DEMISING PARTITION Sample Clauses

DEMISING PARTITION a. 2-1/2” - 25 gauge metal studs at 24” on center.
AutoNDA by SimpleDocs
DEMISING PARTITION. A. 2-1/2” 20-GAUGE METAL STUDS 24” ON CENTER WITH SEISMIC BRACING U.N.O. B. 5/8” TYPE “X” DRYWALL, ONE LAYER EACH SIDE OF STUDS. C. R-8 BATT INSULATION IN WALL CAVITY. D. R-11 SOUND BLANKET 4’-0” EACH DIRECTION. E. SOUND BOOTS AT HVAC PENETRATIONS AT DEMISING WALLS. F. HEIGHT FROM FLOOR SLAB TO STRUCTURE ABOVE (GROUND FLOOR, 17’-0”, FLOORS 2-17, 13’-5”, 18TH FLOOR, 13’-11”). G. PARTITION TO BE TAPED SMOOTH AND SANDED TO RECEIVE PAINT OR WALLCOVERING. H. “L” METAL AT TERMINATION OF PARTITION AT CEILING. I. STRAIGHT LINE TERMINATION AT BUILDING COLUMNS. SOUND SEALED GASKET CLOSURE AT MULLION TERMINATION. J. STAGGER AND CAULK AROUND ELECTRICAL OUTLETS AND OTHER BOXES, CAULK AROUND CONDUIT AND OTHER THROUGH-THE-WALL PENETRATIONS. CAULK ENTIRE PERIMETER OF WALL AT FLOOR, EXTERIOR WALL AND CEILING, AND BETWEEN “L” METAL FINISHED DRYWALL AND INTERSECTED SURFACE.
DEMISING PARTITION. Full height partition from floor slab to underside of slab above. 25 gauge, 2-1/2" metal studs, 24" on center. One layer, 5/8" thick, type "X" gypsum board each side. Partition taped smooth to receive paint or wallcovering. Batt insulation (R-11) in cavity. Sound boot installed in partition between tenants.
DEMISING PARTITION. 1/2, 20 gauge metal studs 24" on center with seismic bracing, unless noted otherwise.
DEMISING PARTITION. Install the demising wall at the Building in accordance with Exhibit A. The demising partition will be 35/8” metal studs with one layer of 5/8” gypsum wall board on each side with 3 inch sound attenuation insulation. Partition will extend from the concrete floor to the underside of the steel deck in the location shown on Exhibit A. Wall will be finished ready for paint. Bathrooms: Install one (1) new men’s and one (1) new women’s bathroom, which will each include (1) one shower stall in each bathroom. Landlord will provide sufficient bathroom fixture counts as per code for a fully occupied building. Install one (1) gender neutral single stall bathroom. Bathroom Flooring: Bathrooms to receive ceramic tile flooring. Ceramic tile will be installed on the wet walls in the bathrooms.
DEMISING PARTITION. 8” x 20 gauge metal studs at 24” on center (unless floor structure or roof structure is higher than 19’-0” A.F.F.). 20 gauge is permitted if structure above is below 13’-6” A.F.F.
DEMISING PARTITION. A. 6" - 20 gauge steel studs at 16" on center
AutoNDA by SimpleDocs
DEMISING PARTITION. 1.1.1. 2 1 2" - 25 gauge metal studs - 24" on center
DEMISING PARTITION. 5/8” x 25 min. gauge metal studs @ 16” on center.
DEMISING PARTITION. ​ Install the demising wall at the Building in accordance with Exhibit A. The demising partition will be 35/8” metal studs with one layer of 5/8” gypsum wall board on each side with 3 inch sound attenuation insulation. Partition will extend from the concrete floor to the underside of the steel deck in the location shown on Exhibit A. Wall will be finished ready for paint.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!