Glazing All new and replacement exterior windows shall have sealed, low emmissivity, insulating glass units which are manufactured by members of SIGMA and IGCC. Sealed insulating glass shall meet ASTM E774, class B. Glass shall be hermetically dual sealed, inert gas filled, double pane units with exterior 3/16” bronze float glass (IoE second surface), ½” air space, and interior 3/16” clear float glass. Insulated panels, if used, shall be 1” laminated panels equal to Xxxxx Industries architectural panels with a porcelain fused-on finish. Wired or clear fire-rated glass shall be UL approved. Safety glass shall be tempered or laminated, and shall meet ANSI 297.1 standard.
Toileting the ability to use the lavatory or otherwise manage bowel and bladder functions so as to maintain a satisfactory level of personal hygiene;
Opening an Account Stripe may use information that you provide to Stripe and its Affiliates about a Connected Account to (a) determine the Connected Account’s eligibility to be a Stripe Issuing Accountholder; (b) administer the Stripe Issuing Program; and (c) monitor each Stripe Issuing Accountholder’s Principal Owners, Stripe Issuing Administrators, Card Authorised Users, representatives, and individuals with significant responsibility for management, including executives and senior managers, for the purpose of meeting Stripe’s obligations under Law. Stripe may reject any Connected Account application for, and terminate any Stripe Issuing Accountholder’s access to, the Stripe Issuing Services immediately if any Connected Account, Stripe Issuing Accountholder, Principal Owner, Stripe Issuing Administrator, Card Authorised User, representative, or individual with significant responsibility for management is or becomes a High-Risk Person or uses the Stripe Issuing Program for a Card Unauthorised Purpose.
Cutting, Patching, and Fitting The Contractor shall do all cutting, patching, and fitting of the Work that may be required to make its several parts come together properly and fit.
Cutting and Patching The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make its parts fit together properly.
PAVING Provide a standard bubble map, as part of the plans, showing locations of numbered points, and a table with point number, northing and easting coordinates, description, and BL station for each point, for the following: ▪ all platted control irons (set or not), including plat boundary irons, for the entire sub-division, not just the current phase ▪ benchmarks, including TBM set with preliminary survey In addition to the required coordinate information, the following shall be included in all plans, at a minimum, as needed for construction staking on all City projects. ▪ Include copy of plat(s) on all plans, as relevant and approved by the Design Engineer ▪ Benchmarks – minimum of two City standards, four total desirable; as close to project as possible, even if TBM set with preliminary survey. ▪ Benchmark elevations must be in the same datum as the design (i.e. NAV 88 design needs NAV 88 benchmarks, not NAV 29) ▪ All control irons/identified property irons shall be shown on plans, with BL stationing and offset ▪ Show deflection angles in BL, and/or bearing/azimuth of BL sections ▪ Arterial project side streets – provide BL station at CL of intersection of the two streets, on the BL; BL station and offset to CL of side street at removal limits; include deflection angle from BL to CL of side street ▪ Existing FL/pavement grades shown at all match points ▪ Top of curb grades and stationing at all ends-of-return and horizontal/vertical P.I.’s, not just even stationing ▪ CL top of pavement grades for arterial ▪ CL elevation for streets on mass grading work @ 100’ Sta in tangent sections and 50’ on curves.
Scratches (Q) appliance malfunctions and any resultant leak there from; (R) any stain, soiling or damage resulting from everyday use or which has built up over time, e.g. hair, body or suntan oils and/or lotions; (S) signs of soiling include darkened areas where the body comes into contact with the furniture (these darkened areas are signs of soil build-up, which is not covered); (T) general maintenance and overall cleaning of the furniture is the consumer’s responsibility; (U) damage due to harsh or corrosive chemicals; (V) acids, including without limitation, dyes and inks (except ballpoint), plant food and fertilizer and bleach, gum; (W) any non-operating part or decorative parts such as hinges, knobs, handles, or shelves; (X) coverage under another insurance program; (Y) delivery and/or redelivery and/or loss or damage to the Covered Product while in the course of transit; (Z) design deficiency; (AA) fabrics with “X” cleaning codes and non-colorfast fabrics and leathers; (AB) odors; (AC) variation of the color, or graining of wood or wood products, marble or leather; (AD) split leathers used in seat cushions, back cushions or top or inside arm areas; (AE) natural markings on leather, such as, healed scars, insect bites, brand marks or wrinkles, or suede, and leathers with embossed patterns other than those stimulating natural cowhide; (AF) non- bovine leathers, and other buffed leathers; (AG) stains, color loss or damage resulting from cleaning methods or products (detergents, abrasives or other harsh cleaning agents) other than those recommended by the furniture manufacturer; (AH) stone or sand abrasion; (AI) loss or damage resulting from: pre-existing conditions known to You; (AJ) wear related issues, such as but not limited to, fading, wear, seam separation, stress tears, loss of foam resiliency, pilling or fraying of any fabric on all types of furniture; (AK) color loss or cracking and peeling on any leather or vinyl; (AL) splits or bi-cast leather; (AM) furniture that is used for commercial, institutional, outdoor or rental purposes; (AN) Customer’s Own Material furniture; (AO) wicker, rattan, and teakwood furniture; (AP) massage chairs; (AQ) stains or damage to suede, split-grain leather hide or exotic leathers; (AR) manufacturer quality issues such as stress tears, fabric flaws, fading, color loss or change, loss of foam or resiliency, cracking and peeling of leather or vinyl, natural leather markings, and defects in design and workmanship; (AS) Stains or damage that occur during assembly, delivery, installation, before furniture is delivered to your residence, while the furniture is located outside of your residence, while the furniture is in storage or being moved to or from storage or between residences; (AT) Wear & Tear caused by repeated use such as scuffing, soiling, hair/body oil, perspiration, surface abrasions, pilling or fraying of fabric, loose joints; (AU) Stains or damage covered under any manufacturer warranty, recall, homeowner, renter or other insurance policy; (AV) Stains or damage caused by structural problems, appliance malfunctions, Acts of God or natural disasters, theft, vandalism or illegal activity (AW) Stains or damage caused by independent contractors Specific to Home Automation: In additional to the exclusions listed above, this Agreement does not cover any loss, repairs or damage caused by or resulting from: (A) pre-existing conditions incurred or known to you (pre-existing means a condition prior to Plan issuance); (B) any repair covered by a manufacturer’s warranty or any insurance; (C) installation, or improper installation; or improper installation of customer replaceable components, modules, parts or peripherals; (D) damage or failure due to causes beyond our control such as environmental conditions, exposure to weather conditions or acts of nature including, but not limited to: fire, floods, smoke, sand, dirt, lightning, moisture, water damage, freezes, storms, wind, windstorm, hail, earthquake, animal or insect infestation, etc.; (E) damage or failure caused by riot, nuclear radiation, war, hostile action, or radioactive contamination, etc.; (F) battery failure or leakage; (G) collision, collapse, or explosion; (H) liquid spillage of any kind; (I) signal reception, transmission problems resulting from external causes, interruption of electrical service, loss of power, improper use of electrical/power, power “brown-out”, power overload or power surge (unless covered in the Special Features section of this document); (J) neglect, misuse, abuse, intentional damage, malicious mischief, theft, mysterious disappearance, vandalism or accidental damage; damage cause by dropping (K) rust, corrosion, warping, bending, etc.; (L) damage, warping, bending or rusting of any kind to the housing, cabinetry, outside casing or frame of the product; (M) any non-operating part, including but not limited to plastic, or decorative parts such as hinges, knobs, door liners, glass, handles, masks, rack rollers, shelves, etc.; (N) loss of or repair to components within the product not originally covered by the manufacturer’s warranty; (O) failure to product attachments not provided by the manufacturer or included in the original sale;
Fencing The SPD shall Fence the demarcated boundary of the Demised Premises at the SPD’s own expense in every respect.
Bathrooms Record the number of bathrooms found on the concerned premises. (7) Common Areas. Furnish the number of common or communal areas available to the Roommates on the premises. (8) Private Areas. Report the number of private rooms or areas found on the premises that the Roommates can access and utilize (alone). III. Term (9)
Restrooms The restrooms, toilets, urinals, vanities and the other apparatus shall not be used for any purpose other than that for which they were constructed, and no foreign substance of any kind whatsoever shall be thrown therein. The expense of any breakage, stoppage or damage resulting from the violation of this rule shall be borne by the Tenant whom, or whose employees or invitees, shall have caused it.