Common use of Measurement Accuracy Verification Clause in Contracts

Measurement Accuracy Verification. (a) Each Party shall verify the accuracy of all Measurement Facilities or other equipment or facilities used in measuring or checking the measurement of volumes of Fresh Water or Produced Water under this Agreement owned by such Party no less frequently than twice per year, unless a special test is requested pursuant to Section 10.4. (b) If, during any test of such Measuring Facilities, an adjustment or calibration error is found which results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for the period redetermined in accordance with the provisions of Section 10.5. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be made over a period extending over the last one half of the time elapsed since the date of the prior test revealing the two percent (2%) error. (c) If, during any test of any Measurement Facilities, an adjustment or calibration error is found which results in an incremental adjustment to the calculated hourly flow rate which does not exceed two percent (2%) of the adjusted flow rate, all prior recordings and electronic flow computer data shall be considered to be accurate for volume determination purpose.

Appears in 5 contracts

Samples: Water Services Agreement, Water Services Agreement (Rice Midstream Partners LP), Water Services Agreement (Rice Energy Inc.)

AutoNDA by SimpleDocs

Measurement Accuracy Verification. (a) Each Party Gatherer shall verify the accuracy of all Measurement Facilities or other equipment or facilities used calibrate meters as often as required, as determined by Gatherer in measuring or checking the measurement of volumes of Fresh Water or Produced Water under this Agreement owned by such Party no less frequently than twice accordance with standard industry practices and applicable regulatory standards to reasonably assure accurate measurement, but at least once per year, unless Month for any Receipt Point with a special test is requested pursuant to Section 10.4LACT meter unit. (b) If, during any test of such Measuring the Measurement Facilities, an adjustment or calibration meter proving error is found which results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) 0.25% of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which period is either known definitely or agreed to by the PartiesShipper and Gatherer) and the total flow for the period redetermined in accordance with the provisions of Section 10.5. If the period of error condition cannot be determined or agreed upon between the PartiesShipper and Gatherer, such correction shall be made over a period extending over the last one half of the time elapsed since the date of the prior test revealing the two percent (2%) 0.25% error. (c) If, during any test of any Measurement Facilities, an adjustment or calibration meter proving error is found which results in an incremental adjustment to the calculated hourly flow rate which does not exceed two percent (2%) 0.25% of the adjusted flow rate, all prior recordings and electronic flow computer data shall be considered to be accurate for volume quantity determination purpose.

Appears in 2 contracts

Samples: Crude Oil Gathering and Storage Agreement (Oasis Midstream Partners LP), Crude Oil Gathering and Storage Agreement (Oasis Midstream Partners LP)

Measurement Accuracy Verification. (a) Each Party Gatherer shall verify the accuracy of all Measurement Facilities or other equipment or facilities used calibrate meters as often as required, as determined by Gatherer in measuring or checking the measurement of volumes of Fresh Water or Produced Water under this Agreement owned by such Party no less frequently than twice accordance with standard industry practices and applicable regulatory standards to reasonably assure accurate measurement, but at least once per year, unless Month for any Receipt Point with a special test is requested pursuant to Section 10.4LACT meter unit. (b) If, during any test of such Measuring the Measurement Facilities, an adjustment or calibration meter proving error is found which results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) [***]% of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the PartiesProducer and Gatherer) and the total flow for the period redetermined in accordance with the provisions of Section 10.5. If the period of error condition cannot be determined or agreed upon between the PartiesProducer and Gatherer, such correction shall be made over a period extending over the last one half of the time elapsed since the date of the prior test revealing the two percent [***]% error (2%) errorbut not to exceed [***] months). (c) If, during any test of any Measurement Facilities, an adjustment or calibration meter proving error is found which results in an incremental adjustment to the calculated hourly flow rate which does not exceed two percent (2%) [***]% of the adjusted flow rate, all prior recordings and electronic flow computer data shall be considered to be accurate for volume quantity determination purpose.

Appears in 2 contracts

Samples: Crude Oil Gathering Agreement (Rattler Midstream Lp), Crude Oil Gathering Agreement (Rattler Midstream Lp)

AutoNDA by SimpleDocs

Measurement Accuracy Verification. (a) Each Party shall verify the accuracy of all Measurement Facilities or other equipment or facilities used in measuring or checking the measurement of volumes of Fresh Water or Produced Water under this Agreement owned by such Party no less frequently than twice quarterly. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once per yearMonth, unless a special test is requested pursuant to Section 10.410.5. (b) If, during any test of such the Measuring Facilities, an adjustment or calibration error is found which results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for the period redetermined in accordance with the provisions of Section 10.510.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be made over a period extending over the last one half of the time elapsed since the date of the prior test revealing the two percent (2%) error. (c) If, during any test of any Measurement Facilities, an adjustment or calibration error is found which results in an incremental adjustment to the calculated hourly flow rate which does not exceed two percent (2%) of the adjusted flow rate, all prior recordings and electronic flow computer data shall be considered to be accurate for volume determination purpose.

Appears in 1 contract

Samples: Water Services Agreement (ANTERO RESOURCES Corp)