MULTI-CARRIER POWER AMPLIFIER REQUIREMENTS Sample Clauses

MULTI-CARRIER POWER AMPLIFIER REQUIREMENTS. The Multi-Carrier Power Amplifier (MCPA) module should be transferable from a Lucent configuration to an Ericsson configuration to a Nortel configuration with no hardware modifications necessary. • The MCPA specified should meet the following specifications: Frequency Range: 869-894 MHz 1930-1990 MHz Instantaneous Bandwidth (minimum) 00 XXx 00 XXx Xxxx Variation: +/- 0.5 dB over DC Input Range Intermodulation Distortion > 65 dBc average (as calculated in IS-136 specifications) over temperature range @ DC input voltage as measured as measured using 24 TDMA carriers over continuous spectrum Gain Adjustable necessary to achieve output power per carrier Operating Temperature 0 to +50C ambient normal operation DC Input Voltage +24 to +28 VDC Input Signal Type AMPS (FM), TDMA (pi/4DQPSK), EDGE (8PSK), WCDMA,1XRTT,HDR,GSM or any combination Output Power Per Carrier Required: Any power per carrier up to composite power available using hybrid combiner capable of supporting minimum 24 carriers Fans (if utilized) Field replaceable by field technician in < 10 minutes Support airflow direction from front to back of system or back to front (forward or reverse) Support notification to system in the event of any of the following occurs: Minor (warning) Fan failure, overdrive input level Major (module shutdown) DC failure, Loop failure, Single module failure failure Critical (subrack shutdown) Over temp shutdown Reverse RF input level exceeds threshold
AutoNDA by SimpleDocs

Related to MULTI-CARRIER POWER AMPLIFIER REQUIREMENTS

  • Functional Requirements Applications must implement controls that protect against known vulnerabilities and threats, including Open Web Application Security Project (OWASP) Top 10 Risks and denial of service (DDOS) attacks.

  • Customer Requirements Customer will be required to maintain complex passwords for their User accounts where applicable. For any such passwords LightEdge will provide a secure URL that any User can access to change passwords. All User passwords are set to a ninety (90) day password expiration schedule by default. LightEdge is not responsible for unexpected use of Services whether by ex-employees, compromised User passwords or any other misuse of Customer accounts. Customer shall be responsible for all costs incurred by such unexpected use of Service. Customer shall be fully responsible for providing to LightEdge at Customer’s own expense and in a timely manner the following: - All security for its Services and systems used or accessible in connection with Service; - Cooperative testing of all Customer-provided hardware, software, and Services for compatibility with Service; - Designating an Authorized Contact(s) to be the point of contact to interface with LightEdge Technical Support; - All cabling necessary to support Service; and - Physical and remote management access to any and all Servers onto which Service is installed.

  • Switching System Hierarchy and Trunking Requirements For purposes of routing ECI traffic to Verizon, the subtending arrangements between Verizon Tandem Switches and Verizon End Office Switches shall be the same as the Tandem/End Office subtending arrangements Verizon maintains for the routing of its own or other carriers’ traffic (i.e., traffic will be routed to the appropriate Verizon Tandem subtended by the terminating End Office serving the Verizon Customer). For purposes of routing Verizon traffic to ECI, the subtending arrangements between ECI Tandem Switches and ECI End Office Switches shall be the same as the Tandem/End Office subtending arrangements that ECI maintains for the routing of its own or other carriers’ traffic.

  • Network Requirements Customer shall be responsible for ensuring that all aspects of the applicable network environment(s) adhere to the applicable standards and requirements specified in the Documentation and are configured appropriately to its proposed use of Ordered SaaS Services.

  • Technical Requirements 4.5.3.1 Tandem Switching shall have the same capabilities or equivalent capabilities as those described in Telcordia TR-TSY-000540 Issue 2R2, Tandem Supplement, June 1, 1990. The requirements for Tandem Switching include but are not limited to the following: 4.5.3.1.1 Tandem Switching shall provide signaling to establish a tandem connection; 4.5.3.1.2 Tandem Switching will provide screening as jointly agreed to by <<customer_short_name>> and BellSouth; 4.5.3.1.3 Where applicable, Tandem Switching shall provide AIN triggers supporting AIN features where such routing is not available from the originating end office switch, to the extent such Tandem switch has such capability; 4.5.3.1.4 Where applicable, Tandem Switching shall provide access to Toll Free number database; 4.5.3.1.5 Tandem Switching shall provide connectivity to Public Safety Answering Point (PSAP)s where 911 solutions are deployed and the tandem is used for 911; and 4.5.3.1.6 Where appropriate, Tandem Switching shall provide connectivity for the purpose of routing transit traffic to and from other carriers. 4.5.3.2 BellSouth may perform testing and fault isolation on the underlying switch that is providing Tandem Switching. Such testing shall be testing routinely performed by BellSouth. The results and reports of the testing shall be made available to <<customer_short_name>>. 4.5.3.3 BellSouth shall control congestion points and network abnormalities. All traffic will be restricted in a non-discriminatory manner. 4.5.3.4 Tandem Switching shall process originating toll free traffic received from <<customer_short_name>>’s local switch. 4.5.3.5 In support of AIN triggers and features, Tandem Switching shall provide SSP capabilities when these capabilities are not available from the Local Switching Network Element to the extent such Tandem Switch has such capability.

  • Unbundled Copper Loops (UCL) 2.4.1 BellSouth shall make available Unbundled Copper Loops (UCLs). The UCL is a copper twisted pair Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters) and is not intended to support any particular telecommunications service. The UCL will be offered in two types – Designed and Non-Designed.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)