Relevant Design Features. The relevant design features of the VanishPoint syringe that are inspected are as follows: ---------------------------------------------------------------------------------------------------------- Class I Defects Class II Defects Class III Defects Class IV Defects Class V Defects ---------------------------------------------------------------------------------------------------------- None Correct Plunger Cap Needle Holder Lubricant in Barrel None [Yellow] (Interface Diameter [.0030g - .0065g] .036" - .038") ---------------------------------------------------------------------------------------------------------- Correct Barrel Print Needle Holder Alignment Pushout [Minimum 2.0 lbs] ---------------------------------------------------------------------------------------------------------- Activation Force [Maximum 12.5 lbs] ----------------------------------------------------------------------------------------------------------
Appears in 1 contract
Samples: Contract Manufacturing Agreement (Retractable Technologies Inc)
Relevant Design Features. The relevant design features of the VanishPoint syringe that are inspected are as follows: ---------------------------------------------------------------------------------------------------------- Class I Defects Class II Defects Class III Defects Class IV Defects Class V Defects ---------------------------------------------------------------------------------------------------------- None Correct Plunger Cap Needle Holder Lubricant in Barrel None [YellowGreen] (Interface Diameter [.0030g - .0065g] .036.033" - .038.035") ---------------------------------------------------------------------------------------------------------- Correct Barrel Print Needle Holder Alignment Pushout [Minimum 2.0 lbs] ---------------------------------------------------------------------------------------------------------- Activation Force [Maximum 12.5 lbs] ----------------------------------------------------------------------------------------------------------
Appears in 1 contract
Samples: Contract Manufacturing Agreement (Retractable Technologies Inc)
Relevant Design Features. The relevant design features of the VanishPoint syringe that are inspected are as follows: ---------------------------------------------------------------------------------------------------------- Class I Defects Class II Defects Class III Defects Class IV Defects Class V Defects ---------------------------------------------------------------------------------------------------------- None Correct Plunger Cap Needle Holder Lubricant in Barrel None [YellowBlack] (Interface Diameter [.0030g - .0065g] .036.029" - .038.031") ---------------------------------------------------------------------------------------------------------- Correct Barrel Print Needle Holder Alignment Pushout [Minimum 2.0 lbs] ---------------------------------------------------------------------------------------------------------- Activation Force [Maximum 12.5 lbs] ----------------------------------------------------------------------------------------------------------
Appears in 1 contract
Samples: Contract Manufacturing Agreement (Retractable Technologies Inc)
Relevant Design Features. The relevant design features of the VanishPoint syringe that are inspected are as follows: ---------------------------------------------------------------------------------------------------------- Class I Defects Class II Defects Class III Defects Class IV Defects Class V Defects ---------------------------------------------------------------------------------------------------------- None Correct Plunger Cap Needle Holder Lubricant in Barrel None [Yellow] (Interface Diameter [.0030.0060g - .0065.0100g] .036" - .038") ---------------------------------------------------------------------------------------------------------- Correct Barrel Print Needle Holder Alignment Pushout [Minimum 2.0 lbs] ---------------------------------------------------------------------------------------------------------- Activation Force [Maximum 12.5 12.0 lbs] ----------------------------------------------------------------------------------------------------------
Appears in 1 contract
Samples: Contract Manufacturing Agreement (Retractable Technologies Inc)
Relevant Design Features. The relevant design features of the VanishPoint syringe that are inspected are as follows: ---------------------------------------------------------------------------------------------------------- Class I Defects Class II Defects Class III Defects Class IV Defects Class V Defects ---------------------------------------------------------------------------------------------------------- None Correct Plunger Cap Needle Holder Lubricant in Barrel None [YellowGreen] (Interface Diameter [.0030.0060g - .0065.0100g] .036" - .038") ---------------------------------------------------------------------------------------------------------- Correct Barrel Print Needle Holder Alignment Pushout [Minimum 2.0 lbs] ---------------------------------------------------------------------------------------------------------- Activation Force [Maximum 12.5 12.0 lbs] ----------------------------------------------------------------------------------------------------------
Appears in 1 contract
Samples: Contract Manufacturing Agreement (Retractable Technologies Inc)
Relevant Design Features. The relevant design features of the VanishPoint syringe that are inspected are as follows: ---------------------------------------------------------------------------------------------------------- Class I Defects Class II Defects Class III Defects Class IV Defects Class V Defects ---------------------------------------------------------------------------------------------------------- None Correct Plunger Cap Needle Holder Lubricant in Barrel None [YellowBlack] (Interface Diameter [.0030.0060g - .0065.0100g] .036.029" - .038.031") ---------------------------------------------------------------------------------------------------------- Correct Barrel Print Needle Holder Alignment Pushout [Minimum 2.0 lbs] ---------------------------------------------------------------------------------------------------------- Activation Force [Maximum 12.5 12.0 lbs] ----------------------------------------------------------------------------------------------------------
Appears in 1 contract
Samples: Contract Manufacturing Agreement (Retractable Technologies Inc)