PROVISION OF RENEWABLE ENERGY Sample Clauses

PROVISION OF RENEWABLE ENERGY. The Competitive Supplier shall procure and provide Renewable Energy Certificates (“RECs”) in a quantity sufficient to support all of the Municipality’s programs described in Exhibit A. The Retail Price set forth in Exhibit A of the ESA includes all costs associated with the provision of Renewable Energy as required under this Agreement.
AutoNDA by SimpleDocs

Related to PROVISION OF RENEWABLE ENERGY

  • Development or Offering of Renewable Energy Sources Competitive Supplier agrees that it will comply with the applicable provisions of X.X.X. x. 00X, § 00X, § 00 F1/2, and any regulations, orders or policies adopted pursuant thereto.

  • Renewable Energy Credits 5.01. Customer shall offer PMPA and/or Utility a first right of refusal before selling or granting to any third party the right to the Green Attributes associated with its customer-owned renewable generation that is interconnected to Utility’s electric distribution system. The term Green Attributes shall include any and all credits, certificates, benefits, environmental attributes, emissions reductions, offsets, and allowances, however entitled, attributable to the generation of electricity from the customer owned-renewable generation and its displacement of conventional energy generation.

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • COVERED HEALTHCARE SERVICES This section describes covered healthcare services. This plan covers services only if they meet all of the following requirements: • Listed as a covered healthcare service in this section. The fact that a provider has prescribed or recommended a service, or that it is the only available treatment for an illness or injury does not mean it is a covered healthcare service under this plan. • Medically necessary, consistent with our medical policies and related guidelines at the time the services are provided. • Not listed in Exclusions Section. • Received while a member is enrolled in the plan. • Consistent with applicable state or federal law. We review medical necessity in accordance with our medical policies and related guidelines. Our medical policies can be found on our website. Our medical policies are written to help administer benefits for the purpose of claims payment. They are made available to you for informational purposes and are subject to change. Medical policies are not meant to be used as a guide for your medical treatment. Your medical treatment remains a decision made by you with your physician. If you have questions about our medical policies, please call Customer Service. When a new service or drug becomes available, when possible, we will review it within six (6) months of one of the events described below to determine whether the new service or drug will be covered: • the assignment of an American Medical Association (AMA) Current Procedural Terminology (CPT) code in the annual CPT publication; • final Food and Drug Administration (FDA) approval; • the assignment of processing codes other than CPT codes or approval by governing or regulatory bodies other than the FDA; • submission to us of a claim meeting the criteria above; and • generally, the first date an FDA approved prescription drug is available in pharmacies (for prescription drug coverage only). During the review period, new services and drugs are not covered. For all covered healthcare services, please see the Summary of Medical Benefits and the Summary of Pharmacy Benefits to determine the amount that you pay and any benefit limits.

  • Electric Storage Resources Developer interconnecting an electric storage resource shall establish an operating range in Appendix C of its LGIA that specifies a minimum state of charge and a maximum state of charge between which the electric storage resource will be required to provide primary frequency response consistent with the conditions set forth in Articles 9.5.5, 9.5.5.1, 9.5.5.2, and 9.5.5.3 of this Agreement. Appendix C shall specify whether the operating range is static or dynamic, and shall consider (1) the expected magnitude of frequency deviations in the interconnection; (2) the expected duration that system frequency will remain outside of the deadband parameter in the interconnection; (3) the expected incidence of frequency deviations outside of the deadband parameter in the interconnection; (4) the physical capabilities of the electric storage resource; (5) operational limitations of the electric storage resources due to manufacturer specification; and (6) any other relevant factors agreed to by the NYISO, Connecting Transmission Owner, and Developer. If the operating range is dynamic, then Appendix C must establish how frequently the operating range will be reevaluated and the factors that may be considered during its reevaluation. Developer’s electric storage resource is required to provide timely and sustained primary frequency response consistent with Article 9.5.5.2 of this Agreement when it is online and dispatched to inject electricity to the New York State Transmission System and/or receive electricity from the New York State Transmission System. This excludes circumstances when the electric storage resource is not dispatched to inject electricity to the New York State Transmission System and/or dispatched to receive electricity from the New York State Transmission System. If Developer’s electric storage resource is charging at the time of a frequency deviation outside of its deadband parameter, it is to increase (for over-frequency deviations) or decrease (for under-frequency deviations) the rate at which it is charging in accordance with its droop parameter. Developer’s electric storage resource is not required to change from charging to discharging, or vice versa, unless the response necessitated by the droop and deadband settings requires it to do so and it is technically capable of making such a transition.

