Commercial Operation Date 6.4.1 The SPV shall ensure that the Project Commercial Operation Date is achieved on or prior to the Scheduled Commercial Operation Date. The SPV shall provide a written notice to MSEDCL at least 30 (thirty) days in advance intimating MSEDCL of the proposed date on which the Commercial Operation Date of a Unit or the Project is proposed to be achieved. 6.4.2 If the Commercial Operation Date for the Units having a capacity equivalent to at least 75% (seventy five percent) of the Contracted Capacity is achieved before the Scheduled Commercial Operation Date, then all Units in respect of which the Commercial Operation Date has been achieved prior to the Scheduled Commercial Operation Date would be eligible for incentives as follows: (a) the Unit(s) injecting energy at 11 kV /22 kV shall be given an incentive of Rs. 0.25/ kWh; and (b) the Unit(s) injecting energy at 33 kV shall be given an incentive of Rs. 0.15/ kWh, for the power sold to MSEDCL for the first 3 (three) years from the Commercial Operation Date. To receive such incentives from MSAPL, which shall be over and above the Tariff, the SPV shall follow the process agreed to by the SPV under the Implementation Agreement. 6.4.3 It is hereby clarified that the aforementioned incentive shall not be available: (i) in respect of any Unit if the Commercial Operation Date for such Unit has not been achieved prior to the Scheduled Commercial Operation Date; and (ii) if the aggregate capacity of the Units for which the Commercial Operation Date has been achieved prior to Scheduled Commercial Operation Date is less than 75% (seventy five percent) of the Contracted Capacity. 6.4.4 In the event that Commercial Operation Date for any of the Units is achieved after the Scheduled Commercial Operation Date, the SPV shall be liable to pay Liquidated Damages as per the provisions set out below. 6.4.5 Without prejudice to any other rights of MSEDCL under this PPA, in case one or more Units of the SPV are unable to achieve Commercial Operation Date within a period of 2 (two) months from the Scheduled Commercial Operation Date, the capacity of such Units shall be annulled, and the Contracted Capacity shall be reduced to that extent. For Illustration: The Project has a Contracted Capacity of 100 MW and comprises of 10 Units of 10 MW each. If at the end of the aforementioned period of 14 (fourteen) months from the Effective Date, the SPV has achieved Commissioning for only 8 out of 10 Units, then the Contracted Capacity of the Project will stand reduced for the capacity of the 2 Units which have not been Commissioned, i.e. the Contracted Capacity will be 80 (100 (original Contracted Capacity)) – 10 (capacity of each Unit)*2 (number of Units not Commissioned).
Availability Control Personal Data will be protected against accidental or unauthorized destruction or loss.
Commercial Operation (i) On or before December 31, 2021, Interconnection Customer must demonstrate commercial operation of all generating units. Demonstrating commercial operation includes achieving Initial Operation in accordance with Section 1.4 of Appendix 2 to this ISA and making commercial sales or use of energy, as well as, if applicable, obtaining capacity qualification in accordance with the requirements of the Reliability Assurance Agreement Among Load Serving Entities in the PJM Region.
Ability to Carry Out Obligations Company has the right, power, and authority to enter into and perform its obligations under this Agreement. The execution and delivery of this Agreement by Company and the performance by Company of its obligations hereunder will not cause, constitute, or conflict with or result in (a) any breach of violation or any of the provisions of or constitute a default under any license, indenture, mortgage, charter, instrument, articles of incorporation, bylaw, or other agreement or instrument to which Company is a party, or by which either of them may be bound, nor will any consents or authorizations of any party other than those hereto be required; (b) an event that would cause Company to be liable to any party; or (c) an event that would result in the creation or imposition of any lien, charge, encumbrance on any asset of Company.
Development Obligations 1. The College supports the development, production, and dissemination of copyrightable, trademarkable, patentable, and other intellectual properties by its employees. 2. It is understood that intellectual property developed by employees on or off College time, except for those materials for which the College had specifically contracted prior to June 9, 1998, shall remain the property of such employees, but shall continue to be used for the benefit of the College while the employee remains an employee of the College.
Parallel Operation Obligations Once the Small Generating Facility has been authorized to commence parallel operation, the Interconnection Customer shall abide by all rules and procedures pertaining to the parallel operation of the Small Generating Facility in the applicable control area, including, but not limited to: (1) the rules and procedures concerning the operation of generation set forth in the NYISO tariffs or ISO Procedures or the Connecting Transmission Owner’s tariff; (2) any requirements consistent with Good Utility Practice or that are necessary to ensure the safe and reliable operation of the Transmission System or Distribution System; and (3) the Operating Requirements set forth in Attachment 5 of this Agreement.
Effective Date; Duration; Continuance (a) This Agreement shall become effective on January 1, 2020. (b) Subject to prior termination pursuant to Section 8.2 below, this Agreement shall continue in force until the next annual renewal, and indefinitely thereafter, but only so long as the continuance after such date shall be specifically approved at least annually by vote of the Trustees or by a vote of a majority of the outstanding voting securities of the Fund, provided that in either event such continuance shall also be approved by the vote of a majority of the Trustees who are not “interested persons” (as such term is defined in the Investment Company Act) of any party to this Agreement cast in person at a meeting called for the purpose of voting on such approval. (c) Except to the extent that the Trust has obtained and/or relies upon an exemptive order of the Commission or a no-action letter of the staff of the Commission providing relief from the requirement to obtain shareholder approval of this Agreement, the required shareholder approval of this Agreement or any continuance of this Agreement shall be effective with respect to the Fund if a majority of the outstanding voting securities of the series (as defined in Rule 18f-2(h) under the Investment Company Act) of shares of the Fund votes to approve this Agreement or its continuance.
Commercial Diligence Pfizer will use Commercially Reasonable Efforts to Commercialize at least [**] in [**], where Pfizer or its designated Affiliates or sublicensees seek and receive Regulatory Approval for such [**]. Pfizer will have no other diligence obligations with respect to the Commercialization of Licensed Products except as otherwise set forth in this Agreement.
Securing Physical Facilities DST shall maintain systems located in DST facilities that host Fund Data or provide services under the Agreement in an environment that is designed to be physically secure and to allow access only to authorized individuals. A secure environment includes the availability of onsite security personnel on a 24 x 7 basis or equivalent means of monitoring locations supporting the delivery of services under the Agreement.
Facility Operations V. FACILITY OPERATION MON TUES WED THURS FRI SAT SUN A. Hours facility is open to public and employees 6A- 5:30P 6A -5:30P 6A -5:30P 6A -5:30P 6A -5:30P Closed Closed B. Hours facility is open to public and employees