Emergency Department Utilization Rate Sample Clauses

Emergency Department Utilization Rate. MCO is required to achieve an annual ten percent (10%) reduction in its Emergency Department utilization. (1) The MCO’s performance target for the Contract Year will be calculated based on a ten (10%) percent reduction of the previous calendar year’s emergency department visits per 1,000 Enrollee months rate. (2) Partial Scoring for ED Utilization Withhold Measure: Portion of Target Points. As required by Minnesota Statutes, § 256B.69, subd. 5a (g), a portion of the withhold target points will be awarded commensurate with the achieved reduction less than the targeted amount. The percentage of reduction will be calculated to the second decimal. The number of points will be awarded on the percentage reduction achieved. (3) When the target is reached for the ED Utilization withhold measure, DHS will continue to monitor performance to verify that the MCO’s percentage for the measure did not increase more than ten percent (10%) of the previous percentage.
AutoNDA by SimpleDocs

Related to Emergency Department Utilization Rate

  • Emergency Escalation Escalation is strictly for purposes of notifying and investigating possible or potential issues in relation to monitored services. The initiation of any escalation and the subsequent cooperative investigations do not in themselves imply that a monitored service has failed its performance requirements. Escalations shall be carried out between ICANN and Registry Operators, Registrars and Registry Operator, and Registrars and ICANN. Registry Operators and ICANN must provide said emergency operations departments. Current contacts must be maintained between ICANN and Registry Operators and published to Registrars, where relevant to their role in escalations, prior to any processing of an Emergency Escalation by all related parties, and kept current at all times.

  • Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.

  • Emergency/Declared Disaster Requirements In the event of an emergency or if Orange County is declared a disaster area by the County, state or federal government, this Contract may be subjected to unusual usage. The Contractor shall service the County during such an emergency or declared disaster under the same terms and conditions that apply during non-emergency/disaster conditions. The pricing quoted by the Contractor shall apply to serving the County’s needs regardless of the circumstances. If the Contractor is unable to supply the goods/services under the terms of the Contract, then the Contractor shall provide proof of such disruption and a copy of the invoice for the goods/services from the Contractor’s supplier(s). Additional profit margin as a result of supplying goods/services during an emergency or a declared disaster shall not be permitted. In the event of an emergency or declared disaster, emergency purchase order numbers will be assigned. All applicable invoices from the Contractor shall show both the emergency purchase order number and the Contract number.

  • Emergency Closure Where there is a temporary closure as a result of an immediate emergency or a planned temporary closure due to renovations, repairs, or moves, the Employer will: a) First offer to the affected employees the choice of taking either a vacation day or an unpaid leave of absence with no loss of seniority or benefits; thereafter, at the Employer's discretion, one of the following: b) Reassign staff to another location; c) Reschedule the lost hours within two (2) pay periods; or d) Decide not to do either (b) or (c), in which case employees shall still be paid for their regularly scheduled hours which they did not work as a result of the temporary layoff.

  • OFFICE OF MANAGEMENT AND BUDGET (OMB) AUDIT REQUIREMENTS The parties shall comply with the requirements of the Single Audit Act of 1984, P.L. 98-502, ensuring that the single audit report includes the coverage stipulated in 2 CFR 200.

  • Emergency Response Partners must develop, maintain, and carry out a response plan for public water system emergencies, including disease outbreaks, spills, operational failures, and water system contamination. Partners must notify DWS in a timely manner of emergencies that may affect drinking water supplies.

  • Please see the current Washtenaw Community College catalog for up-to-date program requirements Conditions & Requirements

  • Emergency Calls IP Phones need an additional power supply to operate. In the event of a power failure it is your responsibility to ensure you have the means to make emergency calls. In accordance with paragraph 13.2, we will not be liable for any loss or damage (financial or otherwise) where you fail to do so.

  • Emergency Care If you need emergency care, call 911 or go to the nearest hospital emergency room. If you are traveling outside our service area and need urgent care, call the Customer Service number provided in the chart above or visit our website and use the “Find A Doctor” feature to find a BlueCard provider.

  • Emergency Situation In the event of an emergency situation beyond our reasonable control, such as an "act of God," war, fire, or natural disaster, services involving your account could be available only in a modified or reduced form or could be entirely unavailable. Unless expressly prohibited by applicable law, you agree that we will have no liability to you for such modification, reduction, or unavailability of services caused by an emergency situation.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!