Appropriation of Construction Performance Security Sample Clauses

Appropriation of Construction Performance Security. Upon occurrence of a Concessionaire Default or failure to meet any Condition Precedent or failure to make any payment to the Authority in accordance with this Agreement, the Authority shall, without prejudice to its other rights and remedies hereunder or in law, be entitled to encash and appropriate the Construction Performance Security as damages for such Concessionaire Default or failure to meet any Condition Precedent or failure to make any payment to the Authority. Subject to this Agreement being valid and in force in accordance with the terms hereof, upon such encashment and appropriation of the Construction Performance Security, the Concessionaire shall, within 30 (thirty) days thereof, replenish, in case of partial appropriation, to its original level the Construction Performance Security, and in case of appropriation of the entire Construction Performance Security provide a fresh Construction Performance Security valid for the duration of the Construction Performance Security Period. In the event that the Concessionaire fails to do so, the Authority shall be entitled to terminate this Agreement in accordance with Article
AutoNDA by SimpleDocs
Appropriation of Construction Performance Security. (a) Upon occurrence of a Concessionaire Default or failure to meet any Condition Precedent or failure to make any payment to the Authority in accordance with this Agreement, the Authority shall, without prejudice to its other rights and remedies hereunder or in law, be entitled to encash and appropriate the Construction Performance Security as damages for such Concessionaire Default or failure to meet any Condition Precedent or failure to make any payment to the Authority.
Appropriation of Construction Performance Security. Upon occurrence of a Concessionaire Default or failure to meet any Condition Precedent or failure to make any payment to the Authority in accordance with this Agreement, the Authority shall, without prejudice to its other rights and remedies hereunder or in law, be entitled to encash and appropriate the amounts due and payable as Damages from the Construction Performance Security as damages for such Concessionaire Default or failure to meet any Condition Precedent or failure to make any payment to the Authority, on failure to pay such Damages. Subject to this Agreement being valid and in force in accordance with the terms hereof, upon such encashment and appropriation of the Construction Performance Security, the Concessionaire shall, within 30 (thirty) days thereof, replenish, in case of partial appropriation, to its original level the Construction Performance Security, and in case of appropriation of the entire Construction Performance Security provide a fresh Construction Performance Security valid for the duration of the Construction Performance Security Period. In the event that the Concessionaire fails to do so, the Authority shall be entitled to terminate this Agreement in accordance with Article
Appropriation of Construction Performance Security. Upon a Project Company Default and subject to Clause 2.9 (Force Majeure), the Contracting Authority shall, without prejudice to its other rights and remedies hereunder, have the right to encash and appropriate the relevant amounts from the Construction Performance Security for the relevant Project Company Default.

Related to Appropriation of Construction Performance Security

  • Appropriation of Performance Security Upon occurrence of a Concessionaire Default, the Authority shall, without prejudice to its other rights and remedies hereunder or in law, be entitled to invoke, encash and appropriate the relevant amounts from the Performance Security as Damages for such Concessionaire Default. Upon such invocation, encashment and appropriation from the Performance Security, the Concessionaire shall, within [30 (thirty)] days thereof, replenish, in case of partial appropriation, to its original level the Performance Security, and in case of appropriation of the entire Performance Security provide a fresh Performance Security, as the case may be, and the Concessionaire shall, within the time so granted, replenish or furnish fresh Performance Security as aforesaid failing which the Authority shall be entitled to terminate this Agreement in accordance with Article 37. Upon replenishment or furnishing of a fresh Performance Security, as the case may be, as aforesaid, the Concessionaire shall be entitled to an additional Cure Period of [90 (ninety)] days for remedying the Concessionaire Default, and in the event of the Concessionaire not curing its default within such Cure Period, the Authority shall be entitled to invoke, encash and appropriate such Performance Security as Damages, and to terminate this Agreement in accordance with Article 37.

  • Completion of Construction (a) For the purposes of this Agreement, the terms "

  • MONITORING OF CONSTRUCTION 13.1 Monthly progress reports During the Construction Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Authority and the Independent Engineer a monthly report on progress of the Construction Works and shall promptly give such other relevant information as may be required by the Independent Engineer.

  • ICIF Construction The ICIF shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Parties agree on another mutually acceptable deadline, Interconnection Customer shall deliver to Transmission Provider and Transmission Owner “as-built” drawings, information and documents for the ICIF, such as: a one-line diagram, a site plan showing the Generating Facility and the ICIF, plan and elevation drawings showing the layout of the ICIF, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer’s step-up transformers, the facilities connecting the Generating Facility to the step-up transformers and the ICIF, and the impedances (determined by factory tests) for the associated step-up transformers and the Generating Facility. Interconnection Customer shall provide Transmission Provider and Transmission Owner with Interconnection Customer’s specifications for the excitation system, automatic voltage regulator, Generating Facility control and protection settings, transformer tap settings, and communications, if applicable.

  • Commencement and Completion of Construction The Company shall begin Construction Activities no later than January 1, 2014 (“Commencement Date”) and secure a final Certificate of Compliance by June 30, 2015 (hereinafter, “Completion Date”).

  • Definitions and Construction 1 1.1 Definitions.....................................................................................1 1.2

  • Commencement of Construction Construction of the Project will start within thirty (30) days after notification to the Developer by the Owner, or as soon thereafter as weather and ground conditions permit.

  • Definitions and Rules of Construction 1.1 Unless otherwise defined herein, the following capitalized terms shall have the following meanings:

  • DAF Construction The DAF shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Developer and Connecting Transmission Owner agree on another mutually acceptable deadline, the Developer shall deliver to the Connecting Transmission Owner and NYISO “as- built” drawings, information and documents for the DAF, such as: a one-line diagram, a site plan showing the Large Generating Facility and the DAF, plan and elevation drawings showing the layout of the DAF, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Developer’s step-up transformers, the facilities connecting the Large Generating Facility to the step-up transformers and the DAF, and the impedances (determined by factory tests) for the associated step-up transformers and the Large Generating Facility. The Developer shall provide to, and coordinate with, Connecting Transmission Owner and NYISO with respect to proposed specifications for the excitation system, automatic voltage regulator, Large Generating Facility control and protection settings, transformer tap settings, and communications, if applicable.