Labrador - Island Overland HVdc Transmission Sample Clauses

Labrador - Island Overland HVdc Transmission.  An HVdc overhead transmission line, ±350 kV bi-pole, to connect the Muskrat Falls Converter Station to the Labrador Transition Compound at the Strait of Belle Isle and then to connect the Northern Peninsula Transition Compound at the Strait of Belle Isle to the Soldiers Pond Converter Station.  Transmission line to carry both poles (single conductor per pole) and one OPGW. The Labrador section is to carry two electrode conductors from the Muskrat Falls Converter Station to Xxxxxxx Xxxxx (xxx 0000 Xxxxxxxxx Xxxx - Xxxxxxxx).  The HVdc transmission line is to have a designed nominal power capacity of 900 MW; however, given the mono-polar operation criteria, each pole is to have a nominal rating of 450 MW with 100% overload capacity for ten minutes and 50% overload capacity for continuous operation.  Counterpoise installed from station-to-station.  Towers are to be galvanized lattice steel, with self-supported angles and dead ends, and guyed suspension towers.  50 year Reliability Level Return Period of loads, with respect to Nalcor Energy operating experience and LCP specific modeling and test programs.
AutoNDA by SimpleDocs

Related to Labrador - Island Overland HVdc Transmission

  • Nyiso and Connecting Transmission Owner Authority General.‌‌ NYISO or Connecting Transmission Owner may take whatever actions with regard to the New York State Transmission System or the Connecting Transmission Owner’s Attachment Facilities it deems necessary during an Emergency State in order to (i) preserve public health and safety, (ii) preserve the reliability of the New York State Transmission System or the Connecting Transmission Owner’s Attachment Facilities, (iii) limit or prevent damage, and (iv) expedite restoration of service. NYISO and Connecting Transmission Owner shall use Reasonable Efforts to minimize the effect of such actions or inactions on the Large Generating Facility or the Developer’s Attachment Facilities. NYISO or Connecting Transmission Owner may, on the basis of technical considerations, require the Large Generating Facility to mitigate an Emergency State by taking actions necessary and limited in scope to remedy the Emergency State, including, but not limited to, directing Developer to shut-down, start-up, increase or decrease the real or reactive power output of the Large Generating Facility; implementing a reduction or disconnection pursuant to Article 13.4.2; directing the Developer to assist with blackstart (if available) or restoration efforts; or altering the outage schedules of the Large Generating Facility and the Developer’s Attachment Facilities. Developer shall comply with all of the NYISO and Connecting Transmission Owner’s operating instructions concerning Large Generating Facility real power and reactive power output within the manufacturer’s design limitations of the Large Generating Facility’s equipment that is in service and physically available for operation at the time, in compliance with Applicable Laws and Regulations.

  • Transmission Control In-transit: We make HTTPS encryption (also referred to as SSL or TLS) available on every one of its login interfaces and for free on every customer site hosted on the HubSpot products. Our HTTPS implementation uses industry standard algorithms and certificates. At-rest: We store user passwords following policies that follow industry standard practices for security. We have implemented technologies to ensure that stored data is encrypted at rest.

  • Regional and Local Transmission The prices quoted in Exhibit A do not include current and future charges for distribution service costs collected by the Local Distributor under its distribution service tariff or local transmission costs as may be imposed by the regional power pool, ISO-NE, or individual electric utilities that have FERC transmission tariffs. Its Competitive Supplier understands that these costs will be collected by the Local Distributor. If, in the future, Competitive Supplier becomes responsible for such distribution or transmission costs, Competitive Supplier shall be entitled to collect such costs from Participating Consumers to the extent permitted by any Governmental Rules. These costs are “pass through” costs as determined by the appropriate regulatory agencies.

  • NYISO and Connecting Transmission Owner Obligations Connecting Transmission Owner and NYISO shall cause the New York State Transmission System and the Connecting Transmission Owner’s Attachment Facilities to be operated, maintained and controlled in a safe and reliable manner in accordance with this Agreement and the NYISO Tariffs. Connecting Transmission Owner and NYISO may provide operating instructions to Developer consistent with this Agreement, NYISO procedures and Connecting Transmission Owner’s operating protocols and procedures as they may change from time to time. Connecting Transmission Owner and NYISO will consider changes to their respective operating protocols and procedures proposed by Developer.

  • Data Transmission Control Except as necessary for the provision of the Cloud Services in accordance with the Agreement, Personal Data must not be read, copied, modified or removed without authorization during transfer. Where data carriers are physically transported, adequate measures are implemented at SAP to provide the agreed-upon service levels (for example, encryption and lead-lined containers). Measures: • Personal Data in transfer over SAP internal networks is protected according to SAP Security Policy. • When data is transferred between SAP and its customers, the protection measures for the transferred Personal Data are mutually agreed upon and made part of the relevant agreement. This applies to both physical and network based data transfer. In any case, the Customer assumes responsibility for any data transfer once it is outside of SAP-controlled systems (e.g. data being transmitted outside the firewall of the SAP Data Center).

  • Developer and Connecting Transmission Owner Notice Developer and Connecting Transmission Owner shall each notify the other Party, first orally and then in writing, of the release of any Hazardous Substances, any asbestos or lead abatement activities, or any type of remediation activities related to the Large Generating Facility or the Attachment Facilities, each of which may reasonably be expected to affect the other Party. The notifying Party shall: (i) provide the notice as soon as practicable, provided such Party makes a good faith effort to provide the notice no later than twenty-four hours after such Party becomes aware of the occurrence; and (ii) promptly furnish to the other Party copies of any publicly available reports filed with any Governmental Authorities addressing such events.

  • FLOODPLAIN MANAGEMENT AND WETLAND PROTECTION Executive Order 11988, Floodplain Management, May 24, 1977 (42 FR 26951), 3 C.F.R., 1977 Comp., p. 117, as interpreted in HUD regulations at 24 C.F.R. Part 55, particularly Section 2(a) of the Order (For an explanation of the relationship between the decision- making process in 24 C.F.R. Part 55 and this part, see § 55.10.); and Executive Order 11990, Protection of Wetlands, May 24, 1977 (42 FR 26961), 3 C.F.R., 1977 Comp., p. 121 particularly Sections 2 and 5. COASTAL ZONE MANAGEMENT The Coastal Zone Management Act of 1972 (16 U.S.C. § 1451, et seq.), as amended, particularly sections 307(c) and (d) (16 U.S.C. § 1456(c) and (d)).

  • COMMUNICATIONS BETWEEN THE PARTIES A copy of all communications relating to the subject matter of this Agreement between the Issuer and any Paying Agent (other than the Agent) shall be sent to the Agent.

  • Connecting Transmission Owner’s Attachment Facilities Construction The Connecting Transmission Owner’s Attachment Facilities shall be designed and constructed in accordance with Good Utility Practice. Upon request, within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Connecting Transmission Owner and Developer agree on another mutually acceptable deadline, the Connecting Transmission Owner shall deliver to the Developer “as-built” drawings, relay diagrams, information and documents for the Connecting Transmission Owner’s Attachment Facilities set forth in Appendix A. The Connecting Transmission Owner [shall/shall not] transfer operational control of the Connecting Transmission Owner’s Attachment Facilities and Stand Alone System Upgrade Facilities to the NYISO upon completion of such facilities.

  • Association Communications The Association will have the right to place official notices, circulars and other professional materials in teachers' mailboxes.

Time is Money Join Law Insider Premium to draft better contracts faster.