Type 2-B Interconnection Sample Clauses

Type 2-B Interconnection. Upon request from ALLTEL Wireless, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between RLEC's Stand-Alone End Office Switch or Host End Office Switch and ALLTEL Wireless' point of presence in the RLEC's telephone exchange, with the POI designated at the RLEC's Stand-Alone End Office Switch or Host End Office Switch. These trunk groups would be provisioned in connection with ALLTEL Wireless' NPA/NXX codes located within a RLEC exchange served by the End Office Switch, provided that ALLTEL Wireless has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by RLEC to ALLTEL Wireless as described in Section 5.4.5 below.
AutoNDA by SimpleDocs
Type 2-B Interconnection. Upon request from Western Wireless, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between RLEC's Stand-Alone End Office Switch or Host End Office Switch and Western Wireless' point of presence in the RLEC's telephone exchange, with the POI designated at the RLEC's Stand-Alone End Office Switch or Host End Office Switch. These trunk groups would be provisioned in connection with Western Wireless' NPA/NXX codes located within a RLEC exchange served by the End Office Switch, provided that Western Wireless has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by RLEC to Western Wireless as described in Section 5.4.5 below.
Type 2-B Interconnection. Upon request from Pinpoint, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between RLEC's Stand-Alone End Office Switch or Host End Office Switch and Pinpoint' point of presence in the RLEC's telephone exchange, with the POI designated at the RLEC's Stand-Alone End Office Switch or Host End Office Switch. These trunk groups would be provisioned in connection with Pinpoint' NPA/NXX codes located within a RLEC exchange served by the End Office Switch provided that Pinpoint has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by RLEC to Pinpoint as described in Section 5.4.5 below.
Type 2-B Interconnection. Upon request from NECC, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between a Great Plains' End Office Switch and NECC' point of presence in the Great Plains' telephone exchange, with the POI designated at the Great Plains' End Office Switch. This trunk group would be provisioned in connection with NECC' NPA/NXX codes located within the Great Plains exchange, provided that NECC has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by Great Plains to NECC as described in Section 5.4.5 below.
Type 2-B Interconnection. Upon request from ALLTEL Wireless, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between a Great Plains' End Office Switch and ALLTEL Wireless' point of presence in the Great Plains' telephone exchange, with the POI designated at the Great Plains' End Office Switch. This trunk group would be provisioned in connection with ALLTEL Wireless' NPA/NXX codes located within the Great Plains exchange, provided that ALLTEL Wireless has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by Great Plains to ALLTEL Wireless as described in Section 5.4.5 below.
Type 2-B Interconnection. Upon request from VerizonWireless, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between a Great Plains' End Office Switch and VerizonWireless' point of presence in the Great Plains' telephone exchange, with the POI designated at the Great Plains' End Office Switch. This trunk group would be provisioned in connection with VerizonWireless' NPA/NXX codes located within the Great Plains exchange, provided that VerizonWireless has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by Great Plains to VerizonWireless as described in Section 5.4.5 below.
Type 2-B Interconnection. Upon request from BLAZE, the Parties agree to establish a Type 2-B Interconnection. A Type 2-B interconnection will be provided via a two-way trunk group between Cambridge's Stand-Alone End Office Switch or Host End Office Switch and BLAZE's point of presence in the Cambridge's telephone exchange, with the POI designated at the Cambridge's Stand-Alone End Office Switch or Host End Office Switch. These trunk groups would be provisioned in connection with BLAZE's NPA/NXX codes located within a Cambridge exchange served by the End Office Switch, provided that BLAZE has facilities to serve such customers. Applicable tariff charges for establishing and provisioning this trunk group will be billed by Cambridge to BLAZE as described in Section 5.4.5 below.
AutoNDA by SimpleDocs

Related to Type 2-B Interconnection

  • SS7 Network Interconnection 9.7.1 SS7 Network Interconnection is the interconnection of Global Connection local signaling transfer point switches or Global Connection local or tandem switching systems with BellSouth signaling transfer point switches. This interconnection provides connectivity that enables the exchange of SS7 messages among BellSouth switching systems and databases, Global Connection local or tandem switching systems, and other third-party switching systems directly connected to the XxxxXxxxx XX0 network.

  • Network Interconnection 26.1 Interconnection between the networks of different SERVICE PROVIDERs shall be as per National Standards of CCS No.7 issued from time to time by Telecom Engineering Centre (TEC) and also subject to technical feasibility and technical integrity of the Networks and shall be within the overall framework of interconnection regulations issued by the TRAI from time to time. However, if situation so arises, INTERCONNECTION with R2MF signaling may be permitted by LICENSOR.

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • One-Way Interconnection Trunks 2.3.1 Where the Parties have agreed to use One-Way Interconnection Trunks for the delivery of traffic from PCS to Verizon, PCS, at PCS’s own expense, shall:

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and VarTec, VarTec shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks and the Entrance Facility, on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs.

  • Interconnection Point The Service Provider is responsible for connecting to the LFC Network at the Interconnection Point. The LFC may only change an Interconnection Point if a change is necessary to protect the security or integrity of that Interconnection Point in order to maintain the continuity of supply of the Wholesale Services. In the event of any such change:

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Interconnection Points 8.5.1 The IP of a Party (“Receiving Party”) for Measured Internet Traffic delivered to the Receiving Party by the other Party shall be the same as the IP of the Receiving Party for Reciprocal Compensation Traffic under Section 7.1 above.

  • of Interconnection 2.1.1 Each Party, at its own expense, shall provide transport facilities to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA selected by ENT.

  • Interconnection Service Interconnection Service allows the Interconnection Customer to connect the Large Generating Facility to the Participating TO’s Transmission System and be eligible to deliver the Large Generating Facility’s output using the available capacity of the CAISO Controlled Grid. To the extent the Interconnection Customer wants to receive Interconnection Service, the Participating TO shall construct facilities identified in Appendices A and C that the Participating TO is responsible to construct. Interconnection Service does not necessarily provide the Interconnection Customer with the capability to physically deliver the output of its Large Generating Facility to any particular load on the CAISO Controlled Grid without incurring congestion costs. In the event of transmission constraints on the CAISO Controlled Grid, the Interconnection Customer's Large Generating Facility shall be subject to the applicable congestion management procedures in the CAISO Tariff in the same manner as all other resources.