Disturbance Analysis Data Exchange. The Parties will cooperate with one another and the NYISO in the analysis of disturbances to either the Large Generating Facility or the New York State Transmission System by gathering and providing access to any information relating to any disturbance, including information from disturbance recording equipment, protective relay targets, breaker operations and sequence of events records, and any disturbance information required by Good Utility Practice.
Disturbance Analysis Data Exchange. The Parties will cooperate with one another in the analysis of disturbances to either the Large Generating Facility or the CAISO Controlled Grid by gathering and providing access to any information relating to any disturbance, including information from oscillography, protective relay targets, breaker operations and sequence of events records, and any disturbance information required by Good Utility Practice.
Disturbance Analysis Data Exchange. The Parties will cooperate with one another in the analysis of disturbances to either the Large Generating Facility or the New England Transmission System by gathering and providing access to any information relating to any disturbance, including information from oscillography, protective relay targets, breaker operations and sequence of events records, and any disturbance information required by the ISO New England Operating Documents, Applicable Reliability Standards, or successor documents.
Disturbance Analysis Data Exchange. The Parties will cooperate with one another in the analysis of disturbances to either the Generating Facility or the Transmission System
Disturbance Analysis Data Exchange. 5245 Article 10. Maintenance 5245 10.1 DISTRIBUTION PROVIDER OBLIGATIONS 5245 10.2 INTERCONNECTION CUSTOMER OBLIGATIONS 5345 10.3 COORDINATION 5345 10.4 SECONDARY SYSTEMS 5345 10.5 OPERATING AND MAINTENANCE EXPENSES 5345 Article 11. Performance Obligation 5345 11.1 INTERCONNECTION CUSTOMER INTERCONNECTION FACILITIES 5345 11.2 DISTRIBUTION PROVIDER'S INTERCONNECTION FACILITIES 5346
11.3 NETWORK UPGRADES AND DISTRIBUTION UPGRADES 5346
Disturbance Analysis Data Exchange. The Parties will cooperate with one another and the NYISO in the analysis of disturbances to either the Mainesburg Substation, the PJM Transmission System, the Watercure Line, or the New York State Transmission System by gathering and providing access to any information relating to any disturbance, including information from disturbance recording 41 SERVICE AGREEMENT NO. 2232 equipment, protective relay targets, breaker operations and sequence of events records, and any disturbance information required by Good Utility Practice.
Disturbance Analysis Data Exchange. The Parties will cooperate with one another in the analysis of disturbances to either the Large Generating Facility or Transmission Provider’s Transmission System by gathering and providing access to any information relating to any disturbance, including information from oscillography, protective relay targets, breaker operations and sequence of events records, and any disturbance information required by Good Utility Practice. Arizona Public Service Company APS Contract No. 52023 LGIA (Large Generator Interconnection Agreement)
Disturbance Analysis Data Exchange. The Parties will cooperate with one another in the analysis of disturbances to either the Large Generating Facility or the New England Transmission
Disturbance Analysis Data Exchange. The Parties will cooperate with one another in the analysis of disturbances to either the Transmission Interconnected Generating Facility or JEA's Transmission System by gathering and providing access to any information relating to any disturbance, including information from oscillography, Phasor Measurement Unit or similar device, protective relay targets, breaker operations and sequence of events records, and any disturbance information required by Good Utility Practice.
Disturbance Analysis Data Exchange. The provision refers just to the “Transmission Systems,” similar to the CAISO LGIA, since the term “Transmission Provider” in the APS LGIA is not used in this Agreement.