Common use of INTERCONNECTION AND DELIVERY POINTS, INTERCONNECTION FACILITIES Clause in Contracts

INTERCONNECTION AND DELIVERY POINTS, INTERCONNECTION FACILITIES. Generator 1 - Interconnection Point is at the jaw side of disconnect switch 228. Buyer owns disconnect switch 228 Generator 1 - Delivery Point is the respective connection to the 23kV bus. Interconnection Facilities are the conductors, insulators, support structures, foundations, connectors and hardware between the respective disconnect switch and the 23kV bus. The distance between the Interconnection and Delivery Point is approximately ( ) feet per phase, with a total of approximately ( ) feet of conductor per phase.

Appears in 1 contract

Samples: Asset Sales Agreement (Orion Power Holdings Inc)

AutoNDA by SimpleDocs

INTERCONNECTION AND DELIVERY POINTS, INTERCONNECTION FACILITIES. Generator 1 - Interconnection Point is at the jaw side of disconnect switch 228. 716, Buyer owns disconnect switch 228 716 Generator 1 - Delivery Point is the respective connection to the 23kV 2.4kV bus. Interconnection Facilities are the conductors, insulators, support structures, foundations, connectors and hardware between the respective disconnect switch and the 23kV 2.4kV bus. The distance between the Interconnection and Delivery Point is approximately ( ) feet per phase, with a total of approximately ( ) feet of conductor per phase.

Appears in 1 contract

Samples: Asset Sales Agreement (Orion Power Holdings Inc)

INTERCONNECTION AND DELIVERY POINTS, INTERCONNECTION FACILITIES. Generator 1 & 2 - Interconnection Point is at ax the jaw side of disconnect switch 228. 218, Buyer owns disconnect switch 228 Generator 1 218. Genexxxxx 0 & 0 - Delivery Point is Xxxxxxxx Xxxxx xx the respective connection to the 23kV 46kV bus. Interconnection Facilities are the conductors, insulators, support structures, foundations, connectors and hardware between the respective disconnect switch and the 23kV 46kV bus. The distance between the Interconnection and Delivery Point is approximately ( ) feet per phase, with a total of approximately ( ) feet of conductor per phase.

Appears in 1 contract

Samples: Asset Sales Agreement (Orion Power Holdings Inc)

AutoNDA by SimpleDocs

INTERCONNECTION AND DELIVERY POINTS, INTERCONNECTION FACILITIES. Generator 1 - Interconnection Point is Points are at the jaw side of disconnect switch 228. switches 18 & 28, Buyer owns disconnect switch 228 switches 18 & 28 Generator 1 - Delivery Point is the respective connection to the 23kV 11 5kV bus. Interconnection Facilities are the conductors, insulators, support structures, foundations, connectors and hardware between the respective disconnect switch and the 23kV 115kV bus. The distance between the Interconnection and Delivery Point is approximately ( ) feet per phase, . with a total of approximately ( ) feet of conductor per phase.

Appears in 1 contract

Samples: Asset Sales Agreement (Orion Power Holdings Inc)