Retain Special Inspection Records. The contractor is also responsible for retaining at the jobsite all special inspection records submitted by the special inspector, and providing these records for review by the Building Division's inspector upon request.
AutoNDA by SimpleDocs
Retain Special Inspection Records. The contractor shall retain at the jobsite all special inspection records submitted by the SI and make these records available for review by Owner, EAR, BO or BO’s Representative upon request. Permit # Project Address: STRUCTURAL TESTS AND INSPECTIONS SCHEDULE Designate required Special Inspections and Testing Below. Xxxx required inspections with C to denote CONTINUOUS Inspection P to denote PERIODIC Inspection STRUCTURAL STEEL: INSULATING CONCRETE: UNDERPINNING: Sample & Test (list specific numbers below) Sample & Test Inspection of Steel Fabrication Shop Ident. & Welding Inspection Unit Weights Inspecting of Reinforcing Forms Shop Ultrasonic Inspection Inspection of Concrete Placement Shop Radiography FIREPROOFING: Inspection of Tiebacks Field Welding Inspection Inspection of Placemet Field Bolting Inspection Density Tests Field Ultrasonic Inspection Thickness Tests MASONRY: Field Radiology Inspect Batching Preliminary Acceptance Tests Metal Deck Welding Inspection (Masonry Units, Wall Prisms) Subsequent Tests (Mortar, Grout, FILL MATERIAL: Field Wall Prisms) REINFORCING STEEL: Acceptance Tests Inspection of Grouting Tensile & Bend, one set per heat per Moisture Density Determination Inspection of Placement & Grouting tons Field Density Inspection of Placement Inspection of Welding ROOFING: ASPHALTIC CONCRETE: Inspection Mix Designs Sample & Test Inspection of Batch Plant PRECAST/CONCRETE: Core/Test STRUCTURAL WOOD: Field Inspection Reinforcing Tests Inspection of Fabrication Suitability Tests Inspection of Reinforcing Placement Inspection of Truss Joist Fab Specific Gravity Tendon Tests Sample & Test Components Asphalt Content Inspection of Tendon Placement Inspection of Glu-xxx Fab Sieve Analysis Inspection of Concrete Placement K Factors Inspection of Concrete Batching PILING, CAISSONS, CAPS, TIES: Stabilometer Value Inspection of Panel Attach & Inserts Inspection of Reinforcing Placement Swell Inspection of Panel Installation Inspection of Concrete Placement Compression of Tests OTHER: Inspection of Stressing/Transfer Other Tests, Inspections or Special Instructions Conc Grout Mortar Suitability of Agg. Mix Designs Test Panel Batch Plant Insp. Cement Grab Sample Inspect Placing Compression Tests Cast Specimens Pick-up Samples Shrinkage Bars Yield Check Air Check Dry Unit Weight Concrete: Footing fc = Slab fc = Piers fc = Lt. Weight fc = Columns fc = Susp. Slab fc = Grout: PSI = Mortar: PSI = NOTE: A concrete strength test shall be the average of two...
Retain Special Inspection Records. The contractor shall retain at the jobsite all special inspection records submitted by the SI and make these records available for review by Owner, EAR, BO or XX’s Representative upon request. BSD-138 Form - Special Inspection and Testing Agreement Updated: 3/3/17 (jhall) Permit # Project Address STRUCTURAL TESTS AND INSPECTIONS SCHEDULE Designate required Special Inspections and Testing Below. Mark required inspections with C to denote CONTINUOUS Inspection P to denote PERIODIC Inspection STRUCTURAL STEEL: INSULATING CONCRETE: UNDERPINNING: Sample & Test (list specific numbers Sample & Test Inspection of Steel Fabrication
