Solar Home System Hardware Description Sample Clauses

Solar Home System Hardware Description. 1.1. The Solar Home System (SHS) is intended to provide the user with a convenient means of supplying power for small electrical loads such as lights, radio/cassette players or TV. A typical SHS operates at a rated voltage of 12 Vdc and provides power for fluorescent luminaries, radio/cassette players, small black and white TV or similar low-power appliance for about three to five hours a day. Additionally, other types of luminaries, 12 Vdc or lower voltage DC/DC converter outlets or a DC/AC inverter may be supplied as options. Each SHS consists of one or more photovoltaic (PV) modules, each having minimum output of 30 Wp charging a 12 Vdc lead-acid battery along with luminaries, related electronic and electrical components and mounting hardware. 1.2. The system should be designed to have at least three days autonomy (i.e. can run for three consecutive days without charging from the panel). 1.3. The SHS is packaged to provide convenient installation at a remote customer home site by a qualified technician. The system is constructed such that a user can perform routine maintenance such as adding battery water and replacing light bulbs and fuses, and a technician can easily perform system diagnostics or replace components.
AutoNDA by SimpleDocs

Related to Solar Home System Hardware Description

  • GENERAL SERVICE DESCRIPTION Service Provider currently provides active medical, pharmacy(Rx) and dental administration for coverages provided through Empire and Anthem (medical), Medco(Rx), MetLife(dental) and SHPS (FSA) (Empire, Anthem, Medco, MetLife and SHPS collectively, the “Vendors”) for its U.S. Active, Salaried, Eligible Employees (“Covered Employees”). Service Provider shall keep the current contracts with the Vendors and the ITT CORPORATION SALARIED MEDICAL AND DENTAL PLAN (PLAN NUMBER 502 EIN 00-0000000) and the ITT Salaried Medical Plan and Salaried Dental Plan General Plan Terms (collectively, the “Plans”) and all coverage thereunder in full force through December 31, 2011 for Service Recipient’s Covered Employees. All claims of Service Recipient’s Covered Employees made under the Plans and incurred on or prior to December 31, 2011 the (“2011 Plan Year”) will be adjudicated in accordance with the current contract and Service Provider will continue to take such actions on behalf of Service Recipient’s Covered Employees as if such employees are employees of Service Provider. All medical, dental, pharmacy and FSA claims of Service Recipient’s Covered Employees made under the Plans (the “Claims”) will be paid by the Vendors on behalf of the Service Provider. Service Recipient will pay Service Provider for coverage based on 2011 budget premium rates previously set for the calendar year 2011 and described in the “Pricing” section below. Service Recipient will pay Service Provider monthly premium payments for this service, for any full or partial months, based on actual enrollment for the months covered post-spin using enrollments as of the first (1st) calendar day of the month, commencing on the day after the Distribution Date. Service Recipient will prepare and deliver to Service Provider a monthly self xxxx containing cost breakdown by business unit and plan tier as set forth on Attachment A, within five (5) Business Days after the beginning of each calendar month. The Service Recipient will be required to pay the Service Provider the monthly premium payments within ten (10) Business Days after the beginning of each calendar month. A detailed listing of Service Recipient’s employees covered, including the Plans and enrollment tier in which they are enrolled, will be made available to Service Provider upon its reasonable request. Service Provider will retain responsibility for executing funding of Claim payments and eligibility management with Vendors through December 31, 2013. Service Provider will conduct a Headcount True-Up (as defined below) of the monthly premiums and establish an Incurred But Not Reported (“IBNR”) claims reserve for Claims incurred prior to December 31, 2011 date, but paid after that date, and conduct a reconciliation of such reserve. See “Headcount True-Up” and “IBNR Reconciliation” sections under Additional Pricing for details.

  • Service Description 2.1 General

  • System Description The wet detention basin is designed to trap 80% of sediment in runoff and maintain pre-development downstream peak flows. The basin has two forebays (smaller ponds) located at the low end of two grass xxxxxx. In addition to runoff conveyance, the grass xxxxxx also allow infiltration and filtering of pollutants, especially from smaller storms. The forebays are each 4 feet deep. They are connected to the main pool by 18 and 24-inch metal pipes that outlet onto a rock chute. The forebays will trap coarse sediments in runoff, such as road sands, thus reducing maintenance of the main basin. The main pool will trap the finer suspended sediment. To do this, the pond size, water level and outlet structures must be maintained as specified in this Agreement (see Figures 1, 2 and 3). The main basin receives runoff from a 67.1 acre drainage area (41.2 acres within the subdivision and 25.9 acres off-site drainage coming from the east). During high rainfall or snow melt events, the water level will temporarily rise and slowly drain down to the elevation of the control structure. The water level is controlled by a 12-inch concrete pipe extending through the berm in the northwest corner of the basin (see Figures 1 and 3). On the face of the 12-inch pipe, there is metal plate with a 3-inch drilled hole (orifice) with stone in front of it. This orifice controls the water level and causes the pond to temporarily rise during runoff events. Washed stone (1- 2” diameter) is placed in front of the orifice to prevent clogging. High flows may enter the grated concrete riser or flow over the rock lined emergency spillway. “As-built” construction drawings of the basin, showing actual dimensions, elevations, outlet structures, etc. will be recorded as an addendum(s) to this agreement within 60 days after [Municipality Name] accepts verification of construction from the project engineer.

  • Service Descriptions Credit Card processing services: Global Direct’s actions to the appropriate card associations and/or issuers (e.g., Visa, MasterCard, Diners, Discover); settlement; dispute resolution with cardholders’ banks; and transaction-related reporting, statements and products. Debit/ATM Processing Services: Global Direct has connected to the following debit card networks (“Networks”): Accel, AFFN, Interlink, MAC, Maestro, NYCE, Pulse, Star, and Tyme. Global Direct will provide Merchant with the ability to access the Networks that Global Direct has connected to for the purpose of authorizing debit card transactions at the point of sale from cards issued by the members of the respective Networks. Global Direct will provide connection to such Networks, terminal applications, settlement and reporting activities. EBT Transaction Processing Services: Global Direct offers electronic interfaces to Electronic Benefits Transfer (“EBT”) networks for the processing of cash payments or credits to or for the benefit of benefit recipients (“Recipients”). Global Direct will provide settlement and switching services for various Point of Sale transactions initiated through Merchant for the authorization of the issuance of the United States Department of Agriculture, Food and Nutrition Services (“FNS”) food stamp benefits (“FS Benefits”) and/or government delivered cash assistance benefits (“Cash Benefits, ”with FS Benefits, “Benefits”) to Recipients through the use of a state-issued card (“EBT Card”). With respect to Visa and MasterCard products, Merchant agrees to pay and Merchant's account(s) will be charged pursuant to Section 5 of this Agreement for any additional fees incurred as a result of Merchant's subsequent acceptance of transactions with any Visa or MasterCard product that it has not elected to accept.

  • Software Use Case Red Hat Enterprise Linux Developer Suite Subscription Services for Red Hat Enterprise Linux Developer Suite are available for Development Purposes only.

  • Computer Equipment Recycling Program If this Contract is for the purchase or lease of computer equipment, then Contractor certifies that it is in compliance with Subchapter Y, Chapter 361 of the Texas Health and Safety Code related to the Computer Equipment Recycling Program and the Texas Commission on Environmental Quality rules in 30 TAC Chapter 328.

  • Site Description {Buyer Comment: Provide a legal description of the Site, including the Site map.}

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • SERVICE LEVEL DESCRIPTION The Fund Accounting Agreement is hereby amended by deleting the Service Level Description attached thereto and replacing it in its entirety with the Service Level Description attached hereto.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!