Applicable Offtake Requirements. 2.1 Subject to paragraphs 3, 5 and 6 of this Annex B-2, the Applicable Offtake Requirements are that, at the point of offtake from the National Grid Gas System: (a) the characteristics of Exit Gas shall be within the limits in Table A below; (b) Exit Gas shall not contain any liquid material which would interfere with the integrity or operation of the IUK System or any appliance which is an appliance of a description and type which a consumer might reasonably be expected to have connected to the National Grid Gas System; and (c) Exit Gas shall have no added odorant. TABLE A Characteristic Unit Minimum Maximum Gross Calorific Value MJ/Nm³ 38.9 44.6 Xxxxx Index MJ/Nm³ 49.8 54.25 Temperature oC 1.0 28.0 Hydrocarbon Dewpoint oC from 1 to 69 xxxx n/a -2.0 Water Dewpoint oC from 1 to 69 xxxx n/a -10.0 Oxygen Content ppm vol n/a 1000.0 Carbon Dioxide mol% n/a 2.5 Hydrogen Sulphide (including COS) ppm vol n/a 3.3 Total Sulphur mg/Nm³ n/a 30 Incomplete Combustion Factor n/a n/a 0.48 Soot index n/a n/a 0.6 Inert gases (including Carbon Dioxide and Nitrogen) mol% n/a n/a Nitrogen mol% n/a n/a Hydrogen ppm vol n/a 1000.0 2.2 The characteristics of gas made available for offtake from the National Grid Gas System at the CSEP will be determined in accordance with Annex C (Measurement Provisions). 2.3 The above Table A uses expressions and abbreviations which have meanings assigned to them in the Gas Safety (Management) Regulations 1996, schedule 3, and will be subject to future modification in accordance with clause 7 (Amendment Process) to ensure compliance with any relevant statutory gas requirement. 2.4 Either Operator may request the limits in Table A above in relation to Nitrogen and inert gases to be revised in accordance with clause 7 (Amendment Process). 2.5 In order to minimise the level of solid material (if any) contained in the Exit Gas, National Grid Gas and IUK shall each comply with any velocity control protocol which may be agreed between the Operators from time to time. To the extent that Exit Gas does contain any solid material, National Grid Gas and IUK agree to co-operate with each other to ensure the safe disposal of such material.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Applicable Offtake Requirements. 2.1 Subject to paragraphs 3, 5 and 6 of this Annex B-2, the Applicable Offtake Requirements are that, at the point of offtake from the National Grid Gas System:
(a) the characteristics of Exit Gas shall be within the limits in Table A below;
(b) Exit Gas shall not contain any liquid material which would interfere with the integrity or operation of the IUK System or any appliance which is an appliance of a description and type which a consumer might reasonably be expected to have connected to the National Grid Gas System; and
(c) Exit Gas shall have no added odorant. TABLE A Characteristic Unit Minimum Maximum Gross Calorific Value Value1 MJ/Nm³ 38.9 44.6 Xxxxx Index Index1 MJ/Nm³ 49.8 49.75 54.25 54.19 Temperature oC 1.0 28.0 Hydrocarbon Dewpoint oC from 1 to 69 xxxx n/a -2.0 Water Dewpoint oC from 1 to 69 xxxx n/a -10.0 Oxygen Content ppm vol n/a 1000.0 Carbon Dioxide mol% n/a 2.5 Hydrogen Sulphide (including COS) ppm vol n/a 3.3 Total Sulphur mg/Nm³ n/a 30 Incomplete Combustion Factor n/a n/a 0.48 Soot index n/a n/a 0.6 Inert gases (including Carbon Dioxide and Nitrogen) mol% n/a n/a Nitrogen mol% n/a n/a Hydrogen ppm vol n/a 1000.0
1. Reference temperatures – 0°C for volume and 25°C for combustion.
2.2 The characteristics of gas made available for offtake from the National Grid Gas System at the CSEP will be determined in accordance with Annex C (Measurement Provisions).
2.3 The above Table A uses expressions and abbreviations which have meanings assigned to them in the Gas Safety (Management) Regulations 1996, schedule 3, and will be subject to future modification in accordance with clause 7 (Amendment Process) to ensure compliance with any relevant statutory gas requirement.
2.4 Either Operator may request the limits in Table A above in relation to Nitrogen and inert gases to be revised in accordance with clause 7 (Amendment Process).
2.5 In order to minimise the level of solid material (if any) contained in the Exit Gas, National Grid Gas and IUK shall each comply with any velocity control protocol which may be agreed between the Operators from time to time. To the extent that Exit Gas does contain any solid material, National Grid Gas and IUK agree to co-operate with each other to ensure the safe disposal of such material.
Appears in 1 contract
Samples: Interconnection Agreement
Applicable Offtake Requirements. 2.1 Subject to paragraphs paragraphsparagraph 3, 5 and 6 of this Annex B-2, the Applicable Offtake Requirements are that, at the point of offtake from the National Grid Gas System:
(a) the characteristics of Exit Gas shall be within the limits in Table A below;
(b) Exit Gas shall not contain any liquid material which would interfere with the integrity or operation of the IUK IUKInterconnector System or any appliance which is an appliance of a description and type which a consumer might reasonably be expected to have connected to the National Grid Gas System; and
(c) Exit Gas shall have no added odorant. TABLE A Characteristic Unit Minimum Maximum Gross Calorific Value Value1 MJ/Nm³ 38.9 44.6 Xxxxx Index Index1 MJ/Nm³ 49.8 54.25 49.75 54.19 Temperature oC 1.0 28.0 2838.0 Hydrocarbon Dewpoint oC from 1 to 69 xxxx n/a -2.0 Water Dewpoint oC from 1 to at 69 xxxx n/a -10.0 Oxygen Content ppm vol n/a 1000.0 Carbon Dioxide mol% n/a 2.5 Hydrogen Sulphide (including COS) ppm vol n/a 3.3 Total Sulphur mg/Nm³ n/a 30 Incomplete Combustion Factor n/a n/a 0.48 Soot index n/a n/a 0.6 Inert gases (including Carbon Dioxide and Nitrogen) mol% n/a n/a Nitrogen mol% n/a n/a Hydrogen ppm vol n/a 1000.01000.0 Note:
1. Reference temperatures – 0°C for volume and 25°C for combustion
2.2 The characteristics of gas made available for offtake from the National Grid Gas System at the CSEP will be determined in accordance with Annex C (Measurement Provisions).
2.3 The above Table A uses expressions and abbreviations which have meanings assigned to them in the Gas Safety (Management) Regulations 1996, schedule 3, and will be subject to future modification in accordance with clause 7 (Amendment Process) to ensure compliance with any relevant statutory gas requirement.
2.4 Either Operator may request the limits in Table A above in relation to Nitrogen and inert gases to be revised in accordance with clause 7 (Amendment Process).
2.5 In order to minimise the level of solid material (if any) contained in the Exit Gas, National Grid Gas and IUK IUKInterconnector shall each comply with any velocity control protocol which may be agreed between the Operators from time to time. To the extent that Exit Gas does contain any solid material, National Grid Gas and IUK IUKInterconnector agree to co-operate with each other to ensure the safe disposal of such material.