Entrance Ramp i. The clear space between the gripping surface of the handrails of the ramp and the adjacent surface is 2 inches. Provide handrails where the clear space between the handrails and the adjacent surface is 1 1/2 inches. Standards. §§ 4.1.3(1), 4.3.2(1), 4.8.5, 4.26.1, 4.26.2, Fig. 39(a). ii. The handrails of the ramp do not have ends that are rounded or return smoothly to the floor, wall or post. Provide handrails with ends which are either rounded or returned smoothly to floor, wall, or post . Standards §§ 4.1.3(1), 4.3.2(1), 4.8.5 (3). iii. The top of the handrail gripping surface is 40 inches above the finished surface of the ramp. Provide a handrail on each side of the ramp so that the top of the handrail gripping surface is located between 34 and 38 inches above the ramp surface. Standards §§ 4.1.3(1), 4.3.2(1), 4.8.5(5).
AutoNDA by SimpleDocs
Entrance Ramp. The ramp to the designated accessible entrance is inaccessible because it lacks level landings at the top and bottom of the ramp, and it lacks handrails. Provide a ramp that is at least 36 inches wide with a slope not exceeding 1:12 and a cross slope not exceeding 1:50; with level landings at least as wide as the ramp and 60 inches long at the top and bottom of the ramp; and with edge protection at least 2 inches high at the drop off sides. Provide handrails that are between 1¼ inches and 1½ inches in diameter with a continuous gripping surface along both sides of the ramp, extending at least 12 inches beyond the top and bottom of the ramp parallel with the ground surface. Ensure that handrails are mounted between 34 inches and 38 inches above the ramp surface, with ends rounded or returned smoothly to the floor, wall, or post, and that they do not rotate within their fittings. Ensure that the ramp and approaches are designed so that water will not accumulate on walking surfaces. Standards §§ 4.3.8, 4.8.
Entrance Ramp a. The ramp is inaccessible because handrails are not stable and there are no 12 inch extensions at the top and bottom of the ramp segment. Provide handrails that are between 1 1/4 inches and 1 1/2 inches in diameter such that the inside handrail is continuous and both handrails have a continuous gripping surface along both sides of the ramp extending at least 12 inches beyond the top and bottom of the ramp parallel with the ground surface; the handrails do not rotate within their fittings; and both handrails are mounted between 34 inches and 38 inches above the ramp surface, with ends rounded or returned smoothly to the post. Standards § 4.8.

Related to Entrance Ramp

  • Driveways 2.8 The Shop Response must include the possible impact description as well as a timeframe for restoration of Utility or work area. End users and O&M must be made aware of the possible impact in case of failure of redundant system/equipment. End user(s) and O&M must have some say of the date and time it may take place.

  • Entrance Facilities 7.3.1.1.1 Recurring and nonrecurring rates for Entrance Facilities are specified in Exhibit A and will apply for those DS1 or DS3 facilities dedicated to use by LIS.

  • Entrance Facility The facilities between a Party's designated premises and the Central Office serving that designated premises.

  • LIS Entrance Facilities 7.3.1.1.1 Recurring and nonrecurring rates for LIS Entrance Facilities are specified in Exhibit A and will apply for those DS1 or DS3 facilities dedicated to use as LIS.

  • Parking Throughout the Lease Term, Tenant shall have the exclusive right to use, free of charges, the number of parking spaces set forth in Section 12 of the Summary, which parking spaces constitute the entirety of the parking under the Building and the adjacent surface parking, being all of the parking in the Project. Tenant shall comply with the Parking Rules and Regulations which are in effect on the date hereof, as set forth in the attached Exhibit D and all reasonable modifications and additions thereto which are prescribed from time to time for the orderly operation and use of the Parking Areas by Landlord, and/or Landlord’s Parking Operator (as defined below); provided that such modifications or alterations do not effect Tenant’s use of or access to the Parking Areas. Landlord specifically reserve the right to change the size, configuration, design, layout, of the Parking Areas, and Tenant acknowledges and agrees that Landlord may, without incurring any liability to Tenant and without any abatement of Rent under this Lease, from time to time, temporarily close-off or restrict access to the Parking Areas, so long as Tenant retains access to the number of parking spaces set forth in Section 12 of the Summary. Landlord may delegate its responsibilities hereunder to a parking operator (the “Parking Operator”) in which case the Parking Operator shall have all the rights of control attributed hereby to Landlord. Any parking tax or other charges imposed by governmental authorities in connection with the use of such parking shall be paid directly by Tenant or the parking users, or, if directly imposed against Landlord, Tenant shall reimburse Landlord for all such taxes and/or charges within thirty (30) days after Landlord’s demand therefor. The parking rights provided to Tenant pursuant to this Article 23 are provided solely for use by Tenant’s own personnel visitors and invitees and such rights may not be transferred, assigned, subleased or otherwise alienated by Tenant without Landlord’s prior approval, except in connection with an assignment of this Lease or sublease of the Premises made in accordance with Article 14 above.

  • Sidewalks doorways, vestibules, halls, stairways and other similar areas shall not be obstructed by Tenant or used by Tenant for any purpose other than ingress and egress to and from the Premises. No rubbish, litter, trash, or material shall be placed, emptied, or thrown in those areas. At no time shall Tenant permit Tenant’s employees to loiter in Common Areas or elsewhere about the Building or Property.

  • Basement Any leaks or evidence of moisture? Yes No Unknown Does Not Apply Comments:

  • Roads 16. (1) The Joint Venturers shall —

  • Bathrooms Record the number of bathrooms found on the concerned premises. (7) Common Areas. Furnish the number of common or communal areas available to the Roommates on the premises. (8) Private Areas. Report the number of private rooms or areas found on the premises that the Roommates can access and utilize (alone). III. Term (9)

  • Parking Facilities Alamo Colleges District shall make the existing parking facilities at the rented Facility available for the vehicular traffic and parking necessitated by the Organization’s Use of the rented Facility, on a non-exclusive basis, as specified at Exhibit A. MAXIMUM CAPACITY. Organization anticipates approximately the number of participants stated at Exhibit A and agrees to inform Alamo Colleges District of any significant changes five (5) business days in advance of a Use. Organization shall not admit a larger number of persons than can safely and freely move about the Facility. Alamo Colleges District shall notify Organization of the recommended capacity of the Facility and all decisions of Alamo Colleges District concerning questions arising under this Paragraph shall be final.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!