Reconfiguration Stage Sample Clauses

Reconfiguration Stage. The ‘Reconfiguration Stage’ comprises the At-Grade Reconfiguration Works in the ‘Car Park 1’, ‘Car Park 3’ and ‘Tennis Courtas shown on the plan attached to Schedule 16 (Plans).
AutoNDA by SimpleDocs

Related to Reconfiguration Stage

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Reformulation Standard “Reformulated Products” shall mean Products that contain concentrations less than or equal to 0.1% (1,000 parts per million (ppm)) of DEHP when analyzed pursuant to U.S. Environmental Protection Agency testing methodologies 3580A and 8270C or other methodology utilized by federal or state government agencies for the purpose of determining the phthalate content in a solid substance.

  • Layout a. Estimate and quantity sheet (1) List of all bid items (2) Bid item quantities (3) Specification item number (4) Paid item description and unit of measure b. Basis of estimate sheet (list of materials) c. General notes and specification data. d. Condition diagram (1) Highway and intersection design features (2) Roadside development (3) Traffic control including illumination e. Plan sheet(s) (1) Existing traffic control that will remain (signs and markings) (2) Existing utilities (3) Proposed highway improvements (4) Proposed installation (5) Proposed additional traffic controls (6) Proposed illumination attached to signal poles. (7) Proposed power pole source f. Notes for plan layout g. Phase sequence diagram(s) (1) Signal locations (2) Signal indications (3) Phase diagram (4) Signal sequence table (5) Flashing operation (normal and emergency) (6) Preemption operation (when applicable) (7) Contact responsible Agency to obtain interval timing, cycle length and offset h. Construction detail sheets(s) (1) Poles (State standard sheets) (2) Detectors (3) Pull Box and conduit layout (4) Controller Foundation standard sheet (5) Electrical chart i. Marking details (when applicable)

  • Recommended language skills The sending institution, following agreement with the receiving institution, is responsible for providing support to its nominated candidates so that they can have the recommended language skills at the start of the study or teaching period:

  • Construction Standards The Developer shall construct the Subdivision in accordance with the Subdivision Plan, as approved by the Planning Commission, and if applicable, the requirements of the Design Review Committee, and in accordance with the requirements of (a) the Millington Subdivision Regulations; (b) standards and specifications contained in “Local Public Works Standard, and Specifications”, as amended to include specific requirements for construction in Millington, TN; (c) the Building Code (as adopted by Shelby County); (d) the Fire Code (as adopted by Shelby County); (e) the Millington Zoning Ordinance; and (f) the applicable Ordinances of the City. Items (a) through (f) are hereby made a part of this Agreement by reference and are hereinafter referred to collectively as the “Codes”. References herein to the Codes are to those in effect on the Effective Date unless amendments are hereafter made which apply to all improvements or subdivisions regardless of their date of commencement and/or completion of construction. The Conditions of Approval established by the Planning Commission, and, as applicable, the Design Review Committee (any or all of which as may have been modified by the Board of Mayor and Aldermen) are set forth in Exhibit “A” to this Agreement and are incorporated herein by reference and made a part hereof.

  • Mission Statement a. Employees are the most valuable resource in the City’s effective and efficient delivery of services to the public. The parties have a commitment to prevent drug or alcohol impairment in the workplace and to xxxxxx and maintain a drug and alcohol free work environment. The parties also have a mutual interest in preventing accidents and injuries on the job and, by doing so, protecting the health and safety of employees, co-workers, and the public. b. In agreeing to implement this Substance Abuse Prevention Policy (XXXX), the parties affirm their belief that substance abuse is a treatable condition. The City is committed to identifying needed resources, both in and outside of the City, for employees who voluntarily seek assistance in getting well. Those employees who voluntarily seek treatment prior to any testing shall not be subject to any repercussions or any potential adverse action for doing so. However, seeking treatment will not excuse prior conduct for which an investigation or disciplinary proceedings have been initiated. c. The City is committed to preventing drug or alcohol impairment in the workplace, and to fostering and maintaining a safe work environment free from alcohol and prohibited drugs at all of its work sites and facilities. In addition, the City maintains a drug and alcohol free workplace policy in its Employee Handbook.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Reformulation Standards A “reformulated” product (a) contains lead in concentrations that do not exceed 90 parts per million, equivalent to 0.009%, in any exterior parts analyzed pursuant to U.S. Environmental Protection Agency (EPA) methodologies 3050B and 6010B, or (b) yields a result of no more than 1.0 micrograms of lead when sampled according to NIOSH 9100 protocol and analyzed according to EPA 6010B. In addition to the above tests, the Settling Entity may use equivalent methods utilized by any California or federal agency to determine lead content in a solid substance or the amount of the bioavailability of the toxicant through a wipe test, respectively.

  • Power System Stabilizers The Developer shall procure, install, maintain and operate Power System Stabilizers in accordance with the requirements identified in the Interconnection Studies conducted for Developer’s Large Generating Facility. NYISO and Connecting Transmission Owner reserve the right to reasonably establish minimum acceptable settings for any installed Power System Stabilizers, subject to the design and operating limitations of the Large Generating Facility. If the Large Generating Facility’s Power System Stabilizers are removed from service or not capable of automatic operation, the Developer shall immediately notify the Connecting Transmission Owner and NYISO. The requirements of this paragraph shall not apply to wind generators.

  • Space Plan Tenant or Tenant’s Architect shall prepare a proposed space plan for the Tenant Improvements in the Premises which shall include a layout and designation of all partitioning, intended use for such space and equipment to be contained therein (the “Space Plan”) and shall deliver the proposed Space Plan to Landlord with a request for Landlord’s approval. Landlord shall approve or disapprove the Space Plan by written notice given to Tenant within ten (10) Business Days after receipt of the Space Plan. Landlord shall not unreasonably withhold its approval of the Space Plan, provided that, without limiting the generality of the foregoing, Landlord shall be entitled to withhold its consent to the Space Plan if, in Landlord’s good faith judgment, any one or more of the following conditions exist: (a) the proposed Tenant Improvements will adversely affect the exterior appearance of the Building; (b) the proposed Tenant Improvements may impair the structural strength of the Building, affect any of the Base Building Systems or adversely affect the value of the Building; or (c) the proposed Tenant Improvement Work would trigger the necessity under Applicable Laws or otherwise for work to be performed outside the Premises. If Tenant’s proposed interior partitioning or other aspects of the Tenant Improvement Work will, in Landlord’s good faith judgment, require changes or alterations in the Base Building Systems located outside of the Premises, and Landlord approves such changes or alterations, such changes or alterations shall be made at Tenant’s expense. If Landlord disapproves the Space Plan, Landlord shall return the Space Plan to Tenant with a statement of Landlord’s reasons for disapproval, or specifying any required corrections and/or revisions. Landlord shall approve or disapprove of any revisions to the Space Plan by written notice given to Tenant within five (5) Business Days after receipt of such revisions. This procedure shall be repeated until Landlord approves the Space Plan (as so approved, the “Approved Space Plan”).

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!