Comfort Stations. 1. The Contractor is required to provide a minimum of one(1) “comfort station” located within the Contractor’s authorized response zones that are accessible to on-duty field-based personnel 24/7. Staff quarters may be utilized as a comfort station if it meets the requirements herein. At a minimum, these facilities shall: a. Be climate controlled (air conditioning and heat); b. Have adequate and comfortable seating to accommodate a complete on-duty crew; c. Have at least one operable toilet, sink, shower, microwave and refrigerator; d. Have at least one desk and task chair; e. Have data capability to enable patient care charting; and f. Have adequate accommodations to meet the needs of nursing mothers. 2. Any changes to the locations of Contractor’s comfort stations or local headquarters will be subject to approval of MVEMSA Executive Director. Such approval shall not be unreasonably withheld.
Appears in 2 contracts
Samples: Agreement With Oak Valley Hospital District for 9 1 1 Emergency Ambulance Services, Agreement With Oak Valley Hospital District for 9 1 1 Emergency Ambulance Services
Comfort Stations. 1. The Contractor is required to provide a minimum of one(1) “comfort station” located within the Contractor’s authorized response zones zone that are is accessible to on-duty field-field- based personnel 24/7. Staff quarters may be utilized as a comfort station if it meets the requirements herein. At a minimum, these facilities shall:
a. Be climate controlled (air conditioning and heat);
b. Have adequate and comfortable seating to accommodate a complete on-duty crew;
c. Have at least one operable toilet, sink, shower, microwave and refrigerator;
d. Have at least one desk and task chair;
e. Have data capability to enable patient care charting; and
f. Have adequate accommodations to meet the needs of nursing mothers.
2. Any changes to the locations of Contractor’s comfort stations or local headquarters will be subject to approval of MVEMSA Executive Director. Such approval shall not be unreasonably withheld.
Appears in 2 contracts
Samples: Ambulance Services Agreement, Ambulance Services Agreement
Comfort Stations. 1. The Contractor is required to provide a minimum of one(1) “comfort station” located within the Contractor’s authorized response zones zone that are accessible to on-duty field-based personnel 24/7. Staff quarters may be utilized as a comfort station if it meets the requirements herein. At a minimum, these facilities shall:
a. Be climate controlled (air conditioning and heat);
b. Have adequate and comfortable seating to accommodate a complete on-duty crew;
c. Have at least one operable toilet, sink, shower, microwave and refrigerator;
d. Have at least one desk and task chair;
e. Have data capability to enable patient care charting; and
f. Have adequate accommodations to meet the needs of nursing mothers.