INTERIOR DOOR ASSEMBLY a. Doors shall be WEYERHAEUSER Architectural Doors, Solid Core Wood Veneer Door with matching edges, 3'-0" x 8'-10" x 1-3/4" (U.N.O.). Doors shall conform to A.W.I. standards and carry a lifetime guarantee. Doors shall be pre-finished with Weyerhaeuser Plain Sliced Cherry with Standard Finish 28-95 "Toast". All applicable listing labels shall be provided and securely fastened to doors.
AutoNDA by SimpleDocs

Related to INTERIOR DOOR ASSEMBLY

  • Interior (a) Ceilings, sidewalls and bulkhead panels shall be clean and free of cracks and stains;

  • ASBESTOS CONTAINING BUILDING MATERIALS Please be advised that an asbestos survey may have been performed at the Property. If provided, please review the information that identifies the locations of known asbestos containing material or presumed asbestos containing material. All personnel and appropriate subcontractors should be notified of the presence of these materials, and informed not to disturb these materials. Any activity that involves the disturbance or removal of these materials must be done by an appropriately trained individual/contractor.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Installation Tenant may install and use Tenant's Lines and make connections and disconnections at the terminal blocks as described above, provided Tenant shall: (i) obtain Landlord's prior written approval of all aspects thereof, (ii) use an experienced and qualified contractor designated or approved in writing in advance by Landlord (whom Landlord may require to enter an access and indemnity agreement on Landlord's then standard form of agreement therefor), (iii) comply with such inside wire standards as Landlord may adopt from time to time, and all other provisions of this Lease, including Paragraph 8 respecting alterations, and the Building rules respecting access to the wire closets, (iv) not install Lines in the same sleeve, chaseway or other enclosure in close proximity with electrical wire, and not install PVC-coated Lines under any circumstances, (v) thoroughly test any riser Lines to which Tenant intends to connect any Lines to ensure that such riser Lines are available and are not then connected to or used for telephone, data transmission or any other purpose by any other party (whether or not Landlord has previously approved such connections), and not connect to any such unavailable or connected riser Lines, and (vi) not connect any equipment to the Lines which may create an electromagnetic field exceeding the normal insulation ratings of ordinary twisted pair riser cable or cause radiation higher than normal background radiation, unless the Lines therefor (including riser Lines) are appropriately insulated to prevent such excessive electromagnetic fields or radiation (and such insulation shall not be provided by the use of additional unused twisted pair Lines). As a condition to permitting installation of new Lines, Landlord may require that Tenant remove any existing Lines located in or serving the Premises.

  • Demolition Landlord shall have the right to terminate this Lease if Landlord proposes or is required, for any reason, to remodel, remove, or demolish the Building or any substantial portion thereof. Such cancellation shall be exercised by Landlord by the service of not less than ninety (90) days' written notice of such termination. Such notice shall set forth the date upon which the termination will be effective. No money or other consideration shall be payable by Landlord to Tenant for Landlord's exercise of this right, and the right is hereby reserved to Landlord and all purchasers, successors, assigns, transferees, and ground tenants of Landlord, as the case may be, and is in addition to all other rights of Landlord. Tenant has read the foregoing and understands that Landlord has a right to terminate this Lease as provided above.

  • Excavation If any excavation shall be made upon land adjacent to or under the Building, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation license to enter the Premises for the purpose of performing such work as said person shall deem reasonably necessary to preserve and protect the Building from injury or damage and to support the same by proper foundations, without any claim for damages or liability against Landlord (except in the case of Landlord Parties’ willful misconduct or gross negligence) and without reducing or otherwise affecting Tenant’s obligations under this Lease. Any such work must be conducted in a manner that minimizes disruption and inconvenience to Tenant.

  • Painting (a) Interior wall surfaces of gypsum board shall receive two (2) coats of flat latex paint, colors to be selected by Tenant from Landlord's samples.

  • Spares Boeing will revise, as applicable, the customized Recommended Spares Parts List (RSPL) and Illustrated Parts Catalog (IPC).

  • Building Systems The term “Building Systems” means all systems serving the Building in general, including, but not limited to, the fire/life safety, electrical, plumbing, HVAC, including all components thereof and related equipment, but excluding any equipment that is separately installed by or on behalf of Tenant and any distribution systems or equipment existing within the Premises.

  • Cleaning 4.6.1 To keep the Property clean, tidy and free from rubbish;