Common use of Revenue Metering Clause in Contracts

Revenue Metering. The Connecting Transmission Owner revenue metering shall be located at the Fairway Solar Collector Substation on the generator side of the 115kV breaker in accordance with the requirements identified in the Project Specific Specifications (as defined below), and shall consist of: • three (3) combination current/voltage transformer (“CT/VT”) units (manufacturer and model shall be ABB/Hitachi KXM-550 or other Connecting Transmission Owner specified equivalent); and • one (1) revenue meter. The ratios of the CTs and VTs will be provided upon review of the Interconnection Customer’s design documents according to Connecting Transmission Owner’s Electric System Bulletin (“ESB”) 752. (Note: The Connecting Transmission Owner’s revenue metering CTs and VTs cannot be used to feed the Interconnection Customer’s check meter.) The metering of any redundant or standby station service provisions at the Fairway Solar Collector Station shall be added in accordance with the Connecting Transmission Owner’s retail tariff, PSC No. 220 and the Connecting Transmission Owner’s ESB 750.

Appears in 4 contracts

Samples: Service Agreement, Service Agreement, Service Agreement

AutoNDA by SimpleDocs

Revenue Metering. The Connecting Transmission Owner revenue metering shall be located at in the Fairway Hawthorn Solar Collector Substation control enclosure on the generator side of the 115kV breaker in accordance with the requirements identified in the Project Specific Specifications (as defined below), and shall consist of: • three (3) combination current/voltage potential transformer (CT/VT”PT) units (manufacturer units, also called metering units, one for each phase. Manufacturer and model shall be ABB/Hitachi KXM-550 or other Connecting Transmission Owner specified specific equivalent); • revenue meter; and • one (1) revenue metersocket. The ratios of the CTs and VTs PTs will be provided by the Connecting Transmission Owner upon review of the Interconnection Customer’s design documents according to Connecting Transmission Owner’s Electric System Bulletin (“ESB”) 752in accordance with the ESBs. (Note: The Connecting Transmission Owner’s revenue metering CTs and VTs PTs cannot be used to feed the Interconnection Customer’s check meter.) ). The metering of any redundant or standby station service provisions (if required) at the Fairway Hawthorn Solar Collector Station Substation shall be added in accordance with the Connecting Transmission Owner’s retail tariff, PSC No. 220 220, and the Connecting Transmission Owner’s ESB 750.

Appears in 2 contracts

Samples: Service Agreement, Service Agreement

AutoNDA by SimpleDocs

Revenue Metering. The Connecting Transmission Owner owned revenue metering shall be located at the Fairway Hilltop Solar Collector Substation Station on the generator side of the 115kV breaker in accordance with the requirements identified in the Project Specific Specifications (as defined below), and shall consist of: • three (3) combination current/voltage transformer (“CT/VT”) units (manufacturer and model shall be ABB/Hitachi KXM-550 Xxxxxxx KXM-550, GE Grid Solutions KOTEF 000.XX, or other Connecting Transmission Owner specified equivalent); and • one (1) revenue meter. The ratios of the CTs and VTs will be provided upon review of the Interconnection Customer’s design documents according to Connecting Transmission Owner’s Electric System Bulletin (“ESB”) 752. (Note: The Connecting Transmission Owner’s revenue metering CTs and VTs cannot be used to feed the Interconnection Customer’s check meter.) The metering of any redundant or standby station service provisions at the Fairway Hilltop Solar Collector Station shall be added in accordance with the Connecting Transmission Owner’s retail tariff, PSC No. 220 and the Connecting Transmission Owner’s ESB 750.

Appears in 1 contract

Samples: Service Agreement