  • Network Resource Interconnection Service (check if selected)

  • Provision of Interconnection Financial Security The Interconnection Customer is obligated to provide all necessary Interconnection Financial Security required under Section 11 of the GIDAP in a manner acceptable under Section 11 of the GIDAP. Failure by the Interconnection Customer to timely satisfy the GIDAP’s requirements for the provision of Interconnection Financial Security shall be deemed a breach of this Agreement and a condition of Default of this Agreement.

  • Use of Verizon Telecommunications Services 2.1 Verizon Telecommunications Services may be purchased by Connectel under this Resale Attachment only for the purpose of resale by Connectel as a Telecommunications Carrier. Verizon Telecommunications Services to be purchased by Connectel for other purposes (including, but not limited to, Connectel’s own use) must be purchased by Connectel pursuant to other applicable Attachments to this Agreement (if any), or separate written agreements, including, but not limited to, applicable Verizon Tariffs.

  • Availability of Verizon Telecommunications Services 3.1 Verizon will provide a Verizon Telecommunications Service to PCS for resale pursuant to this Attachment where and to the same extent, but only where and to the same extent, that such Verizon Telecommunications Service is provided to Verizon’s Customers.

  • Interconnection Agreement On or before December 31, 2015, Wholesale Market Participant must enter into an Interconnection Agreement with the Transmission Owner in order to effectuate the WMPA. Wholesale Market Participant shall demonstrate the occurrence of each of the foregoing milestones to Transmission Provider’s reasonable satisfaction. Transmission Provider may reasonably extend any such milestone dates, in the event of delays that Wholesale Market Participant (i) did not cause and (ii) could not have remedied through the exercise of due diligence. If (i) the Wholesale Market Participant suspends work pursuant to a suspension provision contained in an interconnection and/or construction agreement with the Transmission Owner or (ii) the Transmission Owner extends the date by which Wholesale Market Participant must enter into an interconnection agreement relative to this WMPA, and (iii) the Wholesale Market Participant has not made a wholesale sale under this WMPA, the Wholesale Market Participant may suspend this WMPA by notifying the Transmission Provider and the Transmission Owner in writing that it wishes to suspend this WMPA, with the condition that, notwithstanding such suspension, the Transmission System shall be left in a safe and reliable condition in accordance with Good Utility Practice and Transmission Provider’s safety and reliability criteria. Wholesale Market Participant’s notice of suspension shall include an estimated duration of the suspension period and other information related to the suspension. Pursuant to this section 3.1, Wholesale Market Participant may request one or more suspensions of work under this WMPA for a cumulative period of up to a maximum of three years. If, however, the suspension will result in a Material Modification as defined in Part I, Section 1.18A.02 of the Tariff, then such suspension period shall be no greater than one (1) year. If the Wholesale Market Participant suspends this WMPA pursuant to this Section 3.1 and has not provided written notice that it will exit such suspension on or before the expiration of the suspension period described herein, this WMPA shall be deemed terminated as of the end of such suspension period. The suspension time shall begin on the date the suspension is requested or on the date of the Wholesale Market Participant’s written notice of suspension to Transmission Provider, if no effective date was specified. All milestone dates stated in this Section 3.1 shall be deemed to be extended coextensively with any suspension period permitted pursuant to this provision.

Time is Money Join Law Insider Premium to draft better contracts faster.