Waste Water Collection System Sample Clauses

Waste Water Collection System. The various types of wastewaters from the Project will be collected and transported by the following facilities: (i) sumps and duplex regenerative sump pumps to receive drainage from the chemical feed area and the anion-cation regeneration area;
AutoNDA by SimpleDocs
Waste Water Collection System. The various types of wastewaters from the Project will be collected and transported by the following facilities: (i) sumps and duplex regenerative sump pumps to receive drainage from the chemical feed area and the anion-cation regeneration area; (ii) the primary softener tank drain, the sand filter backwash drain, the sodium zeolite softener regeneration rinse tank drain, and a special primary water treatment pump to accomodate those drains; (iii) sumps and acid resistant duplex pumps to accommodate the acid trench and chemical tank area; (iv) a surface drain and associated pumps to receive runoff from the coal storage area; (v) special drains, pumps and piping to permit boiler water to by-pass other boiler water drains and to be pumped directly to the evaporation ponds; (vi) special drainage ditches and culverts to direct all surface water runoff from the coal storage area to the evaporation ponds, and (vii) sumps and associated pumps and piping to permit oily wastes to be transported to the evaporation ponds.

Related to Waste Water Collection System

  • Distribution System The Transmission Owner’s facilities and equipment used to transmit electricity to ultimate usage points such as homes and industries directly from nearby generators or from interchanges with higher voltage transmission networks which transport bulk power over longer distances. The voltage levels at which Distribution Systems operate differ among areas. Distribution Upgrades – The additions, modifications, and upgrades to the Transmission Owner’s Distribution System at or beyond the Point of Interconnection to facilitate interconnection of the Small Generating Facility and render the transmission service necessary to effect the Interconnection Customer’s wholesale sale of electricity in interstate commerce.

  • Data Collection The grant recipient will be required to provide performance data reports on a schedule delineated within Section A of this contract, Specific Terms and Conditions.

  • Cost Responsibility for Interconnection Facilities and Distribution Upgrades 4.1 Interconnection Facilities 4.2 Distribution Upgrades

  • One-Way Interconnection Trunks 2.3.1 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from Onvoy to Frontier, Onvoy, at Xxxxx’s own expense, shall: 2.3.1.1 provide its own facilities for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA; and/or 2.3.1.2 obtain transport for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA (a) from a third party, or, (b) if Frontier offers such transport pursuant to a Frontier access Tariff, from Frontier. 2.3.2 For each Tandem or End Office One-Way Interconnection Trunk group for delivery of traffic from Onvoy to Frontier with a utilization level of less than sixty percent (60%) for final trunk groups and eighty-five percent (85%) for high usage trunk groups, unless the Parties agree otherwise, Onvoy will promptly submit ASRs to disconnect a sufficient number of Interconnection Trunks to attain a utilization level of approximately sixty percent (60%) for all final trunk groups and eighty-five percent (85%) for all high usage trunk groups. In the event Onvoy fails to submit an ASR to disconnect One-Way Interconnection Trunks as required by this Section, Frontier may disconnect the excess Interconnection Trunks or bill (and Onvoy shall pay) for the excess Interconnection Trunks at the rates set forth in the Pricing Attachment. 2.3.3 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from Frontier to Onvoy, Frontier, at Frontier’s own expense, shall provide its own facilities for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA.

  • Unbundled Sub-Loop Feeder 2.8.4.1 Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and cross-box (or other access point) that serves an end user location. 2.8.4.2 USLF utilized for voice traffic can be configured as 2-wire voice (USLF-2W/V) or 4-wire voice (USLF-4W/V). 2.8.4.3 USLF utilized for digital traffic can be configured as 2-wire ISDN (USLF-2W/I); 2-wire Copper (USLF-2W/C); 4-wire Copper (USLF-4W/C); 4-wire DS0 level loop (USLF-4W/D0); or 4-wire DS1 and ISDN (USLF-4W/DI). 2.8.4.4 USLF will provide access to both the equipment and the features in the BellSouth central office and BellSouth cross box necessary to provide a 2W or 4W communications pathway from the BellSouth central office to the BellSouth cross- box. This element will allow for the connection of Lightyear’s loop distribution elements onto BellSouth's feeder system.

