Hydrogen analyser. 4.3.1.1. The atmosphere within the chamber is monitored using a hydrogen analyser (electrochemical detector type) or a chromatograph with thermal conductivity detection. Sample gas shall be drawn from the mid-point of one side-wall or roof of the chamber and any bypass flow shall be returned to the enclosure, preferably to a point immediately downstream of the mixing fan.
Appears in 9 contracts
Hydrogen analyser. 4.3.1.1. The atmosphere within the chamber is monitored using a hydrogen analyser (electrochemical detector type) or a chromatograph with thermal conductivity detection. Sample gas shall must be drawn from the mid-point of one side-wall or roof of the chamber and any bypass flow shall must be returned to the enclosure, preferably to a point immediately downstream of the mixing fan.
Appears in 3 contracts
Samples: unece.org, digitallibrary.un.org, www.unece.org
Hydrogen analyser. 4.3.1.14.2.1.1. The atmosphere within the chamber is monitored using a hydrogen analyser (electrochemical detector type) or a chromatograph with thermal conductivity detection. Sample gas shall be drawn from the mid-point of one side-wall or roof of the chamber and any bypass flow shall be returned to the enclosure, preferably to a point immediately downstream of the mixing fan.
Appears in 2 contracts
Samples: www.unece.org, www.myanmarstandards.org.mm