MEASURING EQUIPMENT 1. Seller will maintain and operate, atlts own, expense and atthe point of delivery of gas hereunder, a meter or meters and othernecessary equipment by which the volume of gas delivered hereunder shall be measured. Such meters and equipment shall remain the property of the Seller. 2. Buyer agrees lo furnish to Seller electricity for operating Seller's meters, at not cost to Seller. 3. Buyer hereby grants to Seller suitable rlghts-0f-way and easements necessary or Incidental for the installatioo, maintenance, operation and removal of pipeline and other facilities together with rights ofingress thereto and egress there from at all times and hereby agrees to deliver to Seller, for the sum of one dollar ($1.00), an appropriate instrument or grant defining such rights and easements located on Buyer's planlslte. 4. Buyer may install, maintain and operate such check measuring equipment, Including arecording gravltometer and calorimeter as it shall desire, provided that such equipment shall be so installed so as not to Interfere with the operation of Seller's measuring equipment at or near the point of deliver. However, all xxxxxxxx to the Buyer shall be based on the metering of the Seller, subject only to the provisions of Paragraph 8 of this Article. 5. Each party shall have the right to be present at the time of any installing, reading, cleaning, changing, repairing, Inspecting, testing, calibrating, or adjusting done In connection with the other's measuring equlpme!lt used in measuring deliveries hereunder and each party shall advise the other of any Intended major maintenance operation sufficiently in advance in order that the other party may conveniently have its representative present. 6. All installatioo of measuring equipmenL applying to or effecting deliveries hereunder, shall be rnade in such manner as to perrnit an accurate detenninalion of the quantity of gas delivered and ready verification of the accuracy of measurement Orifice meter Installations, If used, shall oonforrn lo the recommendation for design and lnstallatioo contained in the Gas Measurement Commiltee Report No. 3 to the American Gas Association published April, 1955, and any modificatioos and amendments thereof and shall include the use of flange connections. 7. Measurement on Seller's meter or meters shall be conclusive of both parties except where the meter Is defective or fails to register, or if found in E)rror, in either of which case Seller shall repair or replace the meter and the quantity of gas delivered while the meter was out of order or failed to register shall be estimated: (a) By using the registration of any check meter If installed and accurately registering, or, In the absence of (a): (b) By correcting the error If the percentage of error by calibration, test or mathematical calculation, or, in the absence of both (a) and (b) then: (c) By estimating the quantity of delivery from deliveries during periods under similar oonditions when the meter was registering actUrately; and an appropriate billing adjusbnentshall be made In accordance with the current Rules and Regulations governing gas systems issued by the Commission. 8. Seller will maintain its meters in .good order and to this end Wiii make periodic tests of its meters pursuant to the current Rules and Regulations governing gas systems issued by the Commission, or at such shorter intervals as seem to Seller desirable. lfBuyer Is dissatisfied with the accuracy at eny time, it may call upon Seller to have Iha meter tested in accordance with all regulatioos relating to such tests and results of such tesls as found in the current Rules and Regulations governing gas systems issued by the Commission. 9. Each party shall preserve all records for aperiod of at least two (2) years.
Diagnostic procedures to aid the Provider in determining required dental treatment.
Devices BNY Mellon will restrict the transfer of Customer Data from its network to mass storage devices. BNY Mellon will use a mobile device management system or equivalent tool when mobile computing is used to provide the services. Applications on such authenticated devices will be housed within an encrypted container and BNY Mellon will maintain the ability to remote wipe the contents of the container.
Tools (a) The Employer shall provide on all construction jobs, and elsewhere where reasonably necessary and practicable (or if requested by the Employee), a suitable and secure waterproof lock-up solely for the purpose of storing Employees’ tools, and on multi-storey and major projects the Employer shall provide, where possible, a suitable lock-up for Employees’ tools within a reasonable distance of the work area of large groups of Employees. (b) Where an Employee is absent from work because of illness or accident the Employer shall ensure that the Employee’s tools are securely stored during his/her absence.
Year 2000 Compatibility Take all action necessary to assure that its computer based systems are able to operate and effectively process data including dates on and after January 1, 2000, and, at the reasonable request of the Administrative Agent or the Required Lenders, provide evidence to the Lenders of such year 2000 compatibility.
Measuring DNS parameters Every minute, every DNS probe will make an UDP or TCP “DNS test” to each of the public-‐DNS registered “IP addresses” of the name servers of the domain name being monitored. If a “DNS test” result is undefined/unanswered, the tested IP will be considered unavailable from that probe until it is time to make a new test.
Speech Therapy This plan covers speech therapy services when provided by a qualified licensed • loss of speech or communication function; or • impairment as a result of an acute illness or injury, or an acute exacerbation of a chronic disease. Speech therapy services must relate to: • performing basic functional communication; or • assessing or treating swallowing dysfunction. See Autism Services when speech therapy services are rendered as part of the treatment of autism spectrum disorder. The amount you pay and any benefit limit will be the same whether the services are provided for habilitative or rehabilitative purposes.
Secondary Systems The Developer and Connecting Transmission Owner shall each cooperate with the other in the inspection, maintenance, and testing of control or power circuits that operate below 600 volts, AC or DC, including, but not limited to, any hardware, control or protective devices, cables, conductors, electric raceways, secondary equipment panels, transducers, batteries, chargers, and voltage and current transformers that directly affect the operation of Developer or Connecting Transmission Owner’s facilities and equipment which may reasonably be expected to impact the other Party. The Developer and Connecting Transmission Owner shall each provide advance notice to the other Party, and to NYISO, before undertaking any work on such circuits, especially on electrical circuits involving circuit breaker trip and close contacts, current transformers, or potential transformers.
Human Leukocyte Antigen Testing This plan covers human leukocyte antigen testing for A, B, and DR antigens once per member per lifetime to establish a member’s bone marrow transplantation donor suitability in accordance with R.I. General Law §27-20-36. The testing must be performed in a facility that is: • accredited by the American Association of Blood Banks or its successors; and • licensed under the Clinical Laboratory Improvement Act as it may be amended from time to time. At the time of testing, the person being tested must complete and sign an informed consent form that also authorizes the results of the test to be used for participation in the National Marrow Donor program.
Musculoskeletal Injury Prevention and Control The hospital in consultation with the Joint Health and Safety Committee (JHSC) shall develop, establish and put into effect, musculoskeletal prevention and control measures, procedures, practices and training for the health and safety of employees.