North Booster Pump Station Upgrades Sample Clauses

North Booster Pump Station Upgrades. Option A is the selected approach for the north booster pump station upgrades ECM measurement and verification plan and performance assurance. This ECM includes the addition of two pump assemblies and two VFDs to modulate the motor speed to maintain water level in the water tower. The energy analysis parameters used to verify savings and assure performance are: M&V Option Parameters BASELINE POST-INSTALLATION Motor speed % Actual speed Stipulated Motor Amperage Instantaneous amperage reading Calculated based on motor speed ratio and affinity laws Motor Voltage Instantaneous voltage reading Stipulated, same as baseline Motor Power Factor Name plate data Name plate data Hours of Operation Stipulated Stipulated Water Losses Stipulated Stipulated Energy Consumption Calculated Calculated Demand Consumption Calculated Calculated Water Consumption Calculated Calculated Energy Rate Stipulated rate schedule Stipulated rate schedule Demand Rate Stipulated rate schedule Stipulated rate schedule Water Rate Stipulated rate schedule Stipulated rate schedule To validate the estimated savings of the equipment after the installation is complete, ESG will measure the following: - Data log the system amperage over a two-week period to verify it is working within the stipulated parameters. The information obtained will be used to verify the savings as shown in savings calculations for the north booster pump station upgrades ECM in Exhibit BAttachment 1. To assure the performance of the installed equipment ESG will: - Validate installed equipment and control sequences to meet specifications. - Validate installed equipment and control sequences to operate and perform as specified.
AutoNDA by SimpleDocs

Related to North Booster Pump Station Upgrades

  • Provisioning of High Frequency Spectrum and Splitter Space 3.2.1 BellSouth will provide <<customer_name>> with access to the High Frequency Spectrum as follows:

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • Purpose of Interconnection Facilities Except as may be required by Applicable Laws and Regulations, or as otherwise agreed to among the Parties, the Interconnection Facilities shall be constructed for the sole purpose of interconnecting the Large Generating Facility to the Participating TO’s Transmission System and shall be used for no other purpose.

  • Mid Span Fiber Meet a. The Parties may interconnect at a Mid Span Fiber Meet subject to the following terms and conditions:

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Network Resource Interconnection Service (check if selected)

  • Energy Resource Interconnection Service (ER Interconnection Service).

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!