Secondary Devices Sample Clauses

Secondary Devices. Secondary devices utilized for the mass measurement shall be as follows and be of sufficient quality to provide overall flow measurement uncertainty of one percent maximum. 1) Differential pressure measurement devices used with orifice measurements shall have vendor's specified inaccuracy of a maximum of +0.25 percent of - calibrated span with +0.10 percent being preferred. The ambient temperature - effect on the differential pressure device shall not exceed 1.0 percent of total combined span and zero effect per 100 F. If a 0.25% D/P transmitter is used, a heated housing (3.3.8) is required. If 0.1% D/P transmitter is used (i.e., "smart" transmitter) no heated enclosure is required. Differential pressure devices shall be compensated by online computation for any vendor specified static pressure effect (as with capacitance type detector). No single differential pressure device shall be utilized over a differential rangeability in excess of 4:1 (i.e. 100" to 25"). Two parallel devices should be utilized for a rangeability up to 16:1, however, if absolutely necessary, a third differential device could be utilized to provide differential rangeability to 64:1 (flow rangeability of 8:1). Expanded rangeabilities require sound engineering judgement and require mutual consent of the Parties. Very low flow rates at very low differentials could not be expected to provide a one percent or less flow measurement uncertainly. Differential pressure measurement devices shall not be utilized with calibration of less than one-half of its maximum span rating. EXHIBIT B --------- MEASUREMENT AND SAMPLING XXXXX PROPANE SALES OCTOBER 1, 1999 PAGE 7 -------------------------------------------------------------------------------- The meter run and orifice shall be properly sized and the facility operated in such a manner that the normal long duration flow rates operates above 50 percent (preferably about 75 percent) of the calibrated range of the primary differential device. 2) Static Pressure Transmitters ------------------------------ The pressure device specifications should be equal to the differential pressure device given above. The general specification should be at least +0.25 percent - of span accuracy with a stability effect of +0.25 percent over a six-month - period and an ambient temperature effect equal to or better than 1.0 percent of total combined span and zero effect per 100 F. The static pressure device for an orifice meter shall be connected to the downstream or...
AutoNDA by SimpleDocs

Related to Secondary Devices

  • Safety Devices All Products provided under the Contract shall be equipped with required safety devices to comply with all applicable codes, laws, and regulations that are in effect at the time of delivery.

  • Security Devices Either party may record any of their telephonic communications. Customer shall comply with any security procedures reasonably required by Bank from time to time with respect to verification of Instructions. Customer shall be responsible for safeguarding any test keys, identification codes or other security devices that Bank shall make available to Customer or any Authorized Person.

  • Secondary Systems The Developer and Connecting Transmission Owner shall each cooperate with the other in the inspection, maintenance, and testing of control or power circuits that operate below 600 volts, AC or DC, including, but not limited to, any hardware, control or protective devices, cables, conductors, electric raceways, secondary equipment panels, transducers, batteries, chargers, and voltage and current transformers that directly affect the operation of Developer or Connecting Transmission Owner’s facilities and equipment which may reasonably be expected to impact the other Party. The Developer and Connecting Transmission Owner shall each provide advance notice to the other Party, and to NYISO, before undertaking any work on such circuits, especially on electrical circuits involving circuit breaker trip and close contacts, current transformers, or potential transformers.

  • Network Interface Device 4.1 The NID is defined as any means of interconnection of end-user customer premises wiring to BellSouth’s distribution plant, such as a cross-connect device used for that purpose. The NID is a single-line termination device or that portion of a multiple-line termination device required to terminate a single line or circuit at the premises. The NID features two independent xxxxxxxx or divisions that separate the service provider’s network from the End User’s on-premises wiring. Each chamber or division contains the appropriate connection points or posts to which the service provider and the End User each make their connections. The NID provides a protective ground connection and is capable of terminating cables such as twisted pair cable. 4.1.1 BellSouth shall permit Al-Call to connect Al-Call ’s loop facilities to on-premises wiring through the BellSouth NID or at any other technically feasible point.

  • Computer Equipment Recycling Program If this Contract is for the purchase or lease of computer equipment, then Contractor certifies that it is in compliance with Subchapter Y, Chapter 361 of the Texas Health and Safety Code related to the Computer Equipment Recycling Program and the Texas Commission on Environmental Quality rules in 30 TAC Chapter 328.

  • Secondary Schools In the middle and high schools, areas of certification shall be deemed to 21 be the areas for which the employee holds certification. No teacher assignment that would result 22 in a violation of state or federal law will be approved.

  • Diagnostic procedures to aid the Provider in determining required dental treatment.

  • OPEN SOURCE COMPONENTS The DS Offerings may include open source components. Whenever notices (such as acknowledgment, copies of licenses or attribution notice) are required by the original licensor, such notices are included in the Documentation of the DS Offerings. Moreover, some open source components may not be distributed and licensed under the terms of the Agreement but under the terms of their original licenses as set forth in the Documentation of the DS Offerings themselves. Source code for open source software components is available upon request. Except for components mentioned in the section EXCLUSIONS below, the warranty and indemnification provided by DS under the Agreement apply to all open source software components and shall be provided by DS and not by the original licensor, but only for the use of the DS Offerings that is in compliance with the terms of the Agreement, and in conjunction with the DS Offerings. The original licensors of said open source software components provide them on an “as is” basis and without any liability whatsoever to Customer.

  • Television Equipment Recycling Program If this Contract is for the purchase or lease of covered television equipment, then Contractor certifies that it is compliance with Subchapter Z, Chapter 361 of the Texas Health and Safety Code related to the Television Equipment Recycling Program.

  • Apple and Android Devices The following terms apply when you use a mobile application obtained from either the Apple Store or Google Play (each an “App Distributor”) to access the Site: