SPECIFICATION FOR PORTABLE TOILET “MALE” BLOCK Sample Clauses

SPECIFICATION FOR PORTABLE TOILET “MALE” BLOCK. LAYOUT The exterior dimensions of the standard 20 ft ISO container is to be minimum20’x8’x8’ with a tolerance of +10%. Each toilet block should consist of 2 No EWC (Ceramic) + 1 No of IWC + 5 Nos Ceramic waterless urinals ( 4 for men and 1 for child ) and two numbers of wash basins with common dustbin & 1no of common looking mirror (Max. Size1700mm L x 900mm B x 5mm Thick) aesthetically fitted over washbasin area. Toilet Cubicle to be provided with one health faucet & 1 no Tissue Paper Holder. All internal accessories of Indian / EWC including washbasin to be made of Ceramic material including each Cistern. OUTER STRUCTURE Single extruded WPC {Wood Polymer Composite} solid plain sheet of 6mm which is UV printed {4 color} on the surface as per design approved by engineer in charge.UV digital printing to be done by fine 7pl head for high definition finish and later coated in matt acrylic coating to be of required size comprising of Virgin polymer, calcium carbonate and natural fibers {rice husk and wheat husk} and non toxic additives {maximum toxicity index of 12 grams for 100 grams} having a density of 600- 660 kg/m3, screw holding strength of 1800N {face} and 900N {edge}, minimum compressive strength of 50N/mm2, Tensile strength of 11 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category. Limiting Oxygen index of 39%, property of being termite and borer proof, water/moisture proof, fire retardant. OUTER STRUCTURE ROOF ON TOP Single extruded WPC {Wood Polymer Composite} solid plain sheet of 4mm.WPC sheet to be pasted over GI solid sheet of 1 mm{corrosion free}, GI sheet will be fastened to MS hollow tubes{1x1,2x2 inches} of required size. On the top of WPC sheets would be covering of Roof tile. WPC comprising of Virgin polymer, calcium carbonate and natural fibers {rice husk and wheat husk} and non toxic additives {maximum toxicity index of 12 grams for 100 grams} having a density of 600- 660 kg/m3, screw holding strength of 1800N {face} and 900N {edge}, minimum compressive strength of 50N/mm2, Tensile strength of 11 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category. Limiting Oxygen index of 39%, property of being termite and borer proof, water/moisture proof, fire INNER WALL AND CLADDING Single extruded WPC {Wood polymer Composite} solid 5mm wall cladding for pasting and finishing any type of wall, ceiling, column cladding, staircase wall, lift lobby walls, reception area, to...
AutoNDA by SimpleDocs

Related to SPECIFICATION FOR PORTABLE TOILET “MALE” BLOCK

  • ODUF Packing Specifications 6.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • Escrow Format Specification Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Minimum Site Requirements for TIPS Sales (when applicable to TIPS Sale). Cleanup: When performing work on site at a TIPS Member’s property, Vendor shall clean up and remove all debris and rubbish resulting from their work as required or directed by the TIPS Member or as agreed by the parties. Upon completion of work, the premises shall be left in good repair and an orderly, neat, clean and unobstructed condition. Preparation: Vendor shall not begin a project for which a TIPS Member has not prepared the site, unless Vendor does the preparation work at no cost, or until TIPS Member includes the cost of site preparation in the TIPS Sale Site preparation includes, but is not limited to: moving furniture, installing wiring for networks or power, and similar pre‐installation requirements. Registered Sex Offender Restrictions: For work to be performed at schools, Vendor agrees that no employee of Vendor or a subcontractor who has been adjudicated to be a registered sex offender will perform work at any time when students are, or reasonably expected to be, present unless otherwise agreed by the TIPS Member. Vendor agrees that a violation of this condition shall be considered a material breach and may result in the cancellation of the TIPS Sale at the TIPS Member’s discretion. Vendor must identify any additional costs associated with compliance of this term. If no costs are specified, compliance with this term will be provided at no additional charge. Safety Measures: Vendor shall take all reasonable precautions for the safety of employees on the worksite, and shall erect and properly maintain all necessary safeguards for protection of workers and the public. Vendor shall post warning signs against all hazards created by the operation and work in progress. Proper precautions shall be taken pursuant to state law and standard practices to protect workers, general public and existing structures from injury or damage. Smoking: Persons working under Agreement shall adhere to the TIPS Member’s or local smoking statutes, codes, ordinances, and policies.

  • Packing Specifications 7.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • Flexible Work Schedule A flexible work schedule is any schedule that is not a regular, alternate, 9/80, or 4/10 work schedule and where the employee is not scheduled to work more than 40 hours in the "workweek" as defined in Subsections F. and H., below.

  • SERVICE LEVEL DESCRIPTION The Fund Accounting Agreement is hereby amended by deleting the Service Level Description attached thereto and replacing it in its entirety with the Service Level Description attached hereto.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Flexible Work Schedules An employee may request a modification of their current work schedule to another schedule. The Employer, or its designees, may approve or deny flexible work schedules and retain the responsibility for determining exemptions from, or terminations of, flexible work schedules which adversely affect the operation of the Minnesota Judicial Branch or the level of service to the public.

  • Drug-Free Workplace Certification As required by Executive Order No. 90-5 dated April 12, 1990, issued by the Governor of Indiana, the Company hereby covenants and agrees to make a good faith effort to provide and maintain a drug-free workplace at the Project Location. The Company will give written notice to the IEDC within ten (10) days after receiving actual notice that the Company, or an employee of the Company in the State of Indiana, has been convicted of a criminal drug violation occurring in the workplace. False certification or violation of this certification may result in sanctions including, but not limited to, suspension of payments under the Agreement, termination of the Agreement and/or debarment of contracting opportunities with the State for up to three (3) years. In addition to the provisions of the above paragraph, if the total amount set forth in the Agreement is in excess of $25,000.00, the Company agrees that it will provide a drug-free workplace by: A. Publishing and providing to all of its employees a statement notifying them that the unlawful manufacture, distribution, dispensing, possession or use of a controlled substance is prohibited in the Company’s workplace, and specifying the actions that will be taken against employees for violations of such prohibition;

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!