  • Data Collection and Reporting 1. Grantee shall develop and use a local reporting unit that will provide an assigned location for all clients served within the Hospital. This information shall also be entered into Client Assignment and Registration (CARE)when reporting on beds utilized at the Hospital. 2. Grantee shall budget and report expenditure data on the CARE Report III, incorporated by reference and posted at: xxxxx://xxx.xxx.xxxxx.xxx/doing-business-hhs/provider- portals/behavioral-health-services-providers/behavioral-health-provider- resources/community-mental-health-contracts, within the Community Hospital strategy C.2.1.1 using line 764 - Project Private Beds. 3. Grantee shall ensure that patient registration, diagnostics, admission and discharge data is reported by using the CARE screens and action codes listed below: a. Screen: Campus-Based Assignments (Add/Change/Delete), Action Code: 305; b. Screen: Campus-Based Discharge/Community Placement (Add/Change/Delete), Action Code: 310; c. Screen: Joint Community Support Plan (Add/Change/Delete), Action Code: 312; d. Screen: Register Client, Action Code: 325; e. Screen: Diagnostics (Add/Change/Delete), Action Code: 330; f. Screen: Voluntary Admission and Commitment (Add/Change/Delete), Action Code 332; g. Screen: Campus-Based Residential Xxxx/Dorm (Add/Change/Delete), Action Code 615; and h. Screen: MH Bed Allocation Exception (Add/Change/Delete), Action Code 345. For details related to the use of these screens and action codes, Grantee can refer to the CARE Reference Manual which can be found under the CARE (WebCARE) section on the portal at: xxxxx://xxxxxxxxx.xxx.xxxxx.xx.xx/helpGuide/Content/16_CARE/CAREWebCARE%20Refere nce%20Manual.htm

  • Television Equipment Recycling Program If this Contract is for the purchase or lease of covered television equipment, then Contractor certifies that it is compliance with Subchapter Z, Chapter 361 of the Texas Health and Safety Code related to the Television Equipment Recycling Program.

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and PCS, PCS shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks and the Entrance Facility, on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs. 2.4.2 Prior to ordering any Two-Way Interconnection Trunks from Verizon, PCS shall meet with Verizon to conduct a joint planning meeting (“Joint Planning Meeting”). At that Joint Planning Meeting, each Party shall provide to the other Party originating Centium Call Second (Hundred Call Second) information, and the Parties shall mutually agree on the appropriate initial number of Two-Way End Office and Tandem Interconnection Trunks and the interface specifications at the Point of Interconnection (POI). Where the Parties have agreed to convert existing One-Way Interconnection Trunks to Two-Way Interconnection Trunks, at the Joint Planning Meeting, the Parties shall also mutually agree on the conversion process and project intervals for conversion of such One-Way Interconnection Trunks to Two-Way Interconnection Trunks. 2.4.3 Two-Way Interconnection Trunks shall be from a Verizon End Office or Tandem to a mutually agreed upon POI. 2.4.4 On a semi-annual basis, PCS shall submit a good faith forecast to Verizon of the number of End Office and Tandem Two-Way Interconnection Trunks that PCS anticipates Verizon will need to provide during the ensuing two (2) year period to carry traffic from PCS to Verizon and from Verizon to PCS. PCS’s trunk forecasts shall conform to the Verizon CLEC trunk forecasting guidelines as in effect at that time. 2.4.5 The Parties shall meet (telephonically or in person) from time to time, as needed, to review data on End Office and Tandem Two-Way Interconnection Trunks to determine the need for new trunk groups and to plan any necessary changes in the number of Two-Way Interconnection Trunks. 2.4.6 Two-Way Interconnection Trunks shall have SS7 Common Channel Signaling. The Parties agree to utilize B8ZS and Extended Super Frame (ESF) DS1 facilities, where available. 2.4.7 With respect to End Office Two-Way Interconnection Trunks, both Parties shall use an economic Centium Call Second (Hundred Call Second) equal to five (5). 2.4.8 Two-Way Interconnection Trunk groups that connect to a Verizon access Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.005 during the average time consistent busy hour. Two-Way Interconnection Trunk groups that connect to a Verizon local Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.01 during the average time consistent busy hour. Verizon and PCS shall engineer Two-Way Interconnection Trunks using BOC Notes on the LEC Networks SR-TSV-002275. 2.4.9 The performance standard for final Two-Way Interconnection Trunk groups shall be that no such Interconnection Trunk group will exceed its design blocking objective (B.005 or B.01, as applicable) for three

  • STUDENT TUITION RECOVERY FUND “The State of California established the Student Tuition Recovery Fund (STRF) to relieve or mitigate economic loss suffered by a student in an educational program at a qualifying institution, who is or was a California resident while enrolled, or was enrolled in a residency program, if the student enrolled in the institution, prepaid tuition, and suffered an economic loss. Unless relieved of the obligation to do so, you must pay the state-imposed assessment for the STRF, or it must be paid on your behalf, if you are a student in an educational program, who is a California resident, or are enrolled in a residency program, and prepay all or part of your tuition. You are not eligible for protection from the STRF, and you are not required to pay the STRF assessment, if you are not a California resident, or are not enrolled in a residency program.”

  • Data Collection, Processing and Usage The Company collects, processes and uses the International Participant’s personal data, including the International Participant’s name, home address, email address, and telephone number, date of birth, social insurance number or other identification number, salary, citizenship, job title, any shares of Common Stock or directorships held in the Company, and details of all Equity Awards or any other equity compensation awards granted, canceled, exercised, vested, or outstanding in the International Participant’s favor, which the Company receives from the International Participant or the Employer. In granting the Equity Award under the Plan, the Company will collect the International Participant’s personal data for purposes of allocating shares of Common Stock and implementing, administering and managing the Plan. The Company’s legal basis for the collection, processing and usage of the International Participant’s personal data is the International Participant’s consent.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!