Retain Special Inspection Records. The contractor is also responsible for retaining at the jobsite all special inspection records submitted by the special inspector, and providing these records for review by the Building Department's inspector upon request. SPECIAL INSPECTION AND TESTING AGENCIES RECOGNIZED BY THE CITY OF MONTEREY: Updated: June 1, 2020 KEY: SPECIAL INSPECTION & Testing Agencies Recognized by City of Monterey Building and Safety Division RC = Reinforced Concrete PC = Prestressed Concrete SM = Structural Masonry FP = Fireproofing HSB = High Strength Bolting NDT = Non-destructive Testing SWC = Structural Wood Construction SW = Steel Welding Agency Name Address Phone/Fax RC PC SM SW HSB SWC URM FP NDT Expiration Achievement Engineering Corp – AEC 0000 Xxxxxxxxxx Xx., Xxxx X Xxx Xxxx, XX 00000 (408) 217-9174 (000) 000-0000 X X X X X X X X X 3/6/2022 Advanced Testing & Inspection (ATI) 000 Xxxxxxx Xxxxxx, Suite B Salinas, CA 93901 (831) 422-2272 (000) 000-0000 X X X X X X X 10/1/2022 Xxxxxxxx Xxxxxxx and Associates 0000 Xxxxx Xxxxxxxxx Xxxxxxxxxx, XX 00000 (925) 484-0220 (000) 000-0000 X X X X X X X 9/4/2021 Xxxxx Xxxxxxx Associates, Inc.* 000 Xxx Xxxxxxx, Xxx Xxxx, XX 00000 (408) 296-5515 (000) 000-0000 X X X X X X 11/7/2020 B.S.K. Associates 000 Xxxxxxxxx Xxx Xxxxxxxxx, XX 00000 (925) 315-3151 (000) 000-0000 X X X X X X X X 2/14/2021 Consolidated Engineering Labs 0000 Xxxx Xxxxxx Xx, Xxxxx 000 Xxx Xxxxx, XX 00000 (925) 314-7100 (000) 000-0000 X X X X X X X X X 10/18/2021 Earth System Pacific** 00000 Xxxx Xxxxxxx Xxxx,Xxx 000 Xxxxxxx, XX 00000 (510) 353-3833 (000) 000-0000 X X X X X X X X 10/25/2020 ENGEO Incorporated 0000 Xxxx Xxxxxx Xx., Xxxxx 000 Xxx Xxxxx, XX 00000 (925) 866-9000 (000) 000-0000 X X X X X X X X X 8/7/2022 HP Inspections 000 Xxxxx Xxxxxx, Xxxx. H San Jose, CA 00000 (000) 000-0000 (000) 000-0000 X X X X X X X X 1/8/2021 Inspection Services Inc. 0000 Xxxxxxxxxx Xxxxxx Xxxxxxxx, XX 00000 (510) 900-2100 (000) 000-0000 X X X X X X X X X 6/25/2022 KC Engineering Co. 000 Xxxxxxx Xxxx, Xxxxx X Xxxxxxxxx, XX 00000 (707) 447-4025 (000) 000-0000 X X X X X X X 11/7/2020 Xxxxxxxxxxx Inc. 0000 Xxxxxxxxxx Xx. Hayward, CA 00000 (000) 000-0000 (000) 000-0000 X X X X X X X X 7/30/2022 Korbmacher Engineering, Inc. 000 Xxxxxxx Xxxxx, Xxxxx X Xxxxxxxxx, XX 00000 (925) 454-9033 (000) 000-0000 X X X X X X X X 4/11/2020 Krazan and Associates Inc. 0000 Xxxxxxxxxx Xxxx Xxxxx X. Xxxxxxxxxx, XX 00000 (925) 307-1160 (000) 000-0000 X X X X X X X X X 1/5/2021 MatriScope Engineering Laborat...
Retain Special Inspection Records. The contractor is also responsible for retaining at the job site all special inspection records submitted by the special inspector, and providing these records for review of the City of Las Vegas (or Xxxxx County) Building Department’s inspector upon request.

Related to Retain Special Inspection Records

  • Contractor’s Records The Contractor shall keep true and accurate accounts, records, books and data which shall correctly reflect the business transacted by the Contractor in accordance with generally accepted accounting principles. These records shall be stored in Orange County for a period of three (3) years after final payment is received from the County. Storage of records in another county will require written approval from the County of Orange assigned Deputy Purchasing Agent.

  • Right to Inspect Records Engineer agrees that City shall have access to and the right to examine any directly pertinent books, documents, papers and records of Engineer involving transactions relating to this contract. Engineer agrees that City shall have access during normal working hours to all necessary Engineer facilities and shall be provided adequate and appropriate work space in order to conduct audits in compliance with the provisions of this section. City shall give Engineer reasonable advance notice of intended audits. Engineer further agrees to include in subcontract(s), if any, a provision that any subcontractor or consultant agrees that City shall have access to and the right to examine any directly pertinent books, documents, papers and records of such consultant or subcontractor involving transactions to the subcontract, and further, that City shall have access during normal working hours to all consultant or subcontractor facilities, and shall be provided adequate and appropriate work space, in order to conduct audits in compliance with the provisions of this paragraph. City shall give the consultant or subcontractor reasonable advance notice of intended audits.