Valley Stream Substation Sample Clauses

Valley Stream Substation. ‌ The modifications at the Valley Stream Substation include the construction of a new terminal to connect the Facility to the spare terminal location. This will require the installation of a second 138 kV Gas Circuit Breaker (“GCB”) in series with existing GCB-1450, to prevent the loss of the Facility and existing circuit 138-292 (X.X. Xxxxxxx) for the single element failure of GCB-1450. The following is a list of the major equipment to be installed at the substation: • One (1) 138 kV, 3000A, 63KA Gas Circuit Breaker, with associated foundation • One (1) 138 kV, 3000A Gang Operated Disconnect Switch, with associated structure and foundations • Three (3) 138 kV Potential Transformers, with associated structure andfoundations • One (1) 138 kV, 3000A Motor Operated Air Break Disconnect Switch, with associated structure and foundations • One (1) 138 kV, Gang Operated 3 Phase Grounding Switch, with associated structure and foundations • One (1) 138 kV UG termination structure and foundations
AutoNDA by SimpleDocs

Related to Valley Stream Substation

  • Interconnection 2.2.10 Startup Testing and Commissioning

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner.

  • Interconnection Customer Interconnection Facilities Interconnection Customer shall design, procure, construct, install, own and/or control Interconnection Customer Interconnection Facilities described in Appendix A, Interconnection Facilities, Network Upgrades and Distribution Upgrades, at its sole expense.

  • Dark Fiber Transport Dark Fiber Transport is defined as Dedicated Transport that consists of unactivated optical interoffice transmission facilities without attached signal regeneration, multiplexing, aggregation or other electronics. Except as set forth in Section 6.9.1 below, BellSouth shall not be required to provide access to Dark Fiber Transport Entrance Facilities pursuant to this Agreement.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and ICG, ICG shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks, and the Entrance Facility on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs.