Program Objectives Implement a rigorous constructability program following The University of Texas System, Office of Facilities Planning and Construction Constructability Manual. Identify and document project cost and schedule savings (targeted costs are 5% of construction costs). Clarification of project goals, objectives.
Goals & Objectives The purpose of this Agreement is to ensure that the proper elements and commitments are in place to provide consistent IT service support and delivery to the Customer by Centre. The goal of this Agreement is to obtain mutual agreement for IT service provision between Centre and Customer. The objectives of this Agreement are to: Provide clear reference to service ownership, accountability, roles and/or responsibilities. Present a clear, concise and measurable description of service provision to the Customer. Match perceptions of expected service provision with actual service support & delivery.
PERFORMANCE MANAGEMENT SYSTEM 6.1 The Performance Plan (Annexure A) to this Agreement sets out – 6.1.1 The standards and procedures for evaluating the Employee’s performance; and 6.1.2 The intervals for the evaluation of the Employee’s performance. 6.2 Despite the establishment of agreed intervals for evaluation, the Employer may in addition review the Employee’s performance at any stage while the contract of employment remains in force; 6.3 Personal growth and development needs identified during any performance review discussion must be documented in a Personal Development Plan as well as the actions agreed to and implementation must take place within set time frames; 6.4 The Employee’s performance will be measured in terms of contributions to the goals and strategies set out in the Employer’s Integrated Development Plan (IDP) as described in 6.6 – 6.12 below; 6.5 The Employee will submit quarterly performance reports (SDBIP) and a comprehensive annual performance report at least one week prior to the performance assessment meetings to the Evaluation Panel Chairperson for distribution to the panel members for preparation purposes; 6.6 Assessment of the achievement of results as outlined in the performance plan: 6.6.1 Each KPI or group of KPIs shall be assessed according to the extent to which the specified standards or performance targets have been met and with due regard to ad-hoc tasks that had to be performed under the KPI, and the score of the employer will be given to and explained to the Employee during the assessment interview. 6.6.2 A rating on the five-point scale shall be provided for each KPI or group of KPIs which will then be multiplied by the weighting to calculate the final score; 6.6.3 The Employee will submit his self-evaluation to the Employer prior to the formal assessment; 6.6.4 In the instance where the employee could not perform due to reasons outside the control of the employer and employee, the KPI will not be considered during the evaluation. The employee should provide sufficient evidence in such instances; and 6.6.5 An overall score will be calculated based on the total of the individual scores calculated above.
Performance Management 17.1 The Contractor will appoint a suitable Account Manager to liaise with the Authority’s Strategic Contract Manager. Any/all changes to the terms and conditions of the Agreement will be agreed in writing between the Authority’s Strategic Contract Manager and the Contractor’s appointed representative. 17.2 The Contractor will ensure that there will be dedicated resources to enable the smooth running of the Framework Agreement and a clear plan of contacts at various levels within the Contractor's organisation. Framework Public Bodies may look to migrate to this Framework Agreement as and when their current contractual arrangements expire. The Contractor will where necessary assign additional personnel to this Framework Agreement to ensure agreed service levels are maintained and to ensure a consistent level of service is delivered to all Framework Public Bodies. 17.3 In addition to annual meetings with the Authority's Strategic Contract Manager, the Contractor is expected to develop relationships with nominated individuals within each of the Framework Public Bodies to ensure that the level of service provided on a local basis is satisfactory. Where specific problems are identified locally, the Contractor will attempt to resolve such problems with the nominated individual within that organisation. The Authority's Strategic Contract Manager will liaise (or meet as appropriate) regularly with the Framework Public Bodies' Contract Manager, and where common problems are identified, it will be the responsibility of the Contractor to liaise with the Authority's Strategic Contract Manager to agree a satisfactory course of action. Where the Contractor becomes aware of a trend that would have a negative effect on one or more of the Framework Public Bodies, they should immediately notify the Authority's Strategic Contract Manager to discuss corrective action. 17.4 Regular meetings, frequency to be advised by Framework Public Body, will be held between the Framework Public Bodies' Contract Manager and the Contractor's representative to review the performance of their Call-Off Contract(s) under this Framework Agreement against the agreed service levels as measured through Key Performance Indicators (KPIs). Reports will be provided by the Contractor to the Framework Public Bodies' Contract Manager at least 14 days prior to the these meetings. 17.5 Performance review meetings will also be held annually, between the Authority's Strategic Contract Manager and the Contractor's representative to review the performance of the Framework Agreement against the agreed service levels as measured through Key Performance Indicators. A summary of the quarterly reports will be provided by the Contractor at least 14 days prior to these meetings. 17.6 The Authority will gather the outputs from contract management to review under the areas detailed in the table below. Provision of management reports 90% to be submitted within 10 working days of the month end Report any incident affecting the delivery of the Service(s) to the Framework Public Body 100% to be reported in writing to FPB within 24 hours of the incident being reported by telephone/email Prompt payment of sub-contractors and/or consortia members (if applicable). Maximum of 30 from receipt of payment from Framework Public Bodies, 10 days target 100% within 30 days
Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.
Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.
Target Population TREATMENT FOR ADULT (TRA) Target Population
Statewide HUB Program Statewide Procurement Division Note: In order for State agencies and institutions of higher education (universities) to be credited for utilizing this business as a HUB, they must award payment under the Certificate/VID Number identified above. Agencies, universities and prime contractors are encouraged to verify the company’s HUB certification prior to issuing a notice of award by accessing the Internet (xxxxx://xxxxx.xxx.xxxxx.xx.xx/tpasscmblsearch/index.jsp) or by contacting
Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.
Benchmarks for Measuring Accessibility For the purposes of this Agreement, the accessibility of online content and functionality will be measured according to the W3C’s Web Content Accessibility Guidelines (WCAG) 2.0 Level AA and the Web Accessibility Initiative Accessible Rich Internet Applications Suite (WAI-ARIA) 1.0 for web content, which are incorporated by reference.