Materials Testing. All installation, wiring, and cabling requirements identified in the Purchase Order/ SOW must be satisfied. All materials must be tested, functional and certified, based on ANSI/TIA/EIA installation requirements and approved by the Purchaser and/or Purchaser’s on- site coordinator prior to acceptance for payment. Minimum testing of copper cable is to include Wire Map, continuity, NEXT and attenuation in accordance with the most current ANSI/TIA/EIA-568 standard. Minimum testing for fiber cable is to include testing the attenuation and polarity of the installed cable with an optical loss test set (OLTS) and the installed condition of the fiber cabling with an optical time domain reflectometer (OTDR). Multi-mode and single-node backbone links shall be tested in accordance with the appropriate current ANSI/TIA and industry standards.
Appears in 3 contracts
Samples: Master Contract, Master Contract, Master Contract
Materials Testing. All installation, wiring, and cabling requirements identified in the Purchase Order/ SOW must be satisfied. All materials must be tested, functional and certified, based on ANSI/TIA/EIA installation requirements and approved by the Purchaser and/or Purchaser’s on- on-site coordinator prior to acceptance for payment. Minimum testing of copper cable is to include Wire Map, continuity, NEXT and attenuation in accordance with the most current ANSI/TIA/EIA-568 standard. Minimum testing for fiber cable is to include testing the attenuation and polarity of the installed cable with an optical loss test set (OLTS) and the installed condition of the fiber cabling with an optical time domain reflectometer (OTDR). Multi-mode and single-node backbone links shall be tested in accordance with the appropriate current ANSI/TIA and industry standards.
Appears in 2 contracts
Samples: Master Contract, Master Contract
Materials Testing. All installation, wiring, and cabling requirements identified in the Purchase Order/ SOW must be satisfied. All materials must be tested, functional and certified, based on ANSI/TIA/EIA installation requirements and approved by the Purchaser and/or Purchaser’s on- site on‐site coordinator prior to acceptance for payment. Minimum testing of copper cable is to include Wire Map, continuity, NEXT and attenuation in accordance with the most current ANSI/TIA/EIA-568 EIA‐568 standard. Minimum testing for fiber cable is to include testing the attenuation and polarity of the installed cable with an optical loss test set (OLTS) and the installed condition of the fiber cabling with an optical time domain reflectometer (OTDR). Multi-mode Multi‐mode and single-node single‐node backbone links shall be tested in accordance with the appropriate current ANSI/TIA and industry standards.
Appears in 1 contract
Samples: Master Contract