Low Flow Sample Clauses

Low Flow. If Gas is taken at a Delivery Point at rates less than the then-current Minimum Design Flow Rate to the extent that, in First Gas’ reasonable opinion, the Accuracy of the metered quantities at that Delivery Point is unduly adversely affected, First Gas shall notify the Interconnected Party accordingly. Unless the Interconnected Party can reasonably demonstrate to First Gas that those low Gas takes occurred during plant start-up and shut-down or were extraordinary occurrences and are unlikely to occur again, or that the Metering is Accurate event at those low Gas take rates, First Gas may: notify the Interconnected Party that it intends to modify the Metering to improve the Accuracy of metered quantities at low flow rates; and require the Interconnected Party to pay First Gas’ actual and reasonable costs to implement those modifications (reasonable evidence of which First Gas shall provide to the Interconnected Party), including via the payment of an Interconnection Fee or an increase in the current Interconnection Fee. Outage Notification The Interconnected Party shall as soon as reasonably practicable notify First Gas of any scheduled or unscheduled outages affecting such Interconnected Party in relation to its take of Gas at the Delivery Point. Such notice shall include: whether it is, or is expected to be, a full or partial outage and the likely duration of that outage; for scheduled outages, when such outage is expected to commence; in a reasonable amount of detail, the reason for that outage; and the extent of the expected reduction in the take of Gas. First Gas shall promptly publish on XXXXX the information provided by the Interconnected Party under section 3.6(a) and (b). metering and energy quantity reports Metering Required Except where otherwise provided pursuant to section 5.2 of the Code, First Gas will install Metering in respect of Delivery Points as set out in ICA Schedule One and use reasonable endeavours to ensure that it operates at all times. First Gas is to ensure that the design, construction, installation, operation and maintenance of the Metering complies with the Metering Requirements. Direct Gas Measurement Only Metering shall determine Gas quantities by direct measurement only and not by difference or by other indirect means. Testing of Metering and Provision of Information First Gas shall use reasonable endeavours, including by means of periodic testing in accordance with the Metering Requirements, to ensure that Metering is Acc...
AutoNDA by SimpleDocs
Low Flow. If Gas is injected at a Receipt Point at rates less than the then-current Minimum Design Flow Rate to the extent that, in First Gas’ reasonable opinion, the Accuracy of the metered quantities at that Receipt Point is adversely affected, First Gas shall notify the Interconnected Party accordingly. Unless the Interconnected Party can reasonably demonstrate to First Gas that those low Gas injection rates occurred during plant start-up and shut-down or were extraordinary occurrences and are unlikely to occur again, or that the Metering is Accurate even at those low Gas injection rates, First Gas may require the Interconnected Party at its cost to modify the Metering to improve the Accuracy of metered quantities at low flow rates, and: the Interconnected Party shall then implement appropriate modifications as soon as practicable; and during the time required to modify the Metering, First Gas shall be entitled to suspend the Interconnected Party’s right to inject Gas at that Receipt Point.
Low Flow. (a) Only systems with both of the following conditions must meet the low flow performance criteria in (b) and (c), below.
Low Flow. 3.6 3.5 If Gas is taken at a Delivery Point at rates less than the then-current Minimum Design Flow Rate to the extent that, in First Gas’ reasonable opinion, the Accuracy of the metered quantities at that Delivery Point is undulyadversely affected, First Gas shall notify the Interconnected Party accordingly. Unless the Interconnected Party can reasonably demonstrate to First Gas that those low Gas takes occurred during plant start-up and shut-down or were extraordinary occurrences and are unlikely to occur again, or that the Metering is Accurate even at those low Gas take rates, First Gas may:
Low Flow. If Gas is injected at a Receipt Point at rates less than the Minimum Design Flow Rate to the extent that, in First Gas’ reasonable opinion, the Accuracy of the energy quantities injected at that Receipt Point is compromised, First Gas shall notify the Interconnected Party accordingly. Following notification pursuant to section 2.11, unless the Interconnected Party can reasonably demonstrate to First Gas that those low Gas injection rates were extraordinary occurrences that are not expected to occur to the same extent again, and/or that the Metering is Accurate even at those low flows: First Gas may give notice to the Interconnected Party requiring that it modify the Metering to ensure it is Accurate at those low flow rates; and the Interconnected Party shall then implement appropriate modifications at its cost as soon as practicable; and during the time required to modify the Metering First Gas’ shall be entitled to suspend the Interconnected Party’s right to inject Gas at that Receipt Point. metering and energy quantity reports Metering Required The Metering Owner shall install Metering as set out in Schedule One and use reasonable endeavours to ensure that it operates at all times. Direct Gas Measurement Only Metering shall determine Gas quantities by direct measurement only and not by difference or by other indirect means. Testing of Metering and Provision of Information The Metering Owner shall: no earlier than 3 Months before Metering is placed into service, test each meter and other gas measurement device forming part of that Metering; and where the Metering includes a verification meter, conduct an in-situ verification test of each custody transfer meter as soon as practicable after the Metering is placed into service,
Low Flow. 3.4 3.5 If Gas is injected at a Receipt Point at rates less than the then-current Minimum Design Flow Rate to the extent that, in First Gas’ reasonable opinion, the Accuracy of the metered quantities at that Receipt Point is undulyadversely affected, First Gas shall notify the Interconnected Party accordingly. Unless the Interconnected Party can reasonably demonstrate to First Gas that those low Gas injection rates occurred during plant start-up and shut-down or were extraordinary occurrences and are unlikely to occur again, or that the Metering is Accurate even at those low Gas injection rates, First Gas may require the Interconnected Party at its cost to modify the Metering to improve the Accuracy of metered quantities at low flow rates, and:

Related to Low Flow

  • Follow-up Follow up initial solicitations of interest by contacting the SBEs to determine with certainty whether the enterprises are interested in performing specific items involved in work.

  • Flow Down For all Covered Transactions, including all tiers of subcontracts and subawards, the Recipient shall:

  • CAISO Scheduling Coordinator Charge The CAISO Scheduling Coordinator Charge for each Unit shall be the product of $0.31 and the Unit’s Billable MWh for the Billing Month.

  • Follow-up Testing An employee shall submit to unscheduled follow-up drug and/or alcohol testing if, within the previous 24-month period, the employee voluntarily disclosed drug or alcohol problems, entered into or completed a rehabilitation program for drug or alcohol abuse, failed or refused a preappointment drug test, or was disciplined for violating the provisions of this Agreement and Employer work rules. The Employer may require an employee who is subject to follow-up testing to submit to no more than six unscheduled drug or alcohol tests within any 12 month period.

  • Cash Flow Multi-Year Cash Flow = ( ) − ( ); One-Year Cash Flow = ( ) − ( ) Preliminary Rating Final Rating (Following Additional Analysis)

  • Low Census Low census is defined as a decline in patient care requirements resulting in a temporary staff decrease. During periods of low census, the Employer will assign low census to nurses in the following order:

  • Flow Down Clauses: The Consultant shall require this provision in each subcontract of any tier.

  • INTERIM MAINTENANCE PERIOD During the interim maintenance period between obtaining of the completion certificate of Project and formation and operationalization of the Association the Promoter shall through itself or through a facility management company constitute a committee to run, operate, manage and maintain the Common Areas.

  • REVERSE FLOW PROGRAMS The State is not required to cover any reverse flow programs under the terms of this Agreement because the State does not participate in the program.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

Time is Money Join Law Insider Premium to draft better contracts faster.