Liquefied/Converted Methane Sample Clauses

Liquefied/Converted Methane. LNG Gas" means methane liquefied into liquid natural gas ("LNG") or converted into synthetic crude or synthetic hydrocarbon products. As to any methane which Seller, on behalf of itself or Seller Affiliate, elects to liquefy or convert into synthetic hydrocarbons, such methane shall not be Committed Gas and title to the LNG's or synthetic hydrocarbons shall not pass to Purchaser hereunder, but shall remain at all times with Seller or Seller Affiliate. Seller shall give Purchaser at least one (1) year advance notice of any election under this Section. Seller may, in conjunction with its election, request that Purchaser market LNG Gas on behalf of Seller or Seller Affiliate, provided that Seller and Purchaser agree on the terms of such a marketing arrangement.
AutoNDA by SimpleDocs

Related to Liquefied/Converted Methane

  • Unbundled Sub-Loop Feeder 2.8.4.1 Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and cross-box (or other access point) that serves an end user location. 2.8.4.2 USLF utilized for voice traffic can be configured as 2-wire voice (USLF-2W/V) or 4-wire voice (USLF-4W/V). 2.8.4.3 USLF utilized for digital traffic can be configured as 2-wire ISDN (USLF-2W/I); 2-wire Copper (USLF-2W/C); 4-wire Copper (USLF-4W/C); 4-wire DS0 level loop (USLF-4W/D0); or 4-wire DS1 and ISDN (USLF-4W/DI). 2.8.4.4 USLF will provide access to both the equipment and the features in the BellSouth central office and BellSouth cross box necessary to provide a 2W or 4W communications pathway from the BellSouth central office to the BellSouth cross- box. This element will allow for the connection of Lightyear’s loop distribution elements onto BellSouth's feeder system.

  • Reactive Power and Primary Frequency Response 9.6.1 Power Factor Design Criteria

  • Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)

  • Dark Fiber Transport Dark Fiber Transport is defined as Dedicated Transport that consists of unactivated optical interoffice transmission facilities without attached signal regeneration, multiplexing, aggregation or other electronics. Except as set forth in Section 6.9.1 below, BellSouth shall not be required to provide access to Dark Fiber Transport Entrance Facilities pursuant to this Agreement.

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.

  • Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • Tandem Transit Traffic ‌ 12.1 As used in this Section, Tandem Transit Traffic is Telephone Exchange Service traffic that originates on Onvoy's network, and is transported through Frontier’s Tandem to the subtending End Office or its equivalent of another carrier (CLEC, ILEC other than Frontier, Commercial Mobile Radio Service (CMRS) carrier, or other LEC (“Other Carrier”). Neither the originating nor terminating customer is a Customer of Frontier. Subtending End Offices shall be determined in accordance with and as identified in the Local Exchange Routing Guide (LERG). For the avoidance of any doubt, under no circumstances shall Frontier be required to transit traffic through a Frontier Tandem to a Central Office that the LERG does not identify as subtending that particular Frontier Tandem. Switched Exchange Access Service traffic is not Tandem Transit Traffic. 12.2 Tandem Transit Traffic Service provides Onvoy with the transport of Tandem Transit Traffic as provided below. 12.3 Tandem Transit Traffic may be routed over the Interconnection Trunks described in Sections 2 through 6 of this Attachment. Onvoy shall deliver each Tandem Transit Traffic call to Frontier’s Tandem with CCS and the appropriate Transactional Capabilities Application Part (“TCAP”) message to facilitate full interoperability of CLASS Features and billing functions. 12.4 Onvoy may use Tandem Transit Traffic Service only for traffic that originates on Onvoy’s network and only to send traffic to an Other Carrier with whom Onvoy has a reciprocal traffic exchange arrangement (either via written agreement or mutual tariffs) that provides for the Other Carrier, to terminate or complete traffic originated by Onvoy and to bill Onvoy, and not to bill Frontier, for such traffic. Onvoy agrees not to use Frontier’s Tandem Transit Traffic Service to send traffic to an Other Carrier with whom Onvoy does not have such a reciprocal traffic exchange arrangement or to send traffic that does not originate on Onvoy’s network. 12.5 Onvoy shall pay Frontier for Tandem Transit Traffic Service at the rates specified in the Pricing Attachment. Frontier will not be liable for compensation to any Other Carrier for any traffic that is transported through Frontier’s Tandem and Frontier reserves the right to assess to Onvoy any additional charges or costs any Other Carrier imposes or levies on Frontier for the delivery or termination of such traffic, including any Switched Exchange Access Service charges. If Frontier is billed by any Other Carrier for any traffic originated by Onvoy, Frontier may provide notice to Onvoy of such billing. Upon receipt of such notice, Onvoy shall immediately stop using Frontier’s Tandem Transit Traffic Service to send any traffic to such Other Carrier until it has provided to Frontier certification that the Other Carrier has removed such billed charges from its bill to Frontier and that the Other Carrier will not bill Frontier for any traffic originated by Onvoy. Such certification must be signed by an authorized officer or agent of the Other Carrier and must be in a form acceptable to Frontier. 12.6 If Onvoy uses Tandem Transit Traffic Service for traffic volumes that exceed the Centum Call Seconds (Hundred Call Seconds) busy hour equivalent of 200,000 combined minutes of use per month (a DS1 equivalent) to the subtending End Office of a particular Other Carrier for any month (the “Threshold Level”). Onvoy shall use good faith efforts to establish direct interconnection with such Other Carrier and reduce such traffic volumes below the Threshold Level. If Frontier believes that Xxxxx has not exercised good faith efforts promptly to obtain such direct interconnection, either Party may use the Dispute Resolution processes of this Agreement. 12.7 If Onvoy fails to comply with Section 12 of this Attachment, such failure shall be a material breach of a material provision of this Agreement and Frontier may exercise any and all remedies under this Agreement and Applicable Law for such breach. 12.8 If or when a third party carrier plans to subtend an Onvoy switch, then Onvoy shall provide written notice to Frontier at least ninety (90) days before such subtending service arrangement becomes effective so that Frontier may negotiate and establish direct interconnection with such third party carrier. Upon written request from Frontier, Onvoy shall offer to Frontier a service arrangement equivalent to or the same as Tandem Transit Traffic Service provided by Frontier to Onvoy as defined in this Section such that Frontier may terminate calls to a Central Office or its equivalent of a CLEC, ILEC other than Frontier, CMRS carrier, or other LEC, that subtends an Onvoy Central Office or its equivalent (“Reciprocal Tandem Transit Service”). Onvoy shall offer such Reciprocal Transit Service arrangements under terms and conditions of an amendment to this Agreement or a separate agreement no less favorable than those provided in this Section. 12.9 Neither Party shall take any actions to prevent the other Party from entering into a direct and reciprocal traffic exchange arrangement with any carrier to which it originates, or from which it terminates, traffic.

  • Unbundled Copper Loops (UCL) 2.4.1 BellSouth shall make available Unbundled Copper Loops (UCLs). The UCL is a copper twisted pair Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters) and is not intended to support any particular telecommunications service. The UCL will be offered in two types – Designed and Non-Designed.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!