Breaker Failure Protection Sample Clauses

Breaker Failure Protection. Breaker failure protection shall be included for the 220 kV circuit breaker. The breaker failure protection on a circuit breaker shall be initiated by all the other protection devices which normally initiate tripping of that breaker. In the event of the circuit breaker failing to open within a pre-selected time, the breaker failure protection shall instigate tripping of all adjacent circuit breakers. It shall also incorporate provision for initiating tripping of any remote infeeds, via teleprotection channels over fibre optical communication Links, as appropriate. The position of each circuit breaker shall be monitored by two sets of current relays fed from the back-up protection current transformers. The relay outputs shall be connected in series in a "two out of two" arrangement. The relays shall have an operating time of approximately 10 msecs, and a consistent rest time of less than 15 msecs. The relays shall be capable of remaining in the operated position continuously and carrying twice the circuit rated current continuously. The operating time of the breaker failure protection shall be selected by means of timers with ranges of 50 to 500 msecs. There shall be two timers per circuit breaker. The timer tripping outputs shall be connected in a "two out of two" arrangement and shall energise both tripping coils of the adjacent circuit breakers. The timers shall be of static numeric design to minimise our travel. The circuit Breaker Failure Protection Relay or Scheme employed shall be able to employ both the Current Check and the Circuit Breaker Closed Status Criterion for correct operation of the Circuit Breaker Failure Protection. Initiation and Tripping of the Circuit Breaker Failure Protection shall be interlocked with the Circuit Breaker busbar disconnectors and the 220 kV Power Transformer Isolator. The Circuit Breaker Failure Protection Contacts for Tripping and initiating Breaker failure schemes for adjacent as well as remote Circuit Breakers shall be self reset. Circuit Breaker Lock-out Relays shall however be electrically reset.
AutoNDA by SimpleDocs

Related to Breaker Failure Protection

  • Fire Protection Contractor shall take adequate and reasonable precautions to protect the Work against damage by fire and smoke. For example, without limitation, Contractor shall do the following:

  • Anti-Dilution Protection (a) In the event, prior to the payment of this Note, Aspen shall issue any of its shares of Aspen Common Stock as a stock dividend or shall subdivide the number of outstanding shares of Aspen Common Stock into a greater number of shares, then, in either of such events, the shares obtainable pursuant to conversion of this Note shall be increased proportionately; and, conversely, in the event that Aspen shall reduce the number of outstanding shares of Aspen Common Stock by combining such shares into a smaller number of shares, then, in such event, the number of shares of Aspen Common Stock obtainable pursuant to the conversion of this Note shall be decreased proportionately. Any dividend paid or distributed upon Aspen Common Stock in shares of any other class of capital stock of Aspen or securities convertible into shares of Aspen Common Stock shall be treated as a dividend paid in Aspen Common Stock to the extent that the shares of Aspen Common Stock are issuable upon the conversion of the Note. In the event that Aspen shall pay a dividend consisting of the securities of any other entity or in cash or other property, upon conversion of this Note, the Holder shall receive the securities, cash, or property which the Holder would have been entitled to if the Holder had converted this Note immediately prior to the record date of such dividend. (b) In the event, prior to the payment of this Note, Aspen shall be recapitalized by reclassifying its outstanding Aspen Common Stock (other than into shares of common stock with a different par value, or by changing its outstanding shares of common stock to shares without par value), or in the event Aspen or a successor corporation, partnership, limited liability company or other entity (any of which is defined as a “Corporation”) shall consolidate or merge with or convey all or substantially all of its, or of any successor Corporation’s property and assets to any other Corporation or Corporations (any such other Corporation being included within the meaning of the term “successor Corporation” used in the context of any consolidation or merger of any other Corporation with, or the sale of all or substantially all of the property of any such other Corporation to, another Corporation or Corporations), or in the event of any other material change in the capital structure of Aspen or of any successor Corporation by reason of any reclassification, reorganization, recapitalization, consolidation, merger, conveyance or otherwise, then, as a condition of any such reclassification, reorganization, recapitalization, consolidation, merger or conveyance, a prompt, proportionate, equitable, lawful and adequate provision shall be made whereby the Holder of this Note shall thereafter have the right to receive, upon the basis and the terms and conditions specified in this Note, in lieu of the securities of Aspen theretofore issuable upon the conversion of this Note, such shares, securities or assets as may be issued or payable with respect to or in exchange for the number of securities of Aspen theretofore obtainable upon conversion of this Note as provided above had such reclassification, reorganization, recapitalization, consolidation, merger or conveyance not taken place; and in any such event, the rights of the Holder of this Note to any adjustment in the number of shares of Aspen Common Stock obtainable upon conversion of this Note, as provided, shall continue and be preserved in respect of any shares, securities or assets which the Holder becomes entitled to obtain. Notwithstanding anything herein to the contrary, this Section 3(b) shall not apply to a merger with a subsidiary provided Aspen is the continuing Corporation and provided further such merger does not result in any reclassification, capital reorganization or other change of the securities issuable under this Note. The foregoing provisions of this Section 3(b) shall apply to successive reclassification, capital reorganizations and changes of securities and to successive consolidation, mergers, sales or conveyances. (c) In the event Aspen, at any time while this Note shall remain outstanding, shall sell all or substantially all of its assets, or dissolve, liquidate, or wind up its affairs, prompt, proportionate, equitable, lawful and adequate provision shall be made as part of the terms of any such sale, dissolution, liquidation, or winding up such that the Holder of this Note may thereafter receive, upon exercise hereof, in lieu of the securities of Aspen which it would have been entitled to receive, the same kind and amount of any shares, securities or assets as may be issuable, distributable or payable upon any such sale, dissolution, liquidation or winding up with respect to each share of Aspen Common Stock; provided, however, that in the event of any such sale, dissolution, liquidation or winding up, the right to convert this Note shall terminate on a date fixed by Aspen, such date so fixed to be not earlier than 6:00 p.m., New York time, on the 30th day after the date on which notice of such termination of the right to convert this Note has been given by mail to the Holder of this Note at such Holder’s address as it appears on the books of Aspen.

  • System Protection To prevent compromise of systems which contain DSHS Data or through which that Data passes: a. Systems containing DSHS Data must have all security patches or hotfixes applied within 3 months of being made available. b. The Contractor will have a method of ensuring that the requisite patches and hotfixes have been applied within the required timeframes. c. Systems containing DSHS Data shall have an Anti-Malware application, if available, installed. d. Anti-Malware software shall be kept up to date. The product, its anti-virus engine, and any malware database the system uses, will be no more than one update behind current.

  • Eye Protection Where an employee is required by the College or by legislation, in order to perform his/her duties, to acquire and wear prescription eye protection, the employee shall provide the College with proof of purchase by March 1 each year and the College shall reimburse to such employee, on the first pay day of April in each year, up to a maximum of twenty dollars ($20.00); in situations other than the foregoing, the College, may in its discretion, (which discretion shall not be unreasonably exercised) reimburse such expense where it is recommended by the health and safety committee constituted under the Occupational Health and Safety Act.

  • Whistle Blowing Protection The Employer agrees to adhere to the whistle blowing protection pursuant to the

  • PICKET LINE PROTECTION 1. All teachers covered under this agreement shall have the right to refuse to cross or work behind a picket line unless the same is declared illegal by the Labour Relations Board or the Courts. Failure to cross such picket line shall not be considered a violation of this agreement nor shall it be grounds for disciplinary action by the Board. Any teacher refusing to cross or work behind such a picket line shall be considered to be absent from work without pay. 2. The Board shall not request, require, nor direct teachers covered under this agreement to do work or carry out duties normally performed by employees engaged in a strike, or locked out, nor shall teachers request, require, or direct pupils to carry out such duties.

  • POWER SURGE PROTECTION This Agreement provides power surge protection from the product date of purchase of the Covered Product in the absence of insurance coverage. If the Covered Product is damaged as a result of a power surge, We will replace the Covered Product in accordance with the terms herein. You may be required to submit proof of claim denial from Your insurer, if applicable.

  • System Protection Facilities The Interconnection Customer shall, at its expense, install, operate and maintain System Protection Facilities as a part of the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities. The Participating TO shall install at the Interconnection Customer's expense any System Protection Facilities that may be required on the Participating TO’s Interconnection Facilities or the Participating TO’s Transmission System as a result of the interconnection of the Large Generating Facility and the Interconnection Customer’s Interconnection Facilities.

  • Xxxxx Disaster Protection In accordance with the requirements of the Flood Disaster Protection Act of 1973 (42 U.S.C. 4001), the Subrecipient shall assure that for activities located in an area identified by the Federal Emergency Management Agency (FEMA) as having special flood hazards, flood insurance under the National Flood Insurance Program is obtained and maintained as a condition of financial assistance for acquisition or construction purposes (including rehabilitation).

  • Job Protection 15.9.1 Subject to 15.10 below, an employee returning from parental leave is entitled to resume work in the same position or a similar position to the one they occupied at the time of commencing parental leave. A similar position means a position: (a) At the equivalent salary, grading; (b) At the equivalent weekly hours of duty; (c) In the same location or other location within reasonable commuting distance; and (d) Involving responsibilities broadly comparable to those experienced in the previous position. 15.9.2 Where applicable, employees shall continue to be awarded increments when their incremental date falls during absence on parental leave.