Membership Content Sample Clauses

Membership Content. 10.1 A Member may submit content to sites supported by Xxxxxxxxxx.xxx, such as online notice boards, forums and feedback, without restriction. Member acknowledges that Xxxxxxxxxx.xxx may edit, revoke, and use such messages at any time the user uses the content fields. 10.2 Members have to make sure that the content displayed is not illegal, is not a copyright infringement, does not contain any crime or offense, and there is no limit to the display of any content.
AutoNDA by SimpleDocs
Membership Content. A Member may submit content to sites supported by Xxxx-xxx.xxx, such as online notice boards, forums and feedback, without restriction. Member acknowledges that Xxxx-xxx.xxx may edit, revoke, and use such messages at any time the user uses the content fields.

Related to Membership Content

  • Membership Information The District shall take all reasonable and lawful steps to safeguard the privacy of CSEA members’ personal information, including but not limited to members Social Security Numbers, personal addresses, personal phone number, personal cellular phone number and status as a union member. The District shall take all reasonable and lawful steps to protect employees personal information in response to Public Records Act requests. The District shall use its best efforts to filter out outsiders’ emails to work email address that interfere with and/or disrupt employees work.

  • Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety

  • Membership Dues Association membership dues, as explicitly approved by the Trustees;

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.

  • Customer Content As part of the Services provided under this Agreement, Customer Data will be stored and processed in the data center region specified in the applicable Ordering Document. Axway shall not access Customer Content except in response to support or technical issues where Customer provides Axway with prior Customer’s written authorization required to access such Customer Content. Axway is not responsible for unauthorized access, alteration, theft or destruction of Customer Content arising from Customer’s own or its authorized users’ actions or omissions in contravention of the Documentation. Customer’s ability to recover any lost data resulting from Axway’s misconduct is limited to restoration by Axway from the most recent back-up.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Partnership Name The name of the Partnership is “OZ Management LP.” The name of the Partnership may be changed from time to time by the General Partner.

  • Sub-loop Elements 2.8.1 Where facilities permit, BellSouth shall offer access to its Unbundled Sub-Loop (USL) elements as specified herein.

  • Condominiums/Planned Unit Developments If the Mortgaged Property is a condominium unit or a planned unit development (other than a de minimis planned unit development) such condominium or planned unit development project such Mortgage Loan was originated in accordance with, and the Mortgaged Property meets the guidelines set forth in the Originator's Underwriting Guidelines;

  • Shareholder Internet Services The Transfer Agent shall provide internet access to the Fund’s shareholders through a designated web site (“Shareholder Internet Services”), which will be accessed by the Fund’s shareholders via a link on the Fund’s web site. The Shareholder Internet Services will be provided pursuant to established procedures and will allow shareholders to view their account information and perform certain on-line transaction request capabilities. The Shareholder Internet Services shall be provided at no additional charge, other than the transaction fees currently being charged for the different transactions as described on the Fee Schedule. The Transfer Agent reserves the right to charge a fee for this service in the future.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!