Examples of Gas vents in a sentence
Gas vents: Cost includes installation of a large diameter boring installation of piping, installation of gravel pack, and filling of the annular space with low permeability material.
Gas vents supported only by the flashing and extend- ing above the roof more than five feet should be securely guyed or braced to withstand snow and wind loads.
Gas vents serving equipment on more than one floor, a single or common gas vent shall be permitted in multistory installations to vent Category I equipment located on more than one floor level, provided the venting system is designed and installed in accordance with this section and approved engineering methods.
Flue gas temperatures in the chimney shall not exceed the limits and durations employed during listing tests and as required by this code.(b) Gas vents.
Gas vents twelve (12) inches (300 mm) in size or smaller with listed caps shall be permitted to be terminated in accordance with Figure 5-2, provided they are at least eight (8) feet (2.4 m) from a vertical wall or similar obstruction.
Gas vents shall allow for the movement and adequate venting of landfill gases in order to prevent the buildup of explosive concentrations of gas and prevent lateral migration of gases beyond the boundaries of the landfill.
Gas Vents: Gas vents for gas-fired water heaters shall be Type B gas vents by MetalFab, Metalbesotos, Metalvent, Ampco, or Stacks.
Gas vents passing through an insulated assembly shall have a metal insulation shield a minimum 2” above insulation.
Gas vents 12 inches or smaller must terminate at least 8 feet from a vertical wall or other similar obstruction and have a minimum height (from highest roof penetration to lowest discharge opening) according to the Indiana State Building Code.
Gas vents supported only by the flashing and extending above the roof more than five feet should be securely guyed or braced to withstand snow and wind loads.