Common use of Entrance Facilities Clause in Contracts

Entrance Facilities. ACCESS Integrated may elect to place ACCESS Integrated- owned or ACCESS Integrated leased fiber entrance facilities into its Collocation Space. BellSouth will designate the point of interconnection in close proximity to the BellSouth Premises housing the Collocation Space, such as at an entrance manhole or a cable vault, which are physically accessible by both Parties. ACCESS Integrated will provide and place fiber cable in the entrance manhole of sufficient length to be pulled through conduit and into the splice location. ACCESS Integrated will provide and install a sufficient length of fire retardant riser cable, to which BellSouth will splice the entrance cable. The fire retardant riser cable will extend from the splice location to ACCESS Integrated’s equipment in ACCESS Integrated’s Collocation Space. In the event ACCESS Integrated utilizes a non-metallic, riser-type entrance facility, a splice will not be required. ACCESS Integrated must contact BellSouth for authorization and instruction prior to placing any entrance facility cable in an entrance manhole or cable vault. ACCESS Integrated is responsible for the maintenance of the entrance facilities. Nonrecurring charges for cable installation will be assessed on a per cable basis as set forth in Exhibit B upon receipt of ACCESS Integrated’s BFFO. Recurring charges for the cable support structure will be billed at the rates set forth in Exhibit B.

Appears in 2 contracts

Samples: The Agreement, The Agreement

AutoNDA by SimpleDocs

Entrance Facilities. ACCESS Integrated 5.6.1 Neutral Tandem may elect to place ACCESS Integrated- Neutral Tandem-owned or ACCESS Integrated Neutral Tandem leased fiber entrance facilities into its Collocation Space. BellSouth will designate the point of interconnection in close proximity to the BellSouth Premises housing the Collocation Space, such as at an entrance manhole or a cable vaultvault for Central Offices, which are is physically accessible by both Parties. ACCESS Integrated For Central Offices, Neutral Tandem will provide and place fiber cable in the entrance manhole of sufficient length to be pulled through conduit and into the splice location. ACCESS Integrated Neutral Tandem will provide and install a sufficient length of fire retardant riser cable, to which BellSouth will splice the entrance cable. The fire retardant riser cable will extend from the splice location to ACCESS IntegratedNeutral Tandem’s equipment in ACCESS IntegratedNeutral Tandem’s Collocation Space. In the event ACCESS Integrated Neutral Tandem utilizes a non-metallic, riser-type entrance facility, a splice will not be required. ACCESS Integrated For Remote Terminals Neutral Tandem will provide and place copper cable through conduit from the Remote Site Collocation Space to the feeder distribution interface. Such copper cable must be of sufficient length to reach the splice location for splicing by BellSouth. Neutral Tandem must contact BellSouth for authorization and instruction prior to placing any entrance facility cable in an entrance manhole or cable vault. ACCESS Integrated Neutral Tandem is responsible for the maintenance of the entrance facilities. Nonrecurring charges for cable installation will be assessed on a per cable basis as set forth in Exhibit B upon receipt of ACCESS IntegratedNeutral Tandem’s BFFO. Recurring charges for the cable support structure will be billed at the rates set forth in Exhibit B.

Appears in 2 contracts

Samples: dms.psc.sc.gov, dms.psc.sc.gov

AutoNDA by SimpleDocs

Entrance Facilities. ACCESS Integrated 5.6.1 ComSouth may elect to place ACCESS Integrated- ComSouth-owned or ACCESS Integrated ComSouth leased fiber entrance facilities into its Collocation Space. BellSouth will designate the point of interconnection in close proximity to the BellSouth Premises housing the Collocation Space, such as at an entrance manhole or a cable vaultvault for Central Offices, which are is physically accessible by both Parties. ACCESS Integrated For Central Offices, ComSouth will provide and place fiber cable in the entrance manhole of sufficient length to be pulled through conduit and into the splice location. ACCESS Integrated ComSouth will provide and install a sufficient length of fire retardant riser cable, to which BellSouth will splice the entrance cable. The fire retardant riser cable will extend from the splice location to ACCESS IntegratedComSouth’s equipment in ACCESS IntegratedComSouth’s Collocation Space. In the event ACCESS Integrated ComSouth utilizes a non-metallic, riser-type entrance facility, a splice will not be required. ACCESS Integrated For Remote Terminals ComSouth will provide and place copper cable through conduit from the Remote Site Collocation Space to the feeder distribution interface. Such copper cable must be of sufficient length to reach the splice location for splicing by BellSouth. ComSouth must contact BellSouth for authorization and instruction prior to placing any entrance facility cable in an entrance manhole or cable vault. ACCESS Integrated ComSouth is responsible for the maintenance of the entrance facilities. Nonrecurring charges for cable installation will be assessed on a per cable basis as set forth in Exhibit B upon receipt of ACCESS IntegratedComSouth’s BFFO. Recurring charges for the cable support structure will be billed at the rates set forth in Exhibit B.

Appears in 1 contract

Samples: clec.att.com

Time is Money Join Law Insider Premium to draft better contracts faster.