Liquid Level Gauging Devices Sample Clauses

Liquid Level Gauging Devices. Each LNG tank of the LNG Vessel shall be equipped with primary and secondary liquid level gauging devices as per Paragraph 7(b) of this Annex I. The measurement accuracy of the primary gauging devices shall be plus or minus seven point five (± 7.5) millimeters and the secondary liquid level gauging devices shall be plus or minus ten (± 10) millimeters. The liquid level in each LNG tank shall be logged or printed.
AutoNDA by SimpleDocs
Liquid Level Gauging Devices. (a) Each LNG tank of each LNG Ship shall be equipped with a main and an auxiliary liquid level gauging device.
Liquid Level Gauging Devices. Each LNG tank of each LNG Vessel shall be equipped with a main and an auxiliary liquid level gauging device. The measurement uncertainty of the main liquid level gauging devices shall be +/-
Liquid Level Gauging Devices. (a) The condition of the tank at the time of the custody transfer shall be as described in clause 5.6 of ISO 13398. (b) Each LNG tank of each LNG Vessel shall be equipped with a main and an auxiliary liquid level gauging device. Preferable order is microwave, electrical capacitance and float. For each kind, its characteristics, tolerances, installation, operation and checking will be based on the following standards: (i) Microwaves gauges. ISO 13689. Refrigerated light hydrocarbon fluids – Measurement of liquid levels in tank containing liquefied gases – Microwave gauges. (ii) Electrical capacitance gauges. ISO 8309. Refrigerated light hydrocarbon fluids – Measurement of liquid levels in tank containing liquefied gases Electrical capacitance gauge. (iii) Float type level gauges. ISO 10574. Refrigerated light hydrocarbon fluids – Measurement of liquid levels in tank containing liquefied gases – Float type level gauges.

Related to Liquid Level Gauging Devices

  • Market disruption; non-availability 3.6.1 If and whenever, at any time prior to the commencement of any Interest Period:

  • Cost of Metering The Issuer shall not be obligated to pay any costs associated with the routine metering duties set forth in this Section 2, including the costs of installing, replacing and maintaining meters, nor shall the Issuer be entitled to any credit against the Servicing Fee for any cost savings realized by the Servicer as a result of new metering and/or billing technologies.

  • Measurement Should the State terminate this contract as herein provided, no fees other than fees due and payable at the time of termination shall thereafter be paid to the Engineer. In determining the value of the work performed by the Engineer prior to termination, the State shall be the sole judge. Compensation for work at termination will be based on a percentage of the work completed at that time. Should the State terminate this contract under paragraph (4) or (5) above, the Engineer shall not incur costs during the thirty-day notice period in excess of the amount incurred during the preceding thirty days.

  • Temperature Where low temperature and/or self-service cases are used for any of such merchandise coming under the jurisdiction of the Union, such cases shall be served only by employees covered by this Agreement.

  • Floor Load Tenant shall not place a load upon any floor of the Premises that exceeds 50 pounds per square foot “live load”. Landlord reserves the right to reasonably designate the position of all Equipment which Tenant wishes to place within the Premises, and to place limitations on the weight thereof.

  • Floor Loading Floor loading capacity shall be within building design capacity. Tenant may exceed floor loading capacity with Landlord’s consent, at Landlord’s sole discretion and must, at Tenant’s sole cost and expense, reinforce the floor as required for such excess loading.

  • Measurement Period (b) In this Agreement, unless the contrary intention appears, a reference to:

  • Delivery Points ‌ Project water made available to the Agency pursuant to Article 6 shall be delivered to the Agency by the State at the delivery structures established in accordance with Article 10.

  • Delivery Pressure Xxxxxx agrees to use due care and diligence to furnish gas hereunder at such uniform pressure as Seller may elect up to, but not exceeding 20 pounds per square inch gauge, and not less than 5 pounds per square inch gauge, at the "Point of Delivery". Buyer shall be responsible for the installation and operation of adequate safety equipment downstream of the Point of Delivery so as to relieve or control pressure variations within the limits described above that may, for any reason through malfunction of Seller's equipment or otherwise, occur on Buyer's side of the "Delivery Point".

Time is Money Join Law Insider Premium to draft better contracts faster.