Fuel Surcharge NO FUEL SURCHARGES allowed during the term of this contract or any of its extensions. The Successful Contract will not xxxx Xxxxxxx County for any fuel surcharges throughout the term of this contract and its extensions.
Monthly Charges Purchaser shall pay Seller monthly for the electric energy generated by the System and delivered to the Delivery Point at the $/kWh rate shown in Exhibit 1 (the “Contract Price”). The monthly payment for such energy will be equal to the applicable $/kWh rate multiplied by the number of kWh of energy generated during the applicable month, as measured by the System meter.
Interest Charges You agree to pay interest at the rate(s) disclosed to you at the time you open your account and as may be changed from time to time in accordance with applicable law. Average Daily Balance including new transactions: Interest Charges will accrue on your average daily balance outstanding during the month. To get the average daily balance, we take the beginning balance each day, add any new purchases, cash advances, balance transfers or other advances, and subtract any payments, unpaid interest charges, and unpaid late charges. This gives us the daily balance. Then, we add up all the daily balances for the billing cycle and divide that by the number of days in the billing cycle. We then multiply that by the periodic rate corresponding to the Annual Percentage Rate on your account. If you have different rates for purchases, cash advances or balance transfers, separate average daily balances for each will be calculated and the appropriate periodic rate is then applied to each.
Line Outage Costs Notwithstanding anything in the NYISO OATT to the contrary, the Connecting Transmission Owner may propose to recover line outage costs associated with the installation of Connecting Transmission Owner’s Attachment Facilities or System Upgrade Facilities or System Deliverability Upgrades on a case-by-case basis.
Minimum Interest Charge If the interest charge for all balances on your Credit Card account is less than $1.00, we will charge you the Minimum Interest Charge shown on page 1. This charge is in lieu of any interest charge.
Reimbursable Expenses; Maximum Total Payment; Invoicing District will make no payment until this Contract is fully executed by the authorized representatives of both parties.
Electricity Charges The licensee herein shall pay the electricity bills directly for energy consumed on the licensed premises and should submit original receipts to Licensor indicating that the electricity bills are paid.
Minimum Charge The minimum charge against accumulated vacation leave shall be fifteen (15) minutes. Vacation leave shall be compensated at the employee’s base rate of pay, except as otherwise provided in this Agreement.
A-E’S EXPENSE A-E will be responsible for all costs related to photo copying, telephone communications and fax communications while on COUNTY sites during the performance of work and services under this CONTRACT.
CAISO Monthly Billed Fuel Cost [for Geysers Main only] The CAISO Monthly Billed Fuel Cost is given by Equation C2-1. CAISO Monthly Billed Fuel Cost Equation C2-1 = Billable MWh ◆ Steam Price ($/MWh) Where: • Steam Price is $16.34/MWh. • For purposes of Equation C2-1, Billable MWh is all Billable MWh Delivered after cumulative Hourly Metered Total Net Generation during the Contract Year from all Units exceeds the Minimum Annual Generation given by Equation C2-2. Equation C2-2 Minimum Annual Generation = (Annual Average Field Capacity ◆ 8760 hours ◆ 0.4) - (A+B+C) Where: • Annual Average Field Capacity is the arithmetic average of the two Field Capacities in MW for each Contract Year, determined as described below. Field Capacity shall be determined for each six-month period from July 1 through December 31 of the preceding calendar year and January 1 through June 30 of the Contract Year. Field Capacity shall be the average of the five highest amounts of net generation (in MWh) simultaneously achieved by all Units during eight-hour periods within the six-month period. The capacity simultaneously achieved by all Units during each eight-hour period shall be the sum of Hourly Metered Total Net Generation for all Units during such eight-hour period, divided by eight hours. Such eight-hour periods shall not overlap or be counted more than once but may be consecutive. Within 30 days after the end of each six-month period, Owner shall provide CAISO and the Responsible Utility with its determination of Field Capacity, including all information necessary to validate that determination. • A is the amount of Energy that cannot be produced (as defined below) due to the curtailment of a Unit during a test of the Facility, a Unit or the steam field agreed to by CAISO and Owner. • B is the amount of Energy that cannot be produced (as defined below) due to the retirement of a Unit or due to a Unit’s Availability remaining at zero after a period of ten Months during which the Unit’s Availability has been zero. • C is the amount of Energy that cannot be produced (as defined below) because a Force Majeure Event reduces a Unit’s Availability to zero for at least thirty (30) days or because a Force Majeure Event reduces a Unit’s Availability for at least one hundred eighty (180) days to a level below the Unit Availability Limit immediately prior to the Force Majeure Event. • The amount of Energy that cannot be produced is the sum, for each Settlement Period during which the condition applicable to A, B or C above exists, of the difference between the Unit Availability Limit immediately prior to the condition and the Unit Availability Limit during the condition.