Common use of Plumbing and Drainage System Clause in Contracts

Plumbing and Drainage System. All supply pipes, fixtures, and drains shall be installed according to manufacturer recommendations and local codes. All faucets, valves and fixtures shall be of water-saving design. Domestic water systems shall be constructed of type “L” copper with sectionalization and isolation valves installed at branch connections. Storm and sanitary piping shall be service weight cast iron or PVC. Domestic water and interior roof conductors shall be insulated the entire length for temperature control, prevent condensation, and for sound control. Water Supply and Drain Connections: Provide hot and cold water line feeds and drain connections to the kitchenette. Restroom Fixtures: Restroom sinks, toilets and urinals shall be white, commercial grade, vitreous china, and shall be installed in accordance with BFD requirements where applicable. Toilets shall be wall mounted, elongated rims and siphon jet flush action, with top spud for flush valve similar to American Standard “Afwall EL 1.6”. Toilet seats shall be white, heavy duty, solid plastic open at the front, coverless, and shall have stainless steel hinges and built-in bumpers similar to American Standard “Royal” (0039375). Urinals shall be mounted, vitreous china, washout flush action, with top spud for flush valve, similar to American Standard “Washbrook 0.7” (6501.010). Toilets and urinals shall be equipped with flush valve hardware similar to Xxxxx “Royal Flush #110-YB”. Restroom sinks shall be self rimming, white vitreous china measuring 20” long x 17” wide x 8” deep, with 4” faucet centers, similar to American Standard “Aqualyn” (0476.028). Restroom sinks shall be equipped with chrome plated, heavy-duty, commercial grade, single control faucets (without pop-up hole) similar to American Standard “Reliant” (2385.278). Each sink shall be equipped with a polished chrome “Grid Drain” tailpiece for vitreous china similar to American Standard (2411.015) and (7723.018) “Offset Grid Drain” for wheelchair lavatories. ALL sinks shall be handicapped accessible. ALL restrooms and janitor closes shall have floor drains. Break room: Employee break room will be equipped with a stainless steel sink with commercial grade faucet and garbage disposal.

Appears in 22 contracts

Samples: www.michigan.gov, 169.62.82.226, www.michigan.gov

AutoNDA by SimpleDocs

Plumbing and Drainage System. General: All supply pipes, fixtures, and drains shall be installed according to manufacturer recommendations and local codes. All faucets, valves and fixtures shall be of water-saving design. Domestic water systems shall be constructed of type “L” copper with sectionalization and isolation valves installed at branch connections. Storm and sanitary piping shall be service weight cast cost iron or polyvinyl chloride (PVC). Domestic water and interior roof conductors shall be insulated the entire length for temperature control, prevent condensation, and for sound control. Water Supply and Drain Connections: Provide hot and cold water line feeds and drain connections to the kitchenetteNew Public Restroom, Break room, and Large Conference Room. Restroom Fixtures: Restroom sinks, toilets sink and urinals toilet shall be white, commercial grade, vitreous china, and shall be installed in accordance with BFD Barrier Free Design requirements where applicable. Toilets Toilet shall be wall mounted, elongated rims and siphon jet flush action, with top spud for flush valve similar to American Standard “Afwall EL 1.6”. Toilet seats seat shall be white, heavy duty, solid plastic open at the front, front and coverless, and . Seat shall have stainless steel hinges and built-in bumpers similar to American Standard “Royal” (0039375). Urinals shall be mounted, vitreous china, washout flush action, with top spud for flush valve, similar to American Standard “Washbrook 0.7” (6501.010). Toilets and urinals Toilet shall be equipped with flush valve hardware similar to Xxxxx “Royal Flush #110-YB”. Restroom sinks sink shall be self rimming, white vitreous china measuring 20” long x 17” wide x 8” deep, with 4” faucet centers, similar to American Standard “Aqualyn” (0476.028). Restroom sinks sink shall be equipped with chrome plated, heavy-duty, commercial grade, single control faucets (without pop-up hole) similar to American Standard “Reliant” (2385.278). Each sink shall be equipped with a polished chrome “Grid Drain” tailpiece for vitreous china similar to American Standard (2411.015) and (7723.018) “Offset Grid Drain” for wheelchair lavatories. ALL sinks Break room and Conference Room Fixtures, If Applicable: Sinks shall be handicapped accessible. ALL restrooms and janitor closes shall have floor drainsassessable. Break room: Employee break room will sink shall be self rimming, 20 gauge stainless steel with double basins of equal size similar to Xxxx “Sani-Sink” (22114). Overall sink size shall be approximately 24” long x 21” wide x 7.5 “deep. Conference Room sink shall be self-rimming, 20 gauge stainless steel with a single basin similar to Xxxx “Sani-Sink” (22117). Overall sink size shall be approximately 24” long x 21” wide x 7.5” deep. Faucet sets for Break room and Conference Room shall be chrome plated, heavy-duty, commercial grade, single control faucets without spray similar to American Standard “Reliant” (4205.600). Break room sink shall be equipped with a an “In-sink-erator” commercial quality 1/2 hp garbage disposal with sound insulation, lifetime lubricated bearings, and stainless steel sink impellers, grinding chamber and shredder. Electric Water Cooler: Provide an electric water cooler and drinking fountain combination unit located adjacent to the public restroom. Unit shall be "Barrier Free Design", similar to Xxxxxx Xxxxxx Model BCF-7F. Housing and bowl shall be satin finish stainless steel and shall be installed to meet Michigan Barrier Free Law and ADA. Floor Drains and Cleanouts: Provide a floor drain in the public restroom as required by local codes. Floor drains in occupied space shall have nickel bronze finish, heel proof grid top with commercial grade faucet automatic trip primer. Coordinate type of cover with specific floor covering. Floor drains in occupied spaces shall be similar to Xxxx Model Z-415. Floor drains in unoccupied spaces shall be similar to Xxxx Model Z-507-5. Cleanouts for roof conductors and garbage disposaldrain pipe shall have cleanouts installed at changes in direction and along their length as required by local codes and good engineering practice. The cleanouts located in occupied spaces shall have decorative cover or located behind removable covers. Cleanouts and decorative covers shall be similar to Xxxx Model 2-1400.2. Coordinate type of cover with specific wall and floor covering.

Appears in 2 contracts

Samples: www.michigan.gov, www.michigan.gov

AutoNDA by SimpleDocs
Time is Money Join Law Insider Premium to draft better contracts faster.