practices and is consistent with industry standards and federal and state law for responding to a data breach, breach of security, privacy incident or unauthorized acquisition or use of any portion of Data, including PII, and agrees to provide LEA, upon request, an executive summary of the written incident response plan.

  • Employee Response The employee upon whom a Notice of Proposed Action has been served shall have seven (7) calendar days to respond to the appointing authority either orally or in writing before the proposed action may be taken. Upon request of the employee and for good cause, the appointing authority may extend in writing the period to respond. If the employee's response is not filed within seven (7) days or during an extension, the right to respond is lost.

  • Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.

  • No response Choice of Law

  • Contingent Emergency Response 1. In order to ensure the proper implementation of contingent emergency response activities under Part 4 of the Project (“Contingent Emergency Response Part”), the Recipient shall ensure that: (a) a manual (“CERC Manual”) is prepared and adopted in form and substance acceptable to the Association, which shall set forth detailed implementation arrangements for the Contingent Emergency Response Part, including: (i) any structures or institutional arrangements for coordinating and implementing the Contingent Emergency Response Part;

  • Timing of Company Response The Company shall respond to such claimant within 90 days after receiving the claim. If the Company determines that special circumstances require additional time for processing the claim, the Company can extend the response period by an additional 90 days by notifying the claimant in writing, prior to the end of the initial 90-day period, that an additional period is required. The notice of extension must set forth the special circumstances and the date by which the Company expects to render its decision.

  • Form and Timing of Response (a) Intermediary agrees to provide, promptly upon request of the Fund or its designee, the requested information specified in paragraph 1 above. If requested by the Fund or its designee, Intermediary agrees to use best efforts to determine promptly whether any specific person about whom it has received the identification and transaction information specified in paragraph 1 is itself a financial intermediary (“indirect intermediary”) and, upon further request of the Fund or its designee, promptly either (i) provide (or arrange to have provided) the information set forth in paragraph 1 for those shareholders who hold an account with an indirect intermediary or (ii) restrict or prohibit the indirect intermediary from purchasing, in nominee name on behalf of other persons, securities issued by the Fund. (b) Responses required by this paragraph must be communicated in writing and in a format mutually agreed upon by the parties. (c) To the extent practicable, the format for any transaction information provided to the Fund should be consistent with the NSCC Standardized Data Reporting Format