Maintenance and Operation Costs of the Enterprise Sample Clauses

Maintenance and Operation Costs of the Enterprise. In order to carry out and effectuate the pledge and lien contained herein, the District agrees and covenants to pay all Maintenance and Operation Costs of the Enterprise (including amounts reasonably required to be set aside in contingency reserves for Maintenance and Operation Costs of the Enterprise, the payment of which is not then immediately required) from the Revenue Fund as they become due and payable.
AutoNDA by SimpleDocs

Related to Maintenance and Operation Costs of the Enterprise

  • Maintenance and Operation Member-Generator agrees to maintain their system and facilities in accordance with applicable manufacturer's recommended maintenance schedule and standard prudent engineering practices. Member-Generator covenants and agrees to operate their system, facilities and equipment so as to minimize the likelihood for a malfunction or other disturbance, damaging or otherwise affecting or impairing Cooperative’s electrical system. Member-Generator shall comply with all applicable laws, regulations, zoning, building codes, safety rules and other environmental regulations or restrictions applicable to the design, installation, operation and maintenance of the Member-Generator's System. Member-Generator must, at least once every year, conduct a test to confirm that Member-Generator’s System automatically ceases to energize the output (interconnection equipment output voltage goes to zero) within two (2) seconds of being disconnected from Cooperative’s electrical system. Disconnecting the Member-Generator’s System from Cooperative’s electrical system at the visible disconnect switch and measuring the time required for the unit to cease to energize the output shall satisfy this test. Member-Generator shall maintain a record of the results of these tests and, upon request by Cooperative, shall provide a copy of the test results to Cooperative. If Member-Generator is unable to provide a copy of the test results upon request, Cooperative shall notify Member- Generator by mail that Member-Generator has thirty (30) days from the date Member-Generator receives the request to provide Cooperative with the results of a test. If Member-Generator does not provide Cooperative with the test results within the thirty (30) day time period or if the test results provided to Cooperative show that Member-Generator’s net metering unit is not functioning correctly, Cooperative may immediately disconnect Member-Generator’s System from Cooperative’s electrical system. If Member-Generator’s equipment ever fails this test, Member-Generator shall immediately disconnect Member-Generator’s System from Cooperative's electrical system. Member-Generator’s System shall not be reconnected to Cooperative's electrical system by the Member-Generator until Member-Generator’s System is repaired and operating in a normal and safe manner. Cooperative shall have the right to have a representative present and informed when any such tests are conducted. Cooperative does not warrant the testing procedures or results by the presence of its representative. Member-Generator is responsible for protecting their equipment from transient high voltage spikes caused by lightning and/or transient low voltage conditions caused by faults or short circuits, and from any other causes or events. Therefore, Cooperative shall not be responsible for damage to Member-Generator’s equipment allegedly caused by transient high voltage spikes caused by lightning and/or transient low voltage conditions caused by faults or short circuits or other causes or events. Member-Generator agrees to notify Cooperative no less than thirty (30) days prior to modification of the components or design of the Member-Generator’s System that in any way may degrade or significantly alter the System’s output characteristics. Member-Generator acknowledges that any such modifications will require submission of a new Application and Agreement to Cooperative.

  • Operating and Maintenance Expenses Subject to the provisions herein addressing the use of facilities by others, and except for operations and maintenance expenses associated with modifications made for providing interconnection or transmission service to a third party and such third party pays for such expenses, the Interconnection Customer shall be responsible for all reasonable expenses including overheads, associated with: (1) owning, operating, maintaining, repairing, and replacing the Interconnection Customer’s Interconnection Facilities; and (2) operation, maintenance, repair and replacement of the Participating TO’s Interconnection Facilities.

  • Assistance expenses The Parties shall waive all claims on each other for the reimbursement of expenses incurred in accordance with this Chapter, except, as appropriate, for expenses related to experts and witnesses and to interpreters and translators who are not public officials.

  • Operations and Maintenance Pursuant to Section 10.5 of this Agreement, Developer shall pay the reasonable expenses (including overheads) for the operation, maintenance, repair and replacement of Transmission Owner’s Attachment Facilities and incremental operating and maintenance expenses incurred in association with System Upgrade Facilities, if and to the extent provided for under Attachment S. For Transmission Owner’s Attachment Facilities, such expenses are calculated as follows:

  • General Expenses You authorize the Manager to charge your account with your Underwriting Percentage of all expenses of a general nature incurred by the Manager and Co-Managers under the applicable AAU in connection with the Offering, including the negotiation and preparation thereof, or in connection with the purchase, carrying, marketing and sale of any securities under the applicable AAU and any Intersyndicate Agreement, including, without limitation, legal fees and expenses, transfer taxes, costs associated with approval of the Offering by the NASD and the costs of currency transactions (including forward and hedging currency transactions) entered into to facilitate settlement of the purchase of Securities permitted under Section 3.1 hereof.

  • Lodging and Meal Expenses 1. Employees in travel status in the performance of their duties shall be entitled to expenses of necessary lodging and/or meals as provided for in Section 40 of the Manual of Financial Procedures, Travel and Expense Reimbursement Policy. Nothing contained in this Article shall be deemed to alter the present State policy prohibiting reimbursement for noon meals unless the meal is part of an organized meeting or program or overnight travel.

  • Operating Costs The Assuming Institution agrees, during its period of use of any Leased Data Management Equipment, to pay to the Receiver or to appropriate third parties at the direction of the Receiver all operating costs with respect thereto and to comply with all relevant terms of any existing Leased Data Management Equipment leases entered into by the Failed Bank, including without limitation the timely payment of all rent, taxes, fees, charges, maintenance, utilities, insurance and assessments.

  • FUNERAL EXPENSES The City shall expend a sum of money not to exceed $30,000 for funeral expenses to the heirs of any Unit member who dies while on active duty from injuries incurred while performing his/her job or who dies as a direct cause of such injuries. This amount includes any amount already available for this purpose in accordance with California State Labor Code Section 4701.

  • Operating and Maintenance Costs The Participating Generator shall be responsible for all its costs incurred in connection with operating and maintaining the Generating Units identified in Schedule 1 for the purpose of meeting its obligations under this Agreement.

  • Maintenance and Repair – Line Sharing 3.6.1 C.M. shall have access for repair and maintenance purposes to any Loop for which it has access to the High Frequency Spectrum. If C.M. is using a BellSouth owned splitter, C.M. may access the Loop at the point where the combined voice and data signal exits the central office splitter via a bantam test jack. If C.M. provides its own splitter, it may test from the collocation space or the Termination Point.

Time is Money Join Law Insider Premium to draft better contracts